Perle Gigabit Fiber to Fiber Media Installation Guide

    

 Troubleshooting

 

General 

 

Ensure power is supplied to the media converter – use of the 
Perle supplied power adapter is highly recommended. 

 

Ensure both devices on either end of the fiber are compatible. 
If using a single fiber connection, ensure that you have both 
an Upstream (U) and Downstream (D) media converter. 

 

Ensure all cabling is of the correct type and is in good 
operating condition. 

 

For dual-stranded fiber connections, ensure the RX and TX 
has been reversed between the 2 media converters.  

No connectivity 

If unable to get full connectivity with all DIP switches in the UP 
position, this procedure is recommended for troubleshooting. 

Method 1 

1.  Turn off Fiber Negotiation (SW1 Down) on both media 

converters. Set Link Mode to Standard. Leave all other 
switches in the UP position. 

2.  Connect the near end device to port MM1, the LK1 LED on 

each media converter should be lit to indicate good fiber 
connections. If the LK1 LED is not lit, then check the fiber 
cable and the attached device. 

3.  Repeat step 2 for port MM2/SM2. 

4.  Return units to desired configuration. 

Method 2 

Each fiber connection can also be verified by configuring the 
remote media converter for loopback mode. The link LEDs 
between the local and remote media converter should be lit. Data 
should pass through the local converter then over the fiber 
connection to the remote media converter. 

Содержание S-1000MM-M2xx05

Страница 1: ...P N 5500314 11 Perle Gigabit Fiber to Fiber Media Converters Installation Guide S 1000MM XXXXXX ...

Страница 2: ... Model Connector Mode Distance Wavelength TX RX All models SC ST LC MM 550 m 1804 ft 850 nm Fiber port 2 MM2 SM2 Model Connector Mode Distance Wavelength TX RX S 1000MM M2xx05 SC ST LC MM 550 m 1804 ft 850 nm S 1000MM M2xx2 SC ST LC MM 2 km 1 2mi 1310 nm S 1000MM S2xx10 SC ST LC SM 10 km 6 2 mi 1310 nm S 1000MM S2xx40 SC ST LC SM 40 km 24 9 mi 1310 nm S 1000MM S2xx70 SC ST LC SM 70 km 43 5 mi 1550...

Страница 3: ...t switch setting all switches in the UP position will work for most installations These are the steps required to configure the Perle Gigabit Fiber to Fiber media converter 1 Set the DIP switch settings optional 2 Install and connect fiber cable to MM1 port 3 Install and connect fiber cable to MM2 SM2 port 4 Power up the media converter DIP Switch Settings The DIP switches are accessible through t...

Страница 4: ...ed Fiber Negotiation should only be turned off if the fiber link partner does not support fiber link negotiations Link Mode Switch 2 Switch Position Mode Up default Smart Link Pass Through Mode Down Standard Mode Smart Link Pass Through In this mode the link state on one connection is directly reflected through the media converter to the other connection If fiber link is lost on one of the connect...

Страница 5: ... Fault Alert FFA Enabled and the local media converter is set up with Smart Link Pass Through a loss of fiber link on either the transmit or receive line will be passed through to the other fiber connection Disabled The media converter will not monitor for fiber fault Note This feature is not required if Fiber negotiation has been enabled since link negotiation accomplishes the same thing When Fib...

Страница 6: ... to this position in order for data to pass through the media converter Enabled This is a test mode All data received on the receive RX fiber connection on port MM1 is looped back to the transmit TX fiber connection Note Only one fiber interface can be in loopback at a time Remote Loopback Fiber 2 Switch 5 Switch Position Mode Up default Disabled Down Enabled Disabled The loopback feature is disab...

Страница 7: ...fiber device ensuring that the RX and TX are reversed at the opposite end Installing the Simplex Fiber Cable 1 Locate a 1000Base X compliant simplex 1 strand fiber cable with male connections 2 Connect the fiber cable from one media converter to the other media converter switch fiber device Powering up the Perle Media Converter 1 Connect the Perle supplied power adapter to the media converter 2 Tu...

Страница 8: ...opback mode Blinking quickly the unit has a hardware error LK1 MM1 Fiber Link Activity On Fiber link present Blinking slowly The fiber link has been taken down as a result of Smart Link Pass Through Blinking quickly Fiber link present and receiving data Off No fiber link present LK2 MM2 SM2 Fiber Link 2 Activity On Fiber link is present Blinking slowly The fiber link has been taken down as a resul...

Страница 9: ...th all DIP switches in the UP position this procedure is recommended for troubleshooting Method 1 1 Turn off Fiber Negotiation SW1 Down on both media converters Set Link Mode to Standard Leave all other switches in the UP position 2 Connect the near end device to port MM1 the LK1 LED on each media converter should be lit to indicate good fiber connections If the LK1 LED is not lit then check the f...

Страница 10: ...cifications Fiber port 1 MM1 Model Mode Wavelength nm TX Power dB RX Power dB Budget dB All models MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 Fiber port 2 MM2 SM2 Model Mode Wavelength nm TX Power dB RX Power dB Budget dB S 1000MM M2xx05 MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 S 1000MM M2xx2 MM TX 1310 RX 1310 Min 6 Max 0 Min 17 Max 0 11 S 1000MM S2xx10 SM TX 1310 RX 1310 Min 9 5 Max ...

Страница 11: ...000MM S1SC80U SM TX 1510 RX 1590 Min 2 Max 3 Min 26 Max 3 24 S 1000MM S1SC80D SM TX 1590 RX 1510 Min 2 Max 3 Min 26 Max 3 24 S 1000MM S1SC120U SM TX 1510 RX 1590 Min 3 Max 2 Min 34 Max 9 31 S 1000MM S1SC120D SM TX 1590 RX 1510 Min 3 Max 2 Min 34 Max 9 31 Fiber Cabling Requirements MM 50 125 microns 62 5 125 microns SM 9 125 microns Note Please refer the product page on the Perle website for the mo...

Страница 12: ...rence in which case the user may be required to take adequate measures EN 55024 Class A Laser Safety IEC 60825 1 2007 This product meets Class I Laser safety requirements per IEC 60825 1 2007 standard and complies with FDA CDRH 21 CFR1040 10 and 21 CFR1040 11 WARNING Visible and invisible laser radiation may be present when cables are not connected Do not stare into the beam or view the beam direc...

Отзывы: