Adjustment
11 - 30
11
.09.02
Basic setting of the actuating lever
Requirement
1. The spherical head
1
should be positioned in the centre of the elongated hole of actuating
lever
5
.
2. When the needle is positioned 0.8 mm after t.d.c., the actuating lever
5
should be hori-
zontal.
●
Adjust the spherical head
1
(screw
2
) in accordance with
requirement 1.
●
Adjust lever
3
(screw
4
) in accordance with
requirement 2.
74
-042
4
3
74-047
5
2
1
Fig. 11 - 29