perma STAR CONTROL - Quick Start Guide

1. Predefi ne installation / Select lubricant, discharge connecting parts

2. Prepare lube-point

Clean lube-point

Remove grease fi tting

Add reducer, support fl ange 

and tubes (if required)

For remote mounting:

Prefi ll lube-point and any grease lines / connections  

(use the same grease that is contained in the lubrication system)

For direct mounting:

Prefi ll lube-point and any connecting parts 

(use the same grease that is contained in the lubrication system)

3. Activation / Installation of lubrication system

Pressure check: Lube-point / all connecting parts

2022/01 · V

er

si

on: 1.2 · e

n

Select a suitable lubricant 

for perma STAR LC unit

→ e. g. perma Multipurpose grease SF01

Select discharge period

→ e. g. with perma SELECT APP

(refer to our product catalog for details)

Possible mounting positions:

(Oil fi lled LC

+/- 45°)

Assemble drive 

and LC

Tighten threaded ring hand tight until 

the white triangle is completely visible

Note activation / 

exchange date 

on label

Confi guration can be 

found on the back page

Remove plug

Connect the cable to the 

drive by screwing it on

Remove cap and screw 

the lubrication system into 

the lubrication point

Reducer

Remote mounting fo

r lube-points with vibration, 

limited mounting space, high temperature

Direct mounting

Examples: Bearing lubrication

Mounting bracket 

STAR Standard Duty

1-point G1/4 female

(109663)

Hose connector G1/4 male for 

hose iØ 9.5 mm - push-lock

(101554)
Heavy Duty hose up to

+100 °C oØ 16 mm x iØ 9.5 mm 

(101555)

Hose connector G1/4 male for 

hose iØ 9.5 mm - push-lock 

(101554)

Support fl ange STAR

G1/4 male x G1/4 female

(109420)

Support fl ange STAR

Reducer

Add sealant 

(e. g. 

Loctite® 243™)