TECHNICAL DETAILS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
TECHNICAL DATA 

 

Nominal output kW 

4.5 

Range rating kW 

4-5 

Heating area square metres 

10-90 

 

Wood 

Ancit 

Average combustion gas temp C 

272  

262 

Efficiency Net 

78.2%  

78.9% 

CO% @ 13% O2 

0.77%  

0.2% 

Fuel consumption kg/hr 

1.3 

0.71 

Weight kg 

55 

Содержание BOHEMIA X 40

Страница 1: ...n an open fire avoiding the wasteful draughts normally associated with that type of appliance Burning wood is the natural way to store the sun s energy to then be released in a carbon neutral process to heat your house when the need is most On a cold winters night there is nothing to beat the release of heat and flame in a stove to raise the spirit The preparation and burning of wood as a fuel in ...

Страница 2: ...ve RECOMMENDED FUELS The recommended fuels that can be burnt on these stoves are dry seasoned wood logs and fuel that are Authorised for use in Smoke Control Areas eg ancit Correct firing provides optimal heat output and maximum economy At the same time correct firing prevents environmental damage in the form of smoke and malodorous fumes and also reduces the risk of chimney fires Well seasoned wo...

Страница 3: ...condary and tertiary combustion It is important that the firebox temperature is maintained at a high level as this also aids complete combustion For example when first lighting a stove it is important to get it really hot before closing the burning rate down The firebox temperature should reach 400 C which equates to approximately 250 C at the flue pipe The Bohemia X 40 inset stove is designed and...

Страница 4: ...w clean because the secondary air washes over the glass For woodburning it is an advantage always to leave some ash lying in the bottom of the combustion chamber Take care when emptying the ash pan as cinders can continue to burn in the ash for long periods of time Only dispose of ashes when cold NOTE It is always advisable to leave the top air control open to allow the stove to operate to optimum...

Страница 5: ...perature paint PART II INSTALLATION INSTRUCTIONS for UK excluding Scotland where local Building regulations must be conformed to It is essential that the installation is carried out by an experienced and competent installer who is HETAS registered see www hetas co uk Under England Wales Building Regulations it is a legal requirement that the stove is either installed by a competent person which is...

Страница 6: ...mm or preferably 1metre away from the stove or flue pipe THE FOLLOWING ITEMS ARE INCLUDED WITH THE STOVE A pair of leather gloves for operation of door handle and air sliders flue collar and door handle and catch assembly ashpan and ashpan handle DOOR HANDLE AND CATCH ASSEMBLY Handle Bush Door Bush Catch Washer Screw HEARTH The fireplace and hearth should conform to at least the minimum requiremen...

Страница 7: ...he stove allowing for installations where the collar needs to be further back Bohemia offset flue extension INSTALLING THE STOVE The flue outlet can be attached to a suitable flue pipe and liner when required and left suspended in the chimney for connection to the firebox after installation of the firebox The Bohemia inset is designed to fit against the chairbrick with a small gap that should be f...

Страница 8: ...e Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is use...

Страница 9: ...ference Pevex10004 AH ver2 Date June 2011 Appendix B TECHNICAL DETAILS TECHNICAL DATA Nominal output kW 4 5 Range rating kW 4 5 Heating area square metres 10 90 Wood Ancit Average combustion gas temp C 272 262 Efficiency Net 78 2 78 9 CO 13 O2 0 77 0 2 Fuel consumption kg hr 1 3 0 71 Weight kg 55 ...

Страница 10: ... Illustrative guide to installing in standard fireplace showing Inset with flue pipe connection Showing Inset with flue flaunched into flue gather connection Fix firmly to chair brick with fixing bolts not supplied Remove side and rear bricks in stove to access predrilled holes Chair brick Skamolex Blue calcium silicate board cut and shaped to form heat insulator or rockwool insulation Weak mix ve...

Отзывы: