and reflects this on the TX port of the other SFP by turning off the 
transmitter. When the signal (Link) gets restored and Signal 
Detector becomes active the affected transmitter gets re-enabled.  
 
Standard Mode: In Standard Mode the media converter will 
monitor the fiber link in the same manner. If Signal Detect goes 
down the media converter will output a 25MHz signal on the TX 
port of the other SFP. 

Fiber Fault Alert (Switch 2) 

Switch Position 

Mode 

Up (default) 

Disabled 

Down 

Enabled 

 
Enabled: If the media converter detects a loss of fiber signal on its 
fiber receiver, it will disable its fiber transmitter on the same SFP. 
This, in effect, notifies the fiber link partner that an error condition 
exists on the fiber connection. 
  
Disabled: The Protocol Transparent Media Converter will not 
monitor for Fiber Fault. 

Rate Select (Switch 3) 

Switch Position  Mode 

Up (default) 

High Speed 

Down 

Low Speed 

 
High Speed – When a multi-rated SFP is inserted, it is enabled for 
its higher speed of operation. 
 
Slow Speed – When a multi-rated SFP is inserted, it is enabled 
for its slower speed of operation. 
 

Содержание S-4GPT-DSFP

Страница 1: ...Ver A 1 06 24 2019 Part 5500334 10 Rev B Perle Protocol Transparent Standalone Media Converters Installation Guide S 4GPT DSFP S 4GPT DSFP XT ...

Страница 2: ...n o Multimode to multimode o Multimode to single mode o Single mode to single mode o Multimode to single Mode Single strand o Wavelength Transponder CWDM DWDM o Dual and single fiber Simplex to Duplex Key Features o Protocol and rate transparency for fiber SFPs o Support for all standard MSA complaint SFPs o SFP rates from 1 up to 4 25 Gbps o Support for multi rate SFPs o Smart Link Passthrough o ...

Страница 3: ...es purchased separately into the transceiver ports 3 Connect the power cord strain relief clip optional and connect and apply power DIP Switch Settings The DIP switches are accessible through the opening in the side of the enclosure Link Mode Switch 1 Switch Position Mode Up default Smart Link Pass Through Mode Down Standard Mode Smart Link Pass Through In this mode the fiber link state on one con...

Страница 4: ...osition Mode Up default Disabled Down Enabled Enabled If the media converter detects a loss of fiber signal on its fiber receiver it will disable its fiber transmitter on the same SFP This in effect notifies the fiber link partner that an error condition exists on the fiber connection Disabled The Protocol Transparent Media Converter will not monitor for Fiber Fault Rate Select Switch 3 Switch Pos...

Страница 5: ...5 Attaching the Power Cord Strain Relief Clip For extra power cable strain relief attach the strain clip to the side of the unit then thread the power cable through the clip in either one or two loops ...

Страница 6: ...m 3 16th inch to expose the copper conductor wire 3 Loosen the terminal block screws and connect Positive wire to the left terminal Connect the Negative wire to the right terminal Tighten Terminal screws 0 22Nm 0 25Nm torque 4 Turn on power source 5 Check that the PWR LED light is lit Status LED There are three status LEDs located on the front of the unit PWR On Power is applied to the unit Blinki...

Страница 7: ...g Temperature 0 C 50 C 32 F 122 F 40 C 75 C 40 F 167 F Storage Temperature 25 C 70 C 13 F 158 F 40 C 85 C 40 F 158 F Operating Humidity 5 to 90 non condensing Storage Humidity 5 to 95 non condensing Operating Altitude Up to 3 048 m 10 000 ft Note Please refer the product page on the Perle website for the most up to date models and specifications ...

Страница 8: ... 60950 1 2 nd edition UL 60950 1 CAN CSA STD C22 2 No 60950 1 Warning If this unit is to be installed in a location where the ambient temperature exceeds 50C the case temperature may exceed safe levels For this reason this unit should installed in a restricted access location Warranty Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle produc...

Отзывы: