![Petsafe IF-100 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/petsafe/if-100/if-100_operation-manual_1532724019.webp)
Always remove your dog’s collar receiver before per-
forming any transmitter testing.
A. Transmitter Loop Test Procedure
The transmitter loop test procedure is use to determine
the cause of a "Boundary Wire Broken or
Disconnected" alarm indication. You will need a short 6-
5. Transmitter status/alarm priori-
ty sequence.
Collar Receiver Problems:
1. Collar Receiver does not
appear to be operating in con-
tainment field area.
2. Collar Receiver is not taking a
charge.
3. Receiver is not working and
case is damaged or "chewed" by
dog.
3.If the green power light on the lightning protector is not illuminat-
ed, verify that the outlet is working properly by plugging in a
known working item such as a radio.
4.Unplug the lightning protector and plug the power adapter
directly into the 110-volt outlet.If the transmitter operates when
bypassing the lightning protector, contact Invisible Fence for a war-
ranty replacement lightning protector. Do not use the system until
a replacement lightning protector has been provided.
5.If possible, check the voltage of the power adapter using a digi-
tal multimeter. It should read greater than 24 volts AC.
Under multiple operating/fault status conditions, the operating/fault
alarm priority sequence is as follows:
1.Boundary wire broken or disconnected.
2. AC power disconnected operating on battery backup power.
3.Receiver charging.
4.Receiver charge reminder.
5.Backup batteries low.
Possible Solutions:
1. Verify the transmitter is turned on and the status light is solid
green.
2.Check the collar receiver for a green flashing indicator light.If
light is flashing red or there is no light, recharge battery. See
Section 5.B.4, page 13.
3.Perform the field width test of Section 4.G.3 page 11 using the
test light and determine if the test light is illuminating.
4.Perform System Test procedure to determine which component
is malfunctioning.Section 8.C. pg 20.
1.Check that the collar is proper positioned in the charging cradle
on top of the transmitter. When properly positioned the transmitter
status light will flash green and a high frequency charge tone will
be heard.
2.Check that the adapter and lightning protector are plugged in
and either the boundary loop wire or a short test loop wire is con-
nected.A loop wire must be connected for the charger to function.
Contact Invisible Fence
®
at 1-800-688-4364 to purchase a new
collar receiver.
Transmitter Problems:
Possible Solutions:
foot piece of green boundary wire with 3/8-inch of the
insulation stripped from both ends. Verify the transmitter
is plugged into lightning protector, the tra n s m i t t e r
POWER switch is ON, and all boundary wire connec-
tions at the lightning protector and transmitter are prop-
erly connected.If the status light is still flashing red and
the alarm is on, continue with the following steps.
19.