Perlick HC24BB Скачать руководство пользователя страница 6

6

Operation & Installation Manual

C-Series (HC24 models)

PREPARING THE SPACE

Make sure that the space where the Perlick cabinet(s) is/are to be 
installed is properly prepared. Refer to Figures 1 and 2 (page 5) to 
ensure proper space dimensions and electrical service are correct 
for the model to be installed.

CAUTION

If cabinet is being installed under a countertop it is recommended 

that the countertop be supported by structure other than the 

refrigerated cabinet to prevent damage to the counter top.

IMPORTANT  NOTE:

  For  a  cabinet  door  to  operate  properly,  the 

door must open a minimum of 90°. Use a minimum 3-inch filler 
in  corner  installations  to  assure  a  90°  door  opening.  Allow  24” 
clearance in front of the unit for full door swing, shelf pull-out or 
drawer pull-out. 

IMPORTANT  NOTE:

  Make  sure  the  floor  under  the  unit  is  level 

with  the  surrounding  finished  floor.  Protect  a  finished  floor  with 
plywood, cardboard or some other suitable material before moving 
the unit into place. Failure to do this may result in damage to the 
floor.

PREPARING ELECTRICAL CONNECTIONS

A 115 volt, 60Hz, 15 amp circuit breaker and electrical supply are 
required. A separate circuit is required for each Perlick unit installed.

Follow the National Electrical Code and local codes and ordinances 
when installing the receptacle.

All Perlick units come equipped with a NEMA 5-15P 90° plug with 
a  minimum  of  5-feet  of  cord  extending  beyond  the  rear  of  the 
cabinet. The electrical outlet must be flush with or recessed into 
the back wall.

IMPORTANT  NOTE:

  Never  use  an  extension  cord  to  extend  the 

power cord to the electrical receptacle.

DANGER

ELECTROCUTION HAZARD

Electrical grounding is required. This appliance is equipped with 

a  three  prong  (grounding)  polarized  plug  for  your  protection 

against possible shock hazards.

• 

Never remove the round grounding prong from the plug.

• 

Never use a two-prong grounding adapter.

• 

Never use extension cords to connect power to the unit.

Where  a  two-prong  wall  receptacle  is  encountered  or  a  longer 
power  cord  is  required,  contact  a  qualified  electrician  to  have  it 
replaced in accordance with applicable electrical codes.

DANGER

Failure to comply with the above electrical guidelines may result 

in possible injury, death, fire or loss of property.

UNPACKING AND MOVING

CAUTION

Do  not  cut  cardboard  sleeve  covering  the  unit.  Cutting  may 

result in damage to the exterior of the cabinet. 

1. Uncrate the unit outside on a flat surface. Remove the card-

board sleeve by removing the banding holding the sleeve to 
the shipping base. Carefully lift the cardboard sleeve up over 
the top of the unit. 

2. Carefully lift unit off base and onto a hand truck or dolly (this 

should be done with a minimum of two people; larger units 
may require additional helpers!). Make sure the unit is bal-
anced on transporting device using soft, flexible strapping. 
Protect unit surfaces with cloth material where strapping 
contacts unit. 

3. Before moving unit, secure door to unit with tape to keep the 

door shut. 

4. Carefully move unit to installation site and place in front of 

opening. 

WARNING

A minimum of two people should lift the cabinet off the base to 

prevent possible personal injury.

Содержание HC24BB

Страница 1: ...Luxury Operation Installation Manual C Series HC24 models Form No Z2303 Rev 09 17 2012 HC24RB HC24BB HC24WB...

Страница 2: ......

Страница 3: ...bleshooting section of this manual The information will help you quickly identify a problem and get it remedied In the event you require assistance please contact the dealer where you purchased your u...

Страница 4: ...ean the condenser every three 3 months can cause the unit to malfunction This could void the warranty Never install the unit behind closed doors Be sure front louvered toe plate is free of obstruction...

Страница 5: ...ff floor pull out shelf required for clearance 90 Swing 1 3 16 Min clearance from a corner to acheive 90 door swing 1 16 tolerance 24 with 25 3 8 Values may change due to custom pull with a wood overl...

Страница 6: ...ssed into the back wall IMPORTANT NOTE Never use an extension cord to extend the power cord to the electrical receptacle DANGER ELECTROCUTION HAZARD Electrical grounding is required This appliance is...

Страница 7: ...ti tip brackets and necessary hardware is supplied with the unit The anti tip brackets when properly installed should secure the rear legs and prevent the unit from tipping forward Some installation s...

Страница 8: ...E Leveling legs should not extend more than 3 4 from bottom of the unit 4 Slide cabinet into position Make sure the rear levelling legs slide under the anti tip brackets Push the unit into the open in...

Страница 9: ...storage is available on the lower step for an additional five wine bottles Single Door Beverage Center The single door unit comes with two full extension black vinyl coated wine racks and one Industr...

Страница 10: ...AINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY FORM ELECTRONIC OR MECHANICAL INCLUDING PHOTOCOPYING RECORDING OR USED IN A...

Страница 11: ...ons and are fully interchangable IMPORTANT NOTE Glass with stainless trim and glass with wood trim may sweat in conditions with relative humidity over 75 WOOD OVERLAY INSTALLATION Before beginning ins...

Страница 12: ...12 Operation Installation Manual C Series HC24 models Figure 13 Solid wood overlay panel template...

Страница 13: ...13 Operation Installation Manual C Series HC24 models Figure 14 Glass wood overlay panel template...

Страница 14: ...14 Operation Installation Manual C Series HC24 models Figure 15 Wood overlay drawer panel template...

Страница 15: ...15 Operation Installation Manual C Series HC24 models Figure 16 Lock installation solid wood overlay door panel...

Страница 16: ...16 Operation Installation Manual C Series HC24 models Figure 17 Lock installation wood overlay glass door panel...

Страница 17: ...17 Operation Installation Manual C Series HC24 models Figure 18 Lock installation wood overlay drawer panel...

Страница 18: ...of wood overlay panel with handle fastening locations 2 Drill through wood overlay panel at marked locations taking care not to damage the wood overlay panel 3 Countersink screw heads so screw heads a...

Страница 19: ...ture control OFF Turn the adjusting screw completely counterclockwise to the OFF position until a click is heard The condenser fan and motor turns on and off with the compressor CHECKING PRODUCT TEMPE...

Страница 20: ...remedy before calling for service The problem could be something which can be solved without a service call DANGER NEVER ATTEMPT TO REPAIR OR PERFORM MAINTENANCE ON THE UNIT UNTIL THE MAIN ELECTRICAL...

Страница 21: ...n hot days and in warm room temperatures the system will run longer Problem Condensation forms inside the refrigerated compartments This is normal during high humidity and frequent door openings Are t...

Страница 22: ...United States the District of Columbia or the ten provinces of Canada All service provided by Perlick Corporation under the above warranty must be performed by authorized Perlick service representativ...

Страница 23: ...oever for any incidental consequential or special damages arising from the sale use or installation of the product or from any other causes whatsoever whether based on warranty expressed or implied or...

Отзывы: