IOLAN SDG1 LA/LE Hardware Installation Guide

Installation

General Cautions and Warnings

Warning

Power sources must be off prior to beginning the power connection steps. 

Read the installation instructions before you connect the unit to its power source.

Warning

Ensure that the voltage and current ratings of the intended power source are 

appropriate for the IOLAN as indicated on the product label.

Warning

Ensure that the installation and electrical wiring of the equipment is performed 

by trained and qualified personnel and that the installation complies with all local and 

national electrical codes. 

Warning

The working voltage inputs are designed for operation with Safety extra low 

Voltage (SELV). Connect only to SELV circuits with voltage restrictions in line with IEC 

62368-1:2018

Warning

: If this equipment is used in a manner not specified by the manufacturer, the 

protection provided by the equipment may be impaired.

Warning

Transient protection shall be provided that is set at a level not exceeding 140% 

of the peak rated voltage value at the supply terminals to the equipment.

Warning

In case of malfunction or damage, no attempts at repair should be made. Do 

not dismantle the product. All repairs need to be made by a qualified Perle 

representative.

Warning

This unit should be installed in a restricted access location where access can 

only be gained by service personnel or users who have been instructed about the reasons 

for the restrictions applied to the location and about any precautions that shall be taken; 

and access is through the use of a tool or lock and key, or any means of security, and is 

controlled by the authority responsible for the location.

Содержание IOLAN SDG1 LA/LE

Страница 1: ...IOLAN SDG1 LA LE Hardware Installation Guide Updated January 2021 Version A3 20 01 2021 Document Part 5500409 10 Rev E www perle com ...

Страница 2: ...ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this hardware guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct th...

Страница 3: ...nstallation 8 Connecting the Hardware 9 Connecting the Serial Port 10 Connecting Data Ports 10 Operation 12 Resetting the IOLAN 12 Resetting the IOLAN to Factory Default Configuration 12 Configuring the IOLAN 12 Appendix A Technical Specifications 13 Appendix B Mechanical Drawing 14 Appendix C Sample Label 15 Appendix D Cabling and Connectors 16 Appendix E IOLAN Maintenance 18 Contacting Perle Sys...

Страница 4: ...IOLAN Secure User s Guide Document Conventions This document contains the following conventions Most text is presented in the typeface used in this paragraph Other typefaces are used to help you identify certain types of information The other typefaces are Note Means reader take note notes contain helpful suggestions Caution Means reader be careful In this situation you might perform an action tha...

Страница 5: ...ardware Installation Guide Overview This guide provides information on installing and doing the initial configuration on the IOLAN SDG1 LA LE unit The IOLAN SDG1 LA LE has one RJ 45 serial port IOLAN SDG1 LA LE Top View ...

Страница 6: ...dix D Cabling and Connectors Button Switch Functions Reset Button The inset Reset button will reboot the IOLAN if pushed in and released quickly It will reset the IOLAN to factory defaults if pushed in and held for more than three seconds For more details on the operation of the Reset button see Resetting the IOLAN Console Serial DIP Switch Serial port 1 can act as a console port or a serial port ...

Страница 7: ...Guide WPS Button Insert a paper clip into the inset hole labeled as WPS and gently press inwards Pressing this button for less than 3 seconds will put the IOLAN SDG1 LA LE in WPS mode greater than 4 seconds will put the unit in Soft AP mode ...

Страница 8: ...ed Error condition State Description Green 1000 Mbps flashes with activity Green Amber 100 Mbps flashes with activity Amber 10 Mbps flashes with activity Off No LAN connection State Description Green solid A cellular connection has been established Green flashing Data is being transmitted over the cellular network Off no cellular connection established State Description Amber Green Wireless signal...

Страница 9: ...G1 LA LE Hardware Installation Guide Port Link Speed State Description Green 1000 Mbps flashes with activity Green Amber 100 Mbps flashes with activity Amber 10 Mbps flashes with activity Off No LAN connection ...

Страница 10: ...h voltage restrictions in line with IEC 62368 1 2018 Warning If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Warning Transient protection shall be provided that is set at a level not exceeding 140 of the peak rated voltage value at the supply terminals to the equipment Warning In case of malfunction or damage no attem...

Страница 11: ...he left screw on the top of the terminal connector block then insert your positive wire into the left terminal and screw it down tight 51Nm torque Loosen the right screw on the top of the terminal connector block then insert your negative wire into the right terminal and screw it down tight 51Nm torque 4 Re insert the terminal block connector if removed Grounding and Power Cord Relief clip If your...

Страница 12: ...nect the cable to one of these ports probably COM1 or COM2 6 Start an terminal emulation program such as Putty or SecureCRT on the COM port where you have connected the IOLAN serial port 7 Configure this COM port within the terminal emulation program with the following parameters 9600 baud 8 data bits 1 stop bit No parity None flow control 8 Connect the power and allow the IOLAN to complete the bo...

Страница 13: ...a fixed speed and duplex settings To connect to 10Base T 100Base TX or 1000Base T follow these steps 1 Connect a straight through Ethernet cable from the IOLAN SDG1 LA LE Ethernet port to an 10 100 1000 RJ45 port on the network hub switch 2 Once the IOLAN SDG1 LA LE is connected and the link is established the link LEDs will turn on These LEDs willindicate whether you have a 10 100 or 1000 Mb s li...

Страница 14: ... be configured operated and monitored using any of the following methods See the IOLAN Secure User s Guide for more details CLI A text based Command Line Interface based on industry standard syntax and structure The CLI can be accessed from the console port An IP address is not required for CLI access on the console port Once an IP address has been assigned the IOAN can also be accessed by Telnet ...

Страница 15: ...tions SDG1 LA LE Power Input Voltage Range 9 30 VDC Typical Power Consumption 24VDC 3 2 Watts Operating Temperature 40 C to 75 C 40 F to 167 F Storage Temperature 40 C to 85 C 40 F to 185 F Operating and Storage Humidity 5 to 95 non condensing Weight 0 4 kg 0 88 lbs Dimensions 110 by 111 by 24 mm 4 3 by 4 4 by 0 9 in ...

Страница 16: ...IOLAN SDG1 LA LE Hardware Installation Guide Appendix B Mechanical Drawing ...

Страница 17: ...IOLAN SDG1 LA LE Hardware Installation Guide Appendix C Sample Label ...

Страница 18: ...ftware config uration If EIA 422 or 485 is selected the line termination may need to be set SW5 has two switches associated with the serial port See Terminating 485 Full Half and 422 Mode below Ensure you have the appropriate cable for connecting your serial devices to the serial ports on the IOLAN IOLAN RJ 45 Connector Pinout Pinout EIA 232 EIA 422 EIA 485 Full Duplex EIA 485 Half Duplex 1 in DCD...

Страница 19: ... for 422 485 half duplex To set TX Termination on port 1 Set DIP switch 2 ON used for 485 full duplex Note For EIA 232 these switches must be in the OFF position default Ethernet Cable The 10 100 1000BaseT X port is located on the back of the IOLAN SDG1 LA LE This Ethernet port will automatically adjust depending on the type of Ethernet cable used straight through or cross over and the type of dev...

Страница 20: ... inches on all sides of the IOLAN SDG1 LA LE to provide proper airflowthrough the unit Do not use solvents or cleaning agents on this unit Keep vent holes clear of debris If case gets dirty wipe with a dry cloth Ensure all cables are in good working condition and replace any frayed cables or cables without clips ...

Страница 21: ...Contact information for the Perle Technical Assistance Center PTAC can be found at the link below https www perle com support_services support_request shtm Warranty Registration This product is covered by the Perle IOLAN SDG Warranty Details can be found at https www perle com support_services warranty shtml ...