PROBLEM
CAUSE
SOLUTION
Refrigerator does not run. No power to the unit.
Check circuit protection devices. Fuses,
breakers, GFI).
Restore power to unit.
Refer to information plate. See
and
Incorrect control settings or faulty control. Return to factory settings (see
) or replace control.
Refrigerator is too warm.
Power
No power to unit.
Restore power to unit.
Refer to information plate. See
and
Incorrectly wired internal wiring
connections.
Verify wiring per wiring diagram. See
Reconnect wires if needed.
Fans
Evaporator fan is not running.
Refer to
Coils
Evaporator coil has iced over.
Remove ice. See
.
Condensing coil is not clean.
Clean with soft brush and vacuum.
Fins are bent or damaged.
Straighten fins.
Control
No power to control.
Refer to
Control is not calling for cooling.
Refer to
Probe failure.
Refer to
Replace probe if needed. See Section
Back Bar Operation Installation Manual
Return to
14
3.0
Troubleshooting Guide – Refrigeration System
Use this diagnostic guide to identify issues and to locate applicable instructions within this service manual.
This diagnostic guide can be used for any of Perlick’s Back Bar Refrigeration Products.
ELECTROCUTION HAZARD!! Never attempt to repair or perform maintenance on the unit
until the Main electrical power has been disconnected.
Unplugging the condensing unit plug from the molded receptacle
shown in the photo IS NOT sufficient to avoid electrical shock
hazard. Disconnect power to the main unit by unplugging the main
power cord from the wall receptacle or disable power to entire
electrical circuit.
Содержание BBR96
Страница 8: ...Back Bar Operation Installation Manual Return to Table of Contents 8...
Страница 65: ...65 Return to Table of Contents Back Bar Operation Installation Manual 9 3 Refrigeration Module DZS Model Series...
Страница 74: ...Back Bar Operation Installation Manual Return to Table of Contents 74 NOTES...
Страница 75: ...75 Return to Table of Contents Back Bar Operation Installation Manual NOTES...
Страница 76: ...8300 West Good Hope Road Milwaukee WI 53223 Toll Free 800 558 5592 Fax 414 353 7069 www perlick com...