background image

 

 

10 

4

4

4

4

 

Rear Panel Functions 

 

Caution!  Please make all changes at minimum volume setting.  Only increase the

volume after the connections have been made. 

 

  Digital Output 

Using a standard 75

Ω

 coax digital cable with RCA termination, connect the

digital output to the coax digital input on the external D/A converter. 
These high quality gold plated sockets are highly conductive, corrosion resistant,
and provide less potential for corrosion induced distortion. 

Refer to Chapter 13 “Specifications” for more details. 

  Analog Output 

Standard single-ended outputs (RCA) supplying analog signals to the source
inputs of an audio preamplifier, integrated amplifier or receiver. 

Using quality audio interconnect cables, connect the left channel output of the
ECD2 to the left channel input on the preamplifier or other component and the
right channel output to the right channel input on the preamplifier or other
component. 

Refer to Chapter 13 “Specifications” for more details. 

  Serial Number 

The serial number is unique to your ECD2.  Please record this number and store
it in a safe place.  For any service related enquiry, please be prepared to quote
the product serial number to Perreaux personnel or their service representative. 

  Input Voltage and Fuse Rating 

Input Voltage  

It is important that the ECD2 be operated from the correct AC mains voltage.
This unit is factory set for the voltage applicable to the original country of
destination. 

Содержание ECD2

Страница 1: ...ECD2 ECD2 ECD2 ECD2 Compact Disc Player Owners Manual...

Страница 2: ...change products or specifications detailed herein at any time without notice and does not make any commitment to update the information contained herein No licenses to patents or other intellectual pr...

Страница 3: ...2 This page has intentionally been left blank...

Страница 4: ...estment in Perreaux Perreaux products are designed to provide the utmost in sonic realism and electronic reliability with a functional yet elegant appearance that reflects the care and craftsmanship a...

Страница 5: ...ratures The ECD2 should be connected to a mains power supply only of the type described in the operating instructions or as marked on the rear of the unit DO NOT disconnect the mains earth from the sy...

Страница 6: ...ns 8 4 4 4 4 Rear Panel Functions 10 5 5 5 5 Remote Control Functions 12 6 6 6 6 Special Design Philosophies 15 7 7 7 7 Special Design Features 17 8 8 8 8 Maximising System Potential 18 9 9 9 9 Care a...

Страница 7: ...the box Alternately the bottom tray and player could be tipped upside down and the bottom packaging removed If opened in this manner please ensure that you turn the contents over again Note Be very ca...

Страница 8: ...ier Note Try to keep all interconnect cables as far from loudspeaker cables as possible and well away from all AC mains leads Switch on ECD2 After checking the supply voltage compatibility with the vo...

Страница 9: ...t track displaying REPEAT 1 in the display Pressing a second time repeats the entire disc displaying REAPEAT ALL in the display Press a third time to cancel the REPEAT function Note The REPEAT functio...

Страница 10: ...beginning of the current track Pressing twice quickly in succession returns to the beginning of the previous track The new track number is shown in the display Button Pressing this button advances to...

Страница 11: ...io preamplifier integrated amplifier or receiver Using quality audio interconnect cables connect the left channel output of the ECD2 to the left channel input on the preamplifier or other component an...

Страница 12: ...s provided at the rear of the unit The AC cord set is removable allowing you to upgrade to a cord set of your preference Caution Prior to connection to the AC mains please check the voltage label on t...

Страница 13: ...yback in a specific order For example you could instruct the ECD2 to play track 6 followed by track 10 followed by track 2 To begin a program Insert a disc and close the drawer The ECD2 will read the...

Страница 14: ...always indicate the currently playing track even if above 16 The DIRECT ACCESS buttons may also be used to memorise tracks in PROGRAM mode Track Forward Track Backward These buttons are used to selec...

Страница 15: ...ion cancels any programmed selections Random This instructs the ECD2 to play tracks from the entire disc in random order Once all of the selections have been played once the disc will stop playing unl...

Страница 16: ...design perspective only The concept of less equating to more has been at the heart of all Perreaux audio designs for more than a quarter of a century Minimalist Electronics We wish to maximise the qu...

Страница 17: ...products on the planet We let form and function blend together in perfect harmony This surely is the essence of true minimalist utilisation Minimalism in a Wider Context John Pawson writes Clearly si...

Страница 18: ...tage ensuring the analog section is completely free from digital noise Dual 20 bit Burr Brown DAC The ECD2 s precision transport is backed up by Burr Brown s PCM1732 digital to analog converter featur...

Страница 19: ...istance at the lowest possible level If your amplifier is closer to one of your speakers than the other avoid coiling the longer lead as this can create inductance with the potential of reduced high f...

Страница 20: ...soft cloth If the dirt is not removed dip your cloth in a mild solution of soap and water squeeze excess moisture from it and then gently reapply to the surface Stubborn dirt may be removed by the ap...

Страница 21: ...will be repaired or replaced at our option without charge for either parts or labour The warranty does not apply to any unit that has been misused abused or altered Any unit that is not performing sat...

Страница 22: ...l Perreaux Industries Ltd PO Box 47 413 Ponsonby Auckland New Zealand E mail info perreaux com Alternatively complete the online Warranty Registration Form on our website www perreaux com 3 Year Exten...

Страница 23: ...must be employed to negate these effects on low level signal equipment Another good practice to adopt is to keep all signal leads away from power leads The practice of neatly tying excess leads togeth...

Страница 24: ...hen experiencing a problem such as one channel not working or a noise in one channel it is good practice to adopt a method of isolating the problem to a specific item or area This practice will assist...

Страница 25: ...swapping them at the amplifier output If the fault now appears in loudspeaker B then that loudspeaker lead is at fault go no further If the fault appears in loudspeaker A then loudspeaker leads are O...

Страница 26: ...t at a minimum volume setting Only increase the volume after the connections have been changed Should the fault prove to be in the amplifier it will be necessary to determine where the fault actually...

Страница 27: ...estore speaker cables to original connections Fault in loudspeaker B Swap amplifier source input channels Loudspeaker A at fault YES NO Loudspeaker cable at fault Fault in loudspeaker A Swap source ou...

Страница 28: ...In Brief Audio Section Analog Output Rated Output 2 0VRMS Output Impedance 100 Digital Output Rated Output 0 5Vp p Load Impedance 75 Frequency Response 20Hz to 20kHz 0 5dB Total Harmonic Distortion TH...

Страница 29: ...the coaxial digital interconnect Frequency Response 20Hz to 20kHz 0 5dB Describes the frequency range where the amplitude or strength of the output signal deviates from the source material by no more...

Страница 30: ...29 14 14 14 14 Physical Dimensions...

Страница 31: ...ails For more information please contact your Perreaux dealer or contact Perreaux Industries Ltd PO Box 47 413 Ponsonby Auckland New Zealand Ph 64 9 815 5452 Fax 64 9 815 5981 E mail info perreaux com...

Страница 32: ...31 Installation Notes...

Отзывы: