background image

 

GUARANTEE 
This product is guaranteed against defects in material and workmanship for a period of one year from the date of purchase. In 
order for the guarantee to be granted, a proof of purchase (normally the original invoice/receipt) is required and the serial 
number label must not be removed from the product. Pettersson Elektronik AB, Sweden (“Pettersson”) will repair or replace 
the product if it proves to be defective during the guarantee period, provided it is returned to Pettersson. No other guarantee is 
expressed or implied.  
 
This product does not contain any user-serviceable parts. Do not open it and always refer servicing to the manufacturer or any 
other party approved by the manufacturer.  
 
The guarantee covers none of the following: 

 

1. Damage to the product resulting from abuse and misuse, including but not limited to (a) the failure to use this product for 
its normal purpose or in accordance with Pettersson’s instructions on the proper use and maintenance of this product and (b) 
the installation or the use of this product in a manner inconsistent with the technical or safety standards in force in the country 
where the product is used. 

 

2. Damage to the product resulting from non-authorized modifications made to the product.  

 

3. Repairs done by non-authorized technicians. 

 

4. Accidents or similar causes beyond the control of Pettersson, including but not limited to lightning, water, fire and public 
disturbances. 

 
LIMITATION OF LIABILITIES 
In no event shall Pettersson be liable for any special, incidental or consequential damages of any nature including, but not 
limited to, damages resulting from loss of profit or revenue, recall costs, claims for service interruptions or failure to supply 
downtime, testing, installation or removal costs, costs of substitute products, property damage, personal injury, death or legal 
expenses. The customer's recovery from Pettersson for any claim shall not exceed the purchase price paid by the customer for 
the goods, irrespective of the nature of the claim, whether in warrant, contract or otherwise. The customer shall indemnify, 
defend and hold Pettersson harmless from any claims brought by any party regarding products supplied by Pettersson and 
incorporated into the customer’s product.  

 

Pettersson assumes no responsibility for any damage or loss resulting from the use of this manual. 

 

Pettersson assumes no responsibility for any loss or claims by third parties which may arise through the use of the D500X. 

 

Pettersson assumes no responsibility for any damage or loss caused by deletion of data as a result of malfunction, repairs or 
battery replacement. Be sure to back up all important data on other media to protect against its loss. 

 

PRODUCT SAFETY NOTICE AND RESTRICTIONS 
This product is intended for commercial use only. Products sold by Pettersson are not designed, intended or authorized for 
use in life support, life sustaining, human implantable, nuclear facilities, flight control systems, or other applications in which 
the failure of such products could result in personal injury, loss of life or catastrophic property damage. If the customer uses 
or sells the products for use in any such applications: (1) the customer acknowledges that such use or sale is at the customer's 
sole risk; (2) the customer agrees that Pettersson is not liable, in whole or in part, for any claim or damage arising from such 
use; and (3) the customer agrees to indemnify, defend and hold Pettersson harmless from and against any and all claims, 
damages, losses, costs, expenses and liabilities arising out of or in connection with such use or sale. 
 
Windows is a registered trademark of Microsoft Corporation. 
 
CompactFlash is a registered trademark of SanDisk Corporation. 
 
Other company, product and service names mentioned in this manual, may be trademarks of others.

 

 
 

Specifications are subject to change without notice. 

 
 
 

©

 

Pettersson Elektronik AB, 2014 

May 2014

Содержание D500X

Страница 1: ...o pre trigger i e the recording starts as the sound exceeds the chosen threshold level but both pre and post trigger functions are available in the standard not low power mode Some of the features of...

Страница 2: ...customer s recovery from Pettersson for any claim shall not exceed the purchase price paid by the customer for the goods irrespective of the nature of the claim whether in warrant contract or otherwi...

Страница 3: ...eate and file modified time in files changed to better represent the true time If the power is switched off or otherwise fails while the detector is in the Automatic Recording mode the detector will a...

Страница 4: ...key is used to start recording or to enter the automatic recording mode depending on which mode was chosen The ON OFF key is used to switch the detector on off or to exit the sleep mode It is also use...

