19
Controls
Key
3
:
Needle position change
This button can have the
following functions
assigned depending on the drive
system implemented and by way of changes to the parameter values:
P74 ED-L
PF 321
Parameter
Function
Parameter
Function
695
0 = Off
1 = needle raised without trimming
2 = needle position change (standard)
3 = single stitch
4 = single stitch in reverse
5 = moving forwards to needle
position step by step
6 = programmable tack on / off
842
0 = Function off
01 = Needle up without trimming
02 = Change needle position (standard)
03 = Single stitch
20 = Step-by-step approach to a
needle position forward
95 = Offset multi-backtack
96 = Backtack suppression (all autom.
backtack deactivated)
97 = Single stitch reverse
98 = Not used
Key
4
:
Calling up the pre-selected top feed lift
.
(Diode on = high lift, diode off = low lift)..
This button can have the
following functions
assigned depending on the drive
system implemented and by way of changes to the parameter values:
P74 ED-L
PF 321
Parameter
Function
Parameter
Function
401
0 = Off
1 = when key pressed constant
second stroke (standard)
2 = second stroke only as long as key
pressed
If this key is operated, the second
voltage is switched on
This function can be switched off un-
der Parameter 764
843
0 = Off
01 = With button pressed constantly,
2nd lift (standard)
02 = 2nd lift only while button is
pressed
14 = Stroke adjustment (Flip Flop 1)
with speed limit N10
(Parameter 137 must be set to "On"
Key
5
:
Bartack suppression for one bartack
.
This button can have the
following functions
assigned depending on the drive
system implemented and by way of changes to the parameter values:
P74 ED-L
PF 321
Parameter
Function
Parameter
Function
780
0 = Off
1 = tack inversion once (standard)
2 = tack suppression (all tacks
switched off)
3 = reverse move to needle position
step by step
4 = edge trimmer on / off
5 = programmable tack on / off
844
17 = Backtack inversion, single
(standard)
21 = Step-by-step approach to a
needle position reverse
95 = Offset multi-backtack
96 = Backtack suppression
(all autom. backtack deactivated)
97 = Single stitch reverse
98 = Not used
Содержание PowerLine 2235