background image

connection alterations or when changing 
input sources. The reason for this precaution 
is to protect your loudspeakers against bursts 
of very high powered signals from high level 
sources such as a CD player or whilst tuning 
the ETR between stations when high level 
spurious noise can be present. Situations can 
arise when playing a low output cassette with 
a fairly high volume control setting then 
switching to CD or Tuner where a high level 
of signal may be present at the source input 
sockets. The resulting burst of high power 
may damage your speakers or cause 
damage in some power amplifiers. 
 
- Make all connections logically and care-
fully, checking that you are maintaining 
channel integrity. 
 
- Install your Tuner close enough to your  
control amplifier to avoid stretching or 
extending your interconnect leads. 
 
- Keep your interconnect cables and antenna  
leads away from all mains / line cables and  
speaker leads. 
 

MAINS / LINE VOLTAGE CHANGE 

 
It is important that the ETR be operated from 
the correct mains/line voltage. This unit is 
factory set for the voltage applicable to the 
original country of destination. The correct 
operating voltage is indicated by the voltage 
label on the rear panel 

(

see section MAINS 

LINE VOLTAGE LABEL). 
 
The ETR will operate satisfactorily within a 
voltage variation of up to +/- 5%  of that 
voltage at which the unit has been set. 
If you require the voltage setting to be 
altered, e.g. relocation to another area, city or 
country, or extraordinarily high or low 
voltages, contact your Perreaux dealer. This 

modification can only be performed by 
qualified service personnel. 
 
 
 
 

NOTE : Always ensure this unit is 
disconnected from the Mains/Line supply 
before any covers are removed
 

 
Any modifications to the mains/line voltage 
setting within your Perreaux product may only 
be carried out by a approved Perreaux 
service agent.  Failure to recognise this 
warning will void any warranty.   

 

MAINS / LINE FUSE 

 
The Perreaux ETR is equipped with internal 
mains/line fuses which are not user 
serviceable. These fuses do not usually blow 
without a reason. Any doubts about fuse 
failure should be conveyed directly to your 
Perreaux dealer. 
 

NOTE: Always ensure your ETR is 
disconnected from the mains/line supply if 
attempting to change the mains/line fuse. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 