INSTALLATION
2
Section 2
page 2.5
RCP-48X
Installation
Figure 2–5 Terminating Cable Runs
2.7 Terminating Cable Runs
Each cable run should be terminated at the end of the run with a 120ý,
1/4 watt 5% resistor. The cable is terminated internally at the controller.
See Figure 2–5.
1. Uncrimp the black and red leads in position 1 and 3.
2. Insert the resistor ends into position 1 and position 3 along with the
black and red leads.
3. Crimp down using a screwdriver.
4. The shield wire remains in position 2.