Perle S-100MM-M2LC2 Скачать руководство пользователя страница 2

Fast Fiber to Fiber Media Converter – Installation Guide

    

Overview 

This document contains instructions necessary for the installation 
and operation of the Perle Fast Fiber to Fiber Standalone Media 
Converters (S-100MM). These products allow dissimilar 100Base-
X fiber interfaces to connect to one another. 

These are the fiber to fiber conversion models: 

 

Multimode to Multimode  (MM) 

 

Multimode to Single Mode ..(SM) 

 

Multimode to Single Mode Single Strand  (SM) 

The first fiber port will be MM and the second fiber port can be 
either single mode (SM) or multimode (MM) depending on the 
model selected. They can operate over different wavelengths and 
distances. (See tables below). 

Fiber port 1 – MM1 

Model  

Connector 

Mode  

Distance  

Wavelength 
(TX/RX)
 

All models

 

SC/ST/LC 

MM.

 

2 km/1.2 mi 

1310 nm 

Fiber port 2 – MM2/SM2 

Model  

Connector 

Mode  

Distance 

Wavelength 
(TX/RX)
 

S-100MM-M2xx2

 

SC/ST/LC 

MM 

 

2 km/1.2 mi.

 

1310 nm 

S-100MM-S2xx20

 

SC/ST/LC 

SM.

 

20 km/12.4 mi.

 

1310 nm 

S-100MM-S2xx40

 

SC/ST/LC 

SM

 

40 km/24.9 mi. 

 

1310 nm 

S-100MM-S2xx80

 

SC/ST/LC 

SM

 

80 km/49.7 mi.

 

1550 nm 

S-100MM-S2xx120 

SC/ST/LC 

SM 

120 km/74.6 mi 

1550 nm 

S-100MM-S1SC20U

 

SC 

SM

 

20 km/12.4 mi.

 

1310/1550 nm

 

S-100MM-S1SC20D

 

SC 

SM

 

20 km/12.4 mi.

 

1550/1310 nm

 

S-100MM-S1SC40U

 

SC 

SM

 

40 km/24.9 mi.

 

1310/1550 nm

 

S-100MM-S1SC40D

 

SC 

SM

 

40 km/24.9 mi.

 

1550/1310 nm  

Note: Please refer to Perle’s web site for the most up to date 
Installation guides, models and specifications: 

http://www.perle.com/

 

Содержание S-100MM-M2LC2

Страница 1: ...P N 5500312 10 Perle Fast Fiber to Fiber Media Converters Installation Guide S 100MM XXXXX...

Страница 2: ...er different wavelengths and distances See tables below Fiber port 1 MM1 Model Connector Mode Distance Wavelength TX RX All models SC ST LC MM 2 km 1 2 mi 1310 nm Fiber port 2 MM2 SM2 Model Connector...

Страница 3: ...Perle Fast Fiber to Fiber media converter 1 Set the DIP switch settings optional 2 Install and connect the fiber cable to port MM1 3 Install and connect the fiber cable to port MM2 SM2 4 Power up the...

Страница 4: ...d down independently of each other A loss of link on either fiber connection can occur without affecting the other fiber connection Far End Fault Switch 2 Switch Position Mode Up default Enabled Down...

Страница 5: ...rd Mode Far End Fault Enabled Media Converter B Configuration Link Mode Link Pass Through Mode Far End Fault Enabled Sequence of Events 1 Media Converter A loses fiber connection RX on MM2 SM2 2 Media...

Страница 6: ...ion on port MM1 is looped back to the transmit TX fiber connection Note Only one fiber interface can be in loopback at a time Remote Loopback Fiber 2 Switch 4 Switch Position Mode Up default Disabled...

Страница 7: ...evice ensuring that the RX and TX are reversed at the opposite end Installing the Simplex Fiber Cable Locate a 100Base X compliant simplex 1 strand fiber cable with appropriate connectors Connect the...

Страница 8: ...er Test On Power is on and in normal operation Blinking slowly the unit is in loopback mode Blinking quickly the unit has a hardware error LK1 MM1 Fiber Link 1 Activity On Fiber link present Blinking...

Страница 9: ...es in the UP position this procedure is recommended for troubleshooting Method 1 1 Set the Link mode to Standard SW1 Down on both media converters Leave all other switches in the Up position 2 Connect...

Страница 10: ...tions Fiber port 1 MM1 Model Mode Wavelength nm TX Power dB RX Power dB Budget dB All models MM TX 1310 RX 1310 Min 20 Max 12 Min 31 Max 14 11 Fiber port 2 MM2 SM2 Model Mode Wavelength nm TX Power dB...

Страница 11: ...Min 0 Max 5 Min 35 Max 3 35 S 100MM S2ST120 SM TX 1550 RX 1550 Min 0 Max 5 Min 35 Max 0 35 S 100MM S2LC120 SM TX 1550 RX 1550 Min 0 Max 5 Min 35 Max 3 35 S 100MM S1SC20U SM TX 1310 RX 1550 Min 14 Max...