ROHO DRY FLOATATION Mattress Overlay Operation Manual

Intended Use

The ROHO DRY FLOATATION Mattress Overlay System (Standard Overlay) and the ROHO DRY FLOATATION Bariatric Mattress Overlay System (Bariatric 

Overlay) are non-powered, air-filled, adjustable, zoned, reactive, full support surfaces that are intended to conform to an individual’s shape to provide skin/soft 

tissue and deep tissue injury protection and an environment to facilitate wound healing. ROHO mattress overlays must be used on top of standard hospital, 

nursing home, home care or consumer mattresses. There is no weight limit for the Standard Overlay or Bariatric Overlay, yet they must be properly sized to 

the bed mattress, and areas of the individual that require skin/soft tissue protection must be supported by the Standard Overlay or Bariatric Overlay.

An experienced clinician should determine whether the product is appropriate for the individual’s particular equipment needs. The product’s intended use 

statement alone should not be relied upon to make that determination.
The medical products featured in this document are intended to be only one part of an overall care regimen that includes all therapeutic equipment and 

interventions. An experienced clinician should identify this care regimen after evaluating the individual’s physical needs and overall medical condition.
A clinician should also evaluate for visual, reading, and cognitive impairment to determine the need for caregiver assistance or the need for other assistive 

technology, such as large-print instructions, to ensure proper product use. 

Important Safety Information

Warnings:

 - The product should be set up by your equipment provider or clinician.
 - While the product is in use, continue to follow all clinician 

recommendations for skin protection, including any schedule for 

regularly repositioning the individual.

 - The support surface products featured in this manual will function 

without side rails; however, side rails may be necessary for some 

individuals. The decision whether to use side rails should be made 

by the individual’s clinician and/or healthcare provider. If side rails are 

necessary for an individual, the following points should be considered by 

the individual in conjunction with his/her clinician or healthcare provider 

to reduce the risk of falling or entrapment.

 - If it has been determined that side rails are clinically indicated for an 

individual, knowledgeable and properly trained caregivers should 

identify and minimize any risks of entrapment in side rails.

 - If it has been determined that side rails are NOT clinically indicated for 

an individual, knowledgeable and properly trained caregivers should 

identify and minimize any risks of falling out of bed.

 - Whether side rails are used or not used, knowledgeable and properly 

trained caregivers should assess the need for devices or aids that will 

reduce the risk of falling out of bed or entrapment in side rails.

 - The overlay MUST be correctly sized to the bed mattress and to the 

individual. If the overlay is NOT correctly sized to the bed mattress and 

the individual, the product's benefits may be reduced or eliminated, 

increasing risk to skin and other soft tissue.

 -

Skin/soft tissue breakdown can occur due to a number of factors, 

which vary by individual. Check skin frequently, at least once a day. 

Redness, bruising, or darker areas (when compared to normal skin) 

may indicate superficial or deep tissue injury and should be addressed. 

If there is any discoloration to skin/soft tissue, STOP USE immediately. 

If the discoloration does not disappear within 30 minutes after disuse, 

immediately consult a clinician.

 - The cushioning products featured in this operation manual may introduce 

radiopacities and are therefore NOT recommended for use with x-rays. 

Radiopacities may interfere with diagnoses or surgical procedures that 

require radiographic images.

 -

DO NOT use the product as a water flotation device (e.g., a Life 

Preserver). It will NOT support you in water.

 - If you are unable to perform any tasks described in this manual, seek 

assistance by contacting your clinician, equipment provider, distributor, 

or Customer Support.

Warnings:

 -

DO NOT expose the product to high heat, open flames or hot ashes. 

Testing or certification claims, including for flammability, may no longer 

apply to this device when it is combined with other products or materials. 

Check testing and certification claims for all products used in combination 

with this device.

 - DO NOT use the product as a transfer surface. DO NOT reposition the 

product while it is in use.

 - The mattress overlay surface will acclimate to the surrounding temperature. 

Take appropriate precautions, especially when the overlay will contact 

unprotected skin.

Cautions:

 - Periodically, check the cover and components for damage and replace if 

necessary.

 - DO NOT use a pump, cover or repair kit other than those compatible with 

your product.

 - Changes in altitude may require adjustment to your product.
 - Keep the product away from sharp objects.
 -

If a product has been in temperatures less than 32°F / 0°C and exhibits 

unusual stiffness, allow the product to warm to room temperature, then 

open air valve(s). Roll and unroll the product until the material is soft and 

pliable again. Repeat Hand Check/Adjustment instructions before using.

 - DO NOT use any valve or air cell as a handle for carrying or pulling the 

product. Grasp the product by the base or the outside edges.

 - DO NOT allow your product to come into contact with oil-based lotions or 

lanolin. They may degrade the material.

 - Prolonged exposure to ozone may degrade the materials used in a 

neoprene product, affect the performance of the product, and void the 

product warranty.

Important Notes:

 -

An unoccupied product may appear to be underinflated (not enough air) 

even if it has been inflated and correctly adjusted for a specific individual. 

This is because the individual's body mass is not pushing down on the air 

cells. 

 -

CPR may be performed without deflating the product. A cardiac board is not 

necessary.

Содержание ROHO DRY FLOATATION Mattress Overlay

Страница 1: ...s h a p e f i t t i n g t e c h n o l o g y ROHO DRY FLOATATION Mattress Overlay Operation Manual ...

Страница 2: ......

Страница 3: ...er Support for previous versions of product information ROHO Inc is part of Permobil Seating and Positioning 2008 2021 Permobil Rev 2021 01 21 The following products are featured in this operation manual ROHO DRY FLOATATION Mattress Overlay System or Section Standard ROHO DRY FLOATATION Bariatric Mattress Overlay System or Section Warning Indicates that not following the specified procedure could ...

Страница 4: ...f bed or entrapment in side rails The overlay MUST be correctly sized to the bed mattress and to the individual If the overlay is NOT correctly sized to the bed mattress and the individual the product s benefits may be reduced or eliminated increasing risk to skin and other soft tissue Skin soft tissue breakdown can occur due to a number of factors which vary by individual Check skin frequently at...

Страница 5: ...dard Overlay Section Width x Length x Height 33 x 19 x 3 in 86 x 49 x 8 5 cm Weight 8 lb 3 6 kg Standard Overlay System 4 Sections Width x Length x Height 33 x 75 x 3 in 86 x 190 5 x 8 5 cm Weight 32 lb 14 4 kg Bariatric Overlay System 8 Sections Length x Height 75 x 3 in 190 5 x 8 5 cm Width Weight 39 in 100 5cm 36 5 lb 16 5kg 41 in 105 5cm 38 5 lb 17 4kg 54 in 138 5cm 47 5 lb 21 5kg 60 in 152 5c...

Страница 6: ...gs If you are using the Reusable Overlay Cover or the Overlay Enclosure Cover refer also to the instructions provided with the cover Warning Placing too many linens between the individual and the product will reduce its the effectiveness If needed the following items may be placed on top of the mattress overlay and the Reusable Overlay Cover or the Overlay Enclosure Cover One flat or contoured she...

Страница 7: ...riatric Overlay sections The overlay and the bed mattress are in a flat position All sections are aligned and snapped together See Placing the Overlay Any needed coverings are in place on the overlay See the Cover Guide 2 The individual should transfer onto the overlay The individual should be in their usual position lying on their back their side or other usual position Hand Check 3 Perform a Han...

Страница 8: ...ied product may appear to be underinflated not enough air even if it has been inflated and correctly adjusted for a specific individual This is because the individual s body mass is not pushing down on the air cells A component is damaged Contact Customer Support for a replacement Storage Transport Disposal and Recycling Storage and Transport Clean and disinfect the product before storing Open the...

Страница 9: ...uct abrasives steel wool scouring pads caustic automatic dishwasher detergents cleaning products that contain petroleum or organic solvents including acetone toluene Methyl Ethyl Ketone MEK naphtha dry cleaning fluid adhesive remover oil based lotions lanolin ozone gas ultraviolet light cleaning methods DO NOT expose to direct sunlight Rinse thoroughly Detergent residue may cause air cells to stic...

Страница 10: ...ogy Produktinformationen uppdateras efter behov aktuell produktinformation finns tillgänglig på permobilus com Kontakta kundtjänst för tidigare versioner av produktinformationen ROHO Inc ingår i Permobil Seating and Positioning 2008 2021 Permobil Rev 2021 01 21 Följande produkter beskrivs i denna bruksanvisning ROHO DRY FLOATATION madrassystem eller sektion standard ROHO DRY FLOATATION bariatrimad...

Страница 11: ...sårmadrass och patienten Om madrassen INTE har rätt storlek i förhållande till sängens resårmadrass och patienten kan fördelarna med produkten reduceras eller elimineras vilket ökar risken för huden och annan mjukvävnad Skador på hud mjukvävnad kan uppstå på grund av en rad faktorer som varierar för varje patient Undersök huden ofta minst en gång om dagen Rodnad blåmärken eller mörkare områden jäm...

Страница 12: ...a kundtjänst angående tillgängliga storlekar Madrassektion av standardtyp Bredd x längd x höjd 33 x 19 x 3 tum 86 x 49 x 8 5 cm Vikt 8 lb 3 6 kg Madrassystem av standardtyp 4 sektioner Bredd x längd x höjd 33 x 75 x 3 tum 86 x 190 5 x 8 5 cm Vikt 32 lb 14 4 kg Bariatrimadrassystem 8 sektioner Längd x höjd 75 x 3 tum 190 5 x 8 5 cm Bredd vikt 39 tum 100 5 cm 36 5 lb 16 5 kg 41 tum 105 5 cm 38 5 lb ...

Страница 13: ...läggs på madrassen Om du använder det återanvändbara madrassöverdraget eller det omslutande madrassöverdraget ska du även hänvisa till de instruktioner som medföljer överdraget Varning Om alltför mycket sänglinne placeras mellan patienten och produkten reduceras dess effektivitet Följande artiklar kan vid behov placeras ovanpå madrassen och det återanvändbara madrassöverdraget eller det omslutande...

Страница 14: ...ssektioner Madrassen och sängens resårmadrass ligger plant Alla sektioner är korrekt inriktade och hopknäppta Se Placera madrassen Eventuella överdrag som behövs är på plats på madrassen Se Vägledning om överdrag 2 Patienten ska lägga sig på madrassen Patienten bör ligga i sin vanliga position på rygg på sidan eller i annan normal position Manuell kontroll 3 Utför en manuell kontroll för att säker...

Страница 15: ... löst pumpad ej tillräckligt med luft fastän den har blåsts upp och justerats korrekt för en specifik patient Detta beror på att patientens kroppsmassa inte trycker ned luftkuddarna En komponent är skadad Kontakta kundtjänst för att skaffa reservdelar Förvaring transport avfallshantering och återvinning Förvaring och transport Rengör och desinficera produkten före förvaring Öppna uppblåsningsventi...

Страница 16: ...n skada produkten nötande produkter stålull skursvampar kaustiska tvättmedel för automatiska diskmaskiner rengöringsprodukter som innehåller petroleum eller organiska lösningsmedel inklusive aceton toluen metyletylketon MEK nafta kemtvättsvätska limborttagningsmedel oljebaserade lösningar lanolin ozongas rengöringsmetoder som använder sig av ultraviolett ljus Utsätt INTE produkten för direkt sollj...

Страница 17: ......

Страница 18: ...T20265 Rev 2021 01 21 Print Date Qty 1501 South 74th St Belleville IL 62223 USA permobilus com EUROPE Permobil Box 120 861 23 Timrå Sweden 46 60 59 59 00 permobil com ...

Отзывы: