Adjustment
12 - 13
12
.05.11
Presser foot height
Requirement
At the bottom of its stroke, the presser foot should be at a distance of
approx. 1 mm
from
the needle plate.
Fig. 12 - 12
●
Adjust presser foot
1
(screw
2
) in accordance with the
requirement.
For very thick materials the distance from the needle plate can be increased to
reduce the operating noise of the machine.
96
-038
96-029
2
1
96-039
1 mm