Adjustment
14 - 34
600
603
Connect outputs
With this function the outlets can be
connected. "OUT" shows the outlet
selected (1-16). Under "VAL" the
selected output is set (S) with the
plus/minus key (+), and reset (R) with
the plus/minus key. Interlocks are
checked. Non-assigned outlets are not
connected.
OUT
VAL
1
S/R
Solenoid for work
clamp open
2
S/R
3
S/R
Solenoid for
thread trimming
4
S/R
5
S/R
6
S/R
Program outlet
7
S/R
Program outlet
8
S/R
9
S/R
10
S/R
11
S/R
12
S/R
13
S/R
14
S/R
15
S/R
16
S/R
604
Move stepping motors
The stepping motors SM1 (X-axis) and
SM2 (Y-axis) are moved individually
with the respective plus/minus keys.
Interlocks are not checked.
605
Turn sewing motor
The sewing motor can be operated
with a selectable set speed by
pressing the pedal. After the sewing
motor has been started, the current
speed is also displayed.
606
Thread trimming sequence
The sequence for a complete thread
trimming cycle is started with the
plus/minus key (+) below CUT and
below THR.
Group
Parameter
Description
Setting
Set value
range