63
33. Adjustment of bobbin case position finger
Requirement:
The clearance between the position finger and the bottom of the groove in the bobbin case base must be
0.7 mm.
Check:
z
It must be possible to insert clearance gauge (00-880133-01) with ease but without play between the
position finger and the bottom of the groove in the bobbin case base (fig. 68).
Adjustment:
z
Loosen the two screws 114.
z
Insert clearance gauge.
z
Press bobbin case position finger 113 against the gauge at an angle of 90 degrees.
z
Tighten the two screws 114.
Cross-check:
z
As described under "Check".
Содержание select 1520
Страница 1: ...Service Manual 1st Release August 2001 ...
Страница 2: ......
Страница 14: ...12 Notes ...
Страница 17: ...15 ...
Страница 19: ...17 ...
Страница 23: ...21 ...
Страница 25: ...23 ...
Страница 31: ...29 Notes ...
Страница 35: ...33 ...
Страница 41: ...39 Cross check z As described under Check ...
Страница 43: ...41 Notes ...
Страница 45: ...43 ...
Страница 47: ...45 ...
Страница 53: ...51 ...
Страница 59: ...57 Cross check z Carry out a visual check at straight and zigzag stitch settings ...
Страница 63: ...61 ...
Страница 67: ...65 ...
Страница 71: ...69 ...
Страница 73: ...71 ...
Страница 79: ...77 ...
Страница 81: ...79 ...
Страница 83: ...81 ...
Страница 85: ...83 ...
Страница 87: ...85 ...
Страница 89: ...87 ...
Страница 91: ...89 ...
Страница 100: ...98 ...
Страница 102: ...100 Notes ...
Страница 103: ...101 Notes ...
Страница 104: ...102 Notes ...
Страница 105: ...103 Notes ...