Страница 5: ...erview Battery holders for 2 x 2 AA cells Built in electret microphone External microphone jack External power jack 5 5 8 V DC External trigger jack Power switch to select external or internal batteri...

Страница 6: ...NPUT GAIN 45 TRIG LEV 36 INTERVAL 5 SAMP FREQ 500 PRETRIG 1 REC LEN 5 HP FILTER YES AUTOREC YES T SENSE VERY HIGH ENTER Use to switch between parameters and to change the values Press ENTER to save ch...

Страница 7: ...IN Press the 1 0 key and then ENTER to enter standby ENTER ENTER Only for automatic recordings Manual recordings will start immediately after pressing REC For more detailed information about the funct...

Страница 8: ...n Power switch is activated In order to constantly maintain power to the real time clock and some other parts of the detector a small lithium battery is incorporated in the detector After several year...

Страница 9: ...ds will appear This may take a few tens of seconds depending on the size and number of CF cards Press ENTER to continue to the D500X READY screen First adjust the Input Gain volume control by pressing...

Страница 10: ...ain should be adjusted to keep the dB indicator below its maximum reading The Trigger Level should be set to make the detector trigger start recording at the desired signal level As an aid to do that...

Страница 11: ...ry high 0 High 1 Medium 2 Low 3 Very low 4 Switching between different profiles is an easy and fast way to change the settings The D500X has ten fixed profiles and ten user profiles To select which on...

Страница 12: ...he plug connected to the External Trig input jack RECORDING SETTINGS The parameters in the recording settings menu are Input gain volume Trigger level Minimum time interval to the next recording The h...

Страница 13: ...e the left right arrow keys to move between hour minute and the up down keys to change the value To accept and save the changes press ENTER If the Relative Timer is selected the calculated sunset and...

Страница 14: ...GHTNESS The MODE parameter determines in which situations the display is on When the detector is left unattended there is no need to have the display on at all while in other situations it may be bett...

Страница 15: ...ries If the battery voltage continues to decrease and falls below the shut down level the D500X will interrupt any recording in progress and put itself into sleep mode It then regularly monitors the b...

Страница 16: ...using the D500X Utility program The preparation stage has been eliminated in firmware version 2 so this version only requires that the CF cards used have been FAT32 formatted as described above Cards...

Страница 17: ...ing total space on all of the cards When the unit is set up for an automatic level triggered recording session all the CF cards should be newly formatted i e not contain any previous recordings The sw...

Страница 18: ...t the settings 3 Press F1 and set the display operating mode in the DISPLAY menu The recommended modes for automatic recording are OFF or AUTO OFF will keep the display off during the entire recording...

Страница 19: ...the indicators will flash once every second The detector will of course not respond to any sound as long as the current time is outside of the timer ON OFF interval 6 To end the recording session wake...

Страница 20: ...e warning level factory defaults 4 0 V for internal batteries and 4 7 V for external batteries This allows the battery to recover before the detector is allowed to resume recording which is important...

Страница 21: ...her installed the identification number is the serial number of the detector by default The metadata or parts of it can be retrieved by the D500X Utility program and the BatSound program Users upgradi...

Страница 22: ...me files with optional adding of date time prefix suffix to the file name Transfer D500X firmware upgrade files to a CF card The first step in using the D500X Utility is to select the drive that has t...

Страница 23: ...as a firmware upgrade card Follow the instructions on the display to perform the upgrade Recorded data files The Info command will display metadata from the selected file file name date time and firmw...

Страница 24: ...r defined prefix and or suffix can be added to the original file name Selecting multiple files will create copies of all files with time date prefix and suffix added This is useful to add identificati...

Страница 25: ...nal mic select input tie to pin B on plug to enable ext mic External batteries A Ground terminal B Positive terminal 5 5 8V The External DC jack accepts a DC voltage between 5 5 and 8 V 6 V recommende...

Страница 26: ...r protected in the meaning that it will withstand dust and a certain degree of humidity Heavy rain may result in water intrusion so under such conditions additional protection is recommended The prote...

Отзывы: