Perun V2 Hybrid Скачать руководство пользователя страница 9

7.

 

Diagnostic system 

Perun V2 Hybrid has a diagnostic system that will help you find the source, should you encounter a 
problem. After the battery is connected, the unit undergoes a start-up check, to make sure replica is 
ready to work. Successful completion of this check is indicated by a short green blink of the LED. 

Problem and LED color

 

Description 

Disconnected 
motor/Diagnostic mode

 

 

Yellow, blinking 

This  not  only  provides  information  about  the  disconnection  of  the 
motor, but it is also a diagnostic mode for the trigger, selector, and 
sector  gear  switches.  With  the  motor  disconnected,  engaging  the 
switches will cause the LED to glow purple (trigger), green (selector), 
or  blue  (sector  gear)  for  a  moment.  This  can  be  used  for 
troubleshooting problems with the switchboard in the gearbox. 
 
Reconnecting the motor will restore normal function. 
 

Attention

: Motor check only takes place at start-up. A disconnection 

after the start-up will not be signaled!

 

Fuse activation

 

 

Red, continuous, or blinking 

Activation  of  the  fuse  with  a  distinction  between  a  short  circuit 
(continuous red) and gearbox jam (blinking red). In some situations, 
this distinction may not be correct, for instance, a gearbox jam may 
be incorrectly read as a short circuit and vice versa. 
 
Electronic fuse might as well be activated by parts combination, which 
draws too much current (e.g. high speed motor and gears). 
 
The  unit  will  start  functioning  normally  after  the  battery  is 
reconnected unless there still is a short circuit that will be detected at 
the next start-up. 

Gearbox cycle detection 
failure

 

 

Yellow and blue blinking 
alternately 

The unit did not receive information about cycle end from the sector 
gear  switch  and  stopped  firing  only  after  safety  time  limit  was 
exceeded. Check whether the gears or the sensors are not damaged 
and whether the sensors are properly engaged by the gears. 

Unit temperature is too high

 

 

Yellow and white blinking 
alternately 

Too high temperature of the unit (electronic board) was detected. It 
will not function again until it cools down, after which it will operate 
normally. 

Battery with too low voltage 
is connected

 

 

Yellow and teal blinking 
alternately 

Battery with voltage below  7V is connected. Change  the  battery to 
one with voltage between 7V and 17V. 

Battery with too high 
voltage is connected

 

 

Red and teal blinking 
alternately 

Battery  with  voltage  over  17V  is  connected.  The  battery  must  be 
immediately  disconnected,  as  it  can  cause  permanent  damage!

 

Change the battery to one with voltage between 7V and 17V. 

An external magnetic field 
was detected

 

 

Red and violet blinking 
alternately 

External magnetic field (originating not from the trigger magnet) was 
detected  by  the  trigger  sensors.  The  unit  will  be  blocked  until  the 
source of the magnetic field is not removed. 

Содержание V2 Hybrid

Страница 1: ...Adaptive trigger control allows switching from a very short trigger travel to a long one even in the field with almost any trigger including stock ones Reading this manual will help you fully exploit...

Страница 2: ...oxes see page 13 KWA ERG replicas are not compatible These are gearboxes that we tested for compatibility during the design process Please be advised that despite our best efforts to provide reliable...

Страница 3: ...Do not use excessive force though 3 Install the plastic magnet holder on the trigger as shown on the photo to the right When screwing the two halves of the holder together use only little force not to...

Страница 4: ...rking make sure that the magnet together with its plastic holder is on the trigger and it is placed correctly The correct polarization of the magnet which end of the magnet is pointing at the board is...

Страница 5: ...e trigger pull necessary to fire a shot longer than it would have been when left in the standard forward position When in normal semiautomatic mode the Perun Hybrid uses a progressive trigger activati...

Страница 6: ...nd auto No sound signal steady green light safe 1 short single signal and blink semi 2 5 short signals and blinks 2 5 round burst 1 long signal and blink auto AB Blue Active brake AB stops the motor a...

Страница 7: ...When the two stage trigger is enabled the binary trigger is automatically disabled No sound signal while LED blinks purple and teal alternately means that the binary trigger is disabled 1 signal indi...

Страница 8: ...further used and must be recharged Unit automatically detects number of cells in the battery and determines safe voltage range The need for battery replacement is signaled by short sound signals every...

Страница 9: ...ted by parts combination which draws too much current e g high speed motor and gears The unit will start functioning normally after the battery is reconnected unless there still is a short circuit tha...

Страница 10: ...most preferably with a T deans socket made by different manufacturer Battery and or the motor heat up very much The battery has too low capacity mAh and or C parameter Use a battery with higher capaci...

Страница 11: ...rtup this can activate the error Make sure the trigger can move freely and completely unobstructed Use stronger trigger spring When RoF reduction is enabled electronic fuse activates or the replica ju...

Страница 12: ...nge at this moment Selector switched to AUTO Red This should happen after the selector is switched to AUTO Selector switched to SEMI Blue This should happen after the selector is switched to SEMI Sele...

Страница 13: ...no components and paths are visible in the area you want to modify Krytac Remove the small knob on the right gearbox half near the contacts Make room for the sector gear LED leg by making a small dent...

Отзывы: