8
Changing the light bulb
Disconnect the machine from the power supply by removing
the plug from the main socket!
Replace bulb with same type rated 10 watts (110-120V) or 15 watts
(220-240V).
-
Loosen screw (A) as illustrated. (1)
-
Remove the cover (B).
-
Turn the bulb half a rotation counter clock-wise (C) (2) and
remove the bulb. Push the new bulb upward into the holder as
far as it will go and turn it half a rotation in a clock-wise direction
until it held fi rmly.
-
Replace the cover and tighten screw.
Should there be any problem, ask your authorized Pfaff dealer for