(E)
6 mm
(A)
(B)
(F)
(G)
104 72 63-26
11
Adjustment of the presser bar height and alignment
Requirement
When the presser foot (A) is raised, the distance between the presser foot (A) and needle plate (B) should
be 5.7–6.3 mm.
Check
• Raise the presser foot.
• Place a block 6 mm thick under the presser foot and lower the presser foot lifter.
• The distance between the presser foot (A) and needle plate (B) should be 5.7–6.3 mm.
Adjustment
• Remove the face plate and needle.
• Raise the presser foot.
• Place a block 6 mm thick under the presser foot and lower the presser foot lifter.
• Pass the Allen key (C) through the hole (D) of the supporter.
• Loosen the hexagon socket screw (E).
• Adjust the distance between the zigzag foot (A) and needle plate (B).
• Raise the presser foot lifter and tighten the setscrew (E) fi rmly.
• Check if the presser foot is paralleled with the feed dog (F) as shown below (G).
If not, loosen the hexagon socket screw (E), and adjust the direction.
• Attach the face plate.