Temperature
Probe
Bracket
51
Return to
Back Bar Operation Installation Manual
STEP 1.
STEP 2.
STEP 3.
STEP 4.
STEP 5.
STEP 6.
Figure 7-16. Temperature Probe and Bracket
•
See Table 7-5 for temperature to
resistance values when
troubleshooting probe or tempera-
ture issues.
Table 7-5. Temperature – Resistance Values
7.5.4
Temperature Probe
Each refrigerated zone has one 10K
ohm NTC probe, which senses com-
partment temperature. Sensing probe
is located behind evaporator fan panel.
To replace temperature probe, refer to
section 7.5.3.
7.6 LED Lighting
7.6.1
Replace LED Light Strip
ELECTROCUTION HAZARD!! Never attempt
to repair or perform maintenance on unit
until main electrical power to the unit has
been disconnected!
Open door or remove upper drawer. See Figure
8-13.
Using a flat blade screwdriver, carefully pry off the
lens cover. See Figure 7-4.
Remove two screws securing LED light to housing.
Unplug the LED from the wiring harness.
Plug new LED into harness and secure to housing
using screws removed in step 2.
Snap LED cover into place.
TEMPERATURE
(°C)
TEMPERATURE
(°F)
RESISTANCE
(OHMS)
45
113
4911
50
122
4160
55
131
3536
Tools required
TEMPERATURE
(°C)
TEMPERATURE
(°F)
RESISTANCE
(OHMS)
-30
-22
111300
-25
-13
86430
-20
-4
67770
-15
5
53410
-10
14
42470
-5
23
33900
0
32
27280
5
41
22050
10
50
17960
15
59
14690
20
68
12090
25
77
10000
30
86
8313
35
95
6940
40
104
5827
Содержание BBR96
Страница 8: ...Back Bar Operation Installation Manual Return to Table of Contents 8...
Страница 65: ...65 Return to Table of Contents Back Bar Operation Installation Manual 9 3 Refrigeration Module DZS Model Series...
Страница 74: ...Back Bar Operation Installation Manual Return to Table of Contents 74 NOTES...
Страница 75: ...75 Return to Table of Contents Back Bar Operation Installation Manual NOTES...
Страница 76: ...8300 West Good Hope Road Milwaukee WI 53223 Toll Free 800 558 5592 Fax 414 353 7069 www perlick com...