background image

4

ROHO MOSAIC Cushion Operation Manual

Warnings:

 

-

DO NOT use a product that is underinflated or overinflated, because 1) the product benefits will 
be reduced or eliminated, resulting in an increased risk to skin and other soft tissue, and 2) the 
individual may become unstable and vulnerable to falling. Carefully follow the instructions for 
inflation, placement and hand check. 

 

-

After setting up the cushion the first time, check inflation frequently, at least once a day. Follow the 

H

AND

 C

HECK

 

instructions. See the next page.

 

-

If the product does not appear to be holding air, or if you are not able to inflate or deflate the 
product, see 

T

ROUBLESHOOTING

. Immediately contact your equipment provider, distributor, or ROHO, 

Inc. if the problem persists. 

 

-

When possible, use the hook or loop fasteners to further secure the cushion to the seating surface.

Cushion Instructions: 

C

USHION

 I

NFLATION

 and 

C

OVER

 P

LACEMENT

Cushion Inflation:

1. Overinflate the cushion:

a.  Slide the hand pump nozzle over the 

inflation valve. Open the inflation valve. 

b.  Inflate the cushion until all of the air cells 

feel firm.

c.  Close the inflation valve and remove the 

hand pump.

2. Carefully follow the instructions for 

C

OVER

 

P

LACEMENT

.

Cover Placement:

Note: Keeping a cover on your cushion will help 
to protect the cushion components. A cover will 
also help to keep the air cells together, which 
may aid in slide board transfers. 

3. Place the cushion inside the cover:

a.  Unfold the cover.
b.  Insert the cushion.
c.  Close the zipper.

Note: When covered, the cushion should lie flat 
on the chair (non-skid material on the bottom).

4. Carefully follow the instructions for 

C

USHION

 

P

LACEMENT

 and 

H

AND

 C

HECK

. See the next page.

Back

Front

Heavy Duty Cover (COV-HD): 

The inflation valve 

should point toward the zipper.

Zipper

Inflation Valve

  

D A T E :

YYYY/MM/DD

S I Z E :

          i n c h e s :                       c e n t i m e t e r s :  

F I T S   C U S H I O N S :

REF

COV-HD1211

1R1211C, 1R1211HD, 

QS1211C, CS1211C,

1RHE2220C-SR, 2RHE2220C,

1R1211H-CH-XX, 1R1211M-CH-XX

23 x 20.25 x 4.25

58 x 51.5 x 10.5

Standard Cover: 

The corners of the cushion should be visible 

through the corner openings of the cover.

Back

Front

Zipper

Inflation Valve

Corner Opening (x4)

Close

Open

Carrying Handle

Содержание ROHO MOSAIC

Страница 1: ...be given to the user of this product Operator Individual or Caregiver Before using this product read the instructions and save for future reference s h a p e f i t t i n g t e c h n o l o g y ROHO MOSAIC Cushion Operation Manual ...

Страница 2: ...oting Storage Disposal and Recycling 6 Cleaning and Disinfecting 7 Product Specifications Limited Warranty 8 Español 9 Français 17 Deutsch 25 Italiano 33 Nederlands 41 Dansk 49 Svenska 57 Norsk 65 Suomi 73 Português 81 ROHO products may be covered by one or more U S and foreign patents and trademarks including ROHO shape fitting technology and MOSAIC 2017 ROHO Inc Rev 12 15 2017 ...

Страница 3: ...r It will NOT support you in water If you are unable to perform any tasks described in this manual seek assistance by contacting your clinician equipment provider distributor or ROHO Inc DO NOT expose the cushion to any source of high heat including heating pads Exposure to high heat will accelerate aging and damage the product the benefits provided by the cushion may be reduced or eliminated incr...

Страница 4: ...e carrying handle on the cover Using a pump cover or repair kit other than those provided by ROHO Inc may void the product warranty DO NOT modify the cushion or any components Doing so may result in damage to the product and will void the warranty Periodically check components for damage and replace if necessary See TROUBLESHOOTING To order replacement parts contact your equipment provider or ROHO...

Страница 5: ...over the inflation valve Open the inflation valve b Inflate the cushion until all of the air cells feel firm c Close the inflation valve and remove the hand pump 2 Carefully follow the instructions for COVER PLACEMENT Cover Placement Note Keeping a cover on your cushion will help to protect the cushion components A cover will also help to keep the air cells together which may aid in slide board tr...

Страница 6: ...inflation valve Warnings Make sure that there is at least in 1 5 cm of air supporting the individual s lowest bony prominences After setting up the cushion the first time check inflation frequently at least once a day Follow the Hand Check instructions above Close Open A sink down into the cushion and B float above the cushion base A B Proper Cushion Inflation Setting 1 1 5 cm 2 5 cm recommended d...

Страница 7: ...dual and the wheelchair Allow the individual at least one hour to adjust to the cushion The Cushion Slides on the Wheelchair Make sure the non skid bottom of the cushion cover is facing away from the individual Use directional labels on the cushion and on the cover to orient the cushion Use hook and loop fasteners to further secure the cushion to the wheelchair The Cushion is Stiff If the cushion ...

Страница 8: ...ning products that contain petroleum or organic solvents including acetone toluene Methyl Ethyl Ketone MEK naphtha dry cleaning fluid adhesive remover oil based lotions lanolin or phenolic based disinfectants ozone gas ultraviolet light cleaning methods To Clean the Cushion Remove the cover close valve s and place in a large sink Hand wash using mild liquid hand soap hand dishwashing liquid laundr...

Страница 9: ...ure the cushion in the chair Refer to cover care label for material content Sizing all measurements are approximate W D W x D in W x D cm MOSAIC 1616 16 x 16 41 5 x 41 5 MOSAIC 1618 16 x 18 41 5 x 46 5 MOSAIC 1717 17 x 17 44 0 x 44 0 MOSAIC 1816 18 x 16 46 5 x 41 5 MOSAIC 1818 18 x 18 46 5 x 46 5 MOSAIC 2018 20 x 18 51 5 x 46 5 Cell Height Range 2 3 in 6 5 7 5 cm Width W and Depth D measured edge ...

Отзывы: