Switch 1

Intrinsic safety selection

Switch 2

Main alarm relay functioning mode

Switch 3

Maintaining of the memory of alarm,
only when you set the CO gas

Switch 4

Selecting OXYGEN mode

Deleting or disabling the probes

monitored gas type selection

Power terminal block

Signal terminal block

S1

S2

S3

1 2 3 4

external push-button

terminal block

2 - GENERAL DESCRIPTION OF THE CENTRAL UNIT

3

c)

ppm

Toxic gas

The letters

means when the connected probe detects

.

The letters

means when the connected probe detects

.

LEL

Explosive gas

d)

The timing symbol lights when the device is in warm up phase, at the same time its begins the count down.

The exchange of data of every connected probe is every about 4 seconds.

The numbers in the rectangle “1 2 3 “ are the probe connected.

b)

1)

During warm up the control unit is not able to detect the presence of gas.

LED

. It blinks for about 2 minutes (warm up time) when the mains power is supplied. When ready, the LED stays on

without blinking.

ON

2) BATTERY LED

. It lights up (fixed) when no mains power is present and the control unit is supplied by a 12Vdc battery.

It blinks when the battery is flat.

5) TEST BUTTON

. Pressing and holding down this button, you can obtain a gas leakage simulation. In order to perform this

operation no failures or alarms should be present.

4) OVER LOAD BATTERY LED

. If this Led turns on, it means the battery is not connected properly, or it has an anomalous

voltage absorption.

6) RESET BUTTON

. This button is pressed to clear all memories, or to restore the control unit after a failure.

8) 2nd Pre Alarm LED

. This LED will light up when the gas concentration level has reached 13% of LEL (EXPLOSIVE GAS) or

200 ppm (TOXIC GAS) and the

relay contact is closed. The buzzer will issue a low frequency sound.

2nd threshold

7) 1st Pre Alarm LED

. This LED will light up when the gas concentration level has reached 8% of LEL (EXPLOSIVE GAS) or 120

ppm (TOXIC GAS) and the

relay contact is closed. The relay disenergizes when the 13% of LEL, or 200ppm

threshold is exceeded.

1st threshold

9) MAIN ALARM LED

. This LED will light up when the gas concentration level has reached 20% of LEL (EXPLOSIVE GAS) or

300 ppm (TOXIC GAS) and the

relay contact is closed. The buzzer will issue a high frequency sound.

MAIN ALARM

The relay disenergizes when dropping below the 13% of LEL, or 200ppm, threshold.

11) DISPLAY.

The display below is represented with all its segments and indications.

10) FAULT LED

. This LED blinks when one of the connected probes is faulty, if there is an interruption in the cable connection, or

if an error was made during wiring. When this LED is blinking, the device is no longer capable of detecting. To reactivate the
device, the damaged probe must be repaired or disabled using the internal micro-switch (see

chapter 6) and then

the RESET button must be pressed.

page 10,

3) OVER LOAD PROBES LED

. If this LED turns on, it means there is a short circuit or high current absorption in the probes.

a)

The number on the display indicates the concentration of gas detected.

c

000

a

d

LEL
ppm

1 2 3

b

Содержание 1GA300M

Страница 1: ... versatile and reliable for example by using a series of microswitches it is possible to In addition to the alarm signal light it is fitted with an internal buzzer for acoustic signals The IP44 external structure was designed for installations on walls or on electrical panels by means of special brackets 2 Maintenance TEST With special arrangements you can enable the function of exclusion of the g...

Страница 2: ...egulations The manufacturer declines any liability for the use of products subject to special environmental and or installation standards The installation of the unit its ordinary and extraordinary maintenance once a year and its out of service removal at the end of the functional life guaranteed by the manufacturer must be carried out by authorized or specialized personnel DISPOSALOFELECTRICAL EL...

Страница 3: ... voltage absorption 6 RESET BUTTON This button is pressed to clear all memories or to restore the control unit after a failure 8 2nd Pre Alarm LED This LED will light up when the gas concentration level has reached 13 of LEL EXPLOSIVE GAS or 200 ppm TOXIC GAS and the relay contact is closed The buzzer will issue a low frequency sound 2nd threshold 7 1st Pre Alarm LED This LED will light up when th...

Страница 4: ...eferring to oxygen 00LEL 20 6 300ppm 20LEL FAU 000LEL ppm 1 2 3 Identification of the Sensors probes A row of LEDs numbered called PROBES has been fitted on the device These LEDs are lit with a 4 seconds frequency representing the connected probes and indicate the probe being read on the display from 1 to 3 and In case of alarm the LED that represents the probe stops for about 15 seconds This is d...

Страница 5: ...mory when the gas CO is selected S3 switch group reserved to the probe N 3 Legend setting switches S1 switch group reserved to the probe N 1 S2 switch group reserved to the probe N 2 Diagram of the terminal block relay PLEASE NOTE All relays are free of voltage Power supply 230 VAC PH N 4 5 6 7 8 9 10 11 12 C NC NO C NC NO C NC NO C NC NO Fault 1stthreshold 2ndthreshold Main Alarm Connection of pr...

Страница 6: ...11 12 Power supply 230 VAC C NC NO C NC NO C NC NO C NC NO Control unit power supply and connection of a solenoid valve with sirens to 12 VDC trough an and recharge battery external power supply It s not possible to connect directly solenoid valves or sirens 12V dc to the control unit Power supply 230 12V Diode 1N 5406 3 2 1 Probe 1 3 2 1 Probe 2 3 2 1 Probe 3 Solenoid valve GAS and Sirens 12 VDC ...

Страница 7: ...o switches on the control unit you can to activate or to deactivate 3 Zones In this case we will proceed to disable a probe to do this select the switch of the probe zone concerned In some installations you may need only one probe N B the microswitches are also used for switching off in case of failure Zon 1 Zon 2 Zon 3 e e e Micro switch to enable or to disable the sensor probe 1 Position ON enab...

Страница 8: ...tion this function becomes active only when the detection of Toxic Gases reading in ppm is selected In the position Continuous function the relay remains closed until the button is pressed ON RESET In the position Impulse function the relay remains closed for 5 seconds and then disenergizes afterwards OFF Switch 2 Functioning Mode of main alarm relay Note the general alarm relay MAIN ALARM in the ...

Страница 9: ...NG OF THE SENSORS PROBES Itis importanttonotethattheremoteprobesshouldbeinstalledaccordingtothefollowingrestrictions Atleastonceayearmakeamoreaccuratecheckbyaspecialisttechnician Theprobesbeingtakenoutofserviceafter5yearsfrominstallationmustbecarriedoutbyqualifiedpersonnel The user periodically every 6 months must perform a check of the operation of the control unit by spraying a suitable test gas...

Страница 10: ...k that the 230VAC mains power is correctly connected If the device does not start up Check that at the terminals 3 and 5 6 7 is present a voltage from a minimum of 0 8 VDC at a maximum of 1 1 VDC Check that the voltage at the terminals 3 4 is greater than 11 VDC and less than 25 VDC If the Over Load Probe LED lights up If the Over Load Battery LED lights up Check that the power polarity has not be...

Страница 11: ...es when outside fire department distributors etc Close the main gas tap CH4 or the LPG cylinder tap If the alarm stops its cause must be found and the relevant consequent measures taken If you have the following symptoms vomiting sleepiness or else go to the closest first aid station and inform the operators that you could have been poisoned by Carbon Monoxide or by an excess or deficiency of oxyg...

Отзывы: