background image

IDS-710HP Hardware Installation Guide

PoE Managed Industrial Ethernet Switches

Updated: April 2020

Version: A.07.04.2020

Document Part# 5500455-10

www.perle.com

Содержание IDS-710HP

Страница 1: ...IDS 710HP Hardware Installation Guide PoE Managed Industrial Ethernet Switches Updated April 2020 Version A 07 04 2020 Document Part 5500455 10 www perle com ...

Страница 2: ...ial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this hardware guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense Modifications t...

Страница 3: ...r to the IDS Switch 9 Wiring the Relay Alarm 10 Wiring Digital Input 10 Connecting the Console Port 11 Connecting Data Ports 12 Resetting the Switch 13 Configuring the IDS Switch 16 Appendix A Technical Specifications 17 Appendix B Sample Labels 21 Appendix C Mechanical Drawings 22 Appendix D DIN Rail and Wall Mounting 23 Appendix E IDS Maintenance 25 Appendix F Cables and Connectors 26 ...

Страница 4: ...HP Switch with attached DIN rail mounting bracket IDS 710HP Switches Quick Start Guide Document Conventions This document contains the following conventions Most text is presented in the typeface used in this paragraph Other typefaces are used to help you identify certain types of information The other typefaces are Note Means reader take note notes contain helpful suggestions Caution Means reader...

Страница 5: ...Block Connectors Installation The table below gives a brief overview of the models covered in this guide For more details and for the most up to date list of models please refer to the product pages at www perle com Standard Models 10 100 1000 Base T EthernetPorts PoE Enabled Fixed SFP Port Software Set Temp IDS 710HP 8 2 Pro Standard IDS 710HP XT 8 2 Pro Industrial ...

Страница 6: ...atus LEDs 7 10 100 1000Base T Ethernet Ports with PoE PoE PoE capability 3 Terminal Block for Digital Input and Relay 8 Terminal Block for Power 1 2 4 SFP status LEDs 9 Wall Mount Bracket Screw Holes 5 Console Port MicroUSB 10 DIN Rail Clip State Description Green P1 and P2 power within specifications Yellow solid P1 or P2 providing power within specifications ...

Страница 7: ...rt is the switch s console port When connected the port presents a serial interface that can be used from a PC Terminal emulation program such as PuTTY This provides access to the switch management function using the industry standard CLI command set Red Neither P1 and P2 providing power within specifications State Description State Description Green blinking after power on System booting Green so...

Страница 8: ... trigger an external alarm circuit such as a light or sounding device This connector provides a Normally opened NO dry contact on the connector block Digital Input Connector A Digital Input is provided It can be used for the generation of alarms SNMP trap ener gizing of on board Alarm Relay etc Port Status Indicators Ethernet Port Status Indicators Port Link Speed State Description LED 1 Green LED...

Страница 9: ... Hardware Installation Guide SFP Status LEDs Each SFP has a corresponding LED to indicate the current state of the fiber link State Description Green Fiber link established Green flashing Link activity Off No Link ...

Страница 10: ... Installation Guide Terminal Block Connectors P1 Power Input 1 P2 Power Input 2 Either P1 or P2 can power the unit When both are connected one will act as a backup IN Digital Input Dry Contact Relay Normally Open NO relay ...

Страница 11: ...y responsible for the location Warning The safety of any system incorporating the equipment is the responsibility of the assembler of the system Warning If the unit is installed vertically in a living or office environment the device must be operated exclusively in switch cabinets with fire protection characteristics in accordance with EN 62368 1 Warning The working voltage inputs are designed for...

Страница 12: ...pair copper wires 7 8 mm 3 Loosen the terminal block screws and connect wires into theterminals 4 Tighten terminal screws Ensure the wires are securely fastened 5 Re insert the Terminal block connector if removed 6 Turn on power source See Terminal Block Connectors Warning Ensure power has been removed at the source of the alarm circuit prior to pro ceeding with connections to the alarm relay Warn...

Страница 13: ...IDS Switch 3 On the PC Choose Start Control Panel Systems or equivalent on the Windows Operating System then open the Hardware tab Choose the Device Manager and expand the Ports section The assigned COM port appears can be identified 4 Start an terminal emulation program such as Putty or SecureCRT on the com port where you have connect the cable to the PC 5 Configure your COM port within the emula...

Страница 14: ...net cable toa 10 100 1000 RJ45 connector on the front of the IDS switch Gigabit Ethernet requires CAT 5e orbetter 2 Once the device is connected and link is established the link LEDs will turn on These LEDs willindicate whether you have a 10 100 or 1000 Mb s link to the switch See LED Indicators for moredetails Note It may take a few seconds for the device to become active By default the IDS switc...

Страница 15: ...IDS switch 1 Disconnect the fiber cable from the SFP module 2 If the SFP module is equipped with a clasp move it to the unlocked position and use the clasp to pull the SFP towards you 3 If the SFP module is not equipped with a clasp then with your fore finger and thumb firmly grip the SFP and pull towards you Resetting the Switch The Reset Fast Setup button is located near the bottom of the switch...

Страница 16: ... passwords and security certificates are deleted The start up and backup software are unaffected Follow this procedure Power off the switch Press and hold the reset button While continuing to hold the reset button apply power to the switch ALR LED will go on after power up when it goes out release the reset button The switch is now reset to factory default configuration Booting the Switch When fir...

Страница 17: ...are shipped in Factory default mode Refer to the Quick Start Guide that came with the switch for instructions on how to connect to the switch for the first time Password Recovery When the switch is not in factory default the Fast Setup Mode sequence will activate Password recovery Note The password recovery feature can be disabled in the software LED Behavior PWR Press and hold the Reset FS button...

Страница 18: ...n Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch This interface provides the ability to configure and manage the switch This is accessible through any standard desktop web browser Requires the switch to have a valid IP address Fast Setup This utility provides the ability to do either an ini...

Страница 19: ...0 57 VDC PoE IEEE 803 2bt Type 3 9A Max 54 VDC nominal 50 57 VDC Poe IEEE 802 3at Type 2 5A Max 48 VDC nominal 44 57 VDC PoE 802 3af or IEEE 802 3at type 1 3A Max Alarm Relay NO Normally Open 1 0A 24VDC or 0 3A 48VDC Requires Class 2 LPS or SELV circuit with Fuse protection Digital Input IEC 61131 2 Type 3 Digital Input 24V 2 25 mA Rated Cable Temperatures IDS 710HP IDS 710HP XT 98 C 106 C Overloa...

Страница 20: ...ports 1000Base X and 2500Base X SFP mod ules supplied by Perle Cisco or other manufactur ers of MSA compliant SFPs SFPs supporting SGMII protocol are also supported example 1000Base T Console port MicroUSB Type B female port serial interface Environmental Specifications Operating Temperature Ranges IDS 710HP IDS 710HP XT 10 C to 60 C 14 F to 140 F 40 C to 70 C 40 F to 167 F Storage Temperature Ran...

Страница 21: ...2 EN55032 IEC EN 61000 4 2 ESD Contact discharge 4kV Air Discharge 8kV IEC EN 61000 4 3 RS 80MHz 16Hz 20v m 1 5kHz 2GHz 10v m 2GHz 2 7GHz 5v m IEC EN 61000 4 4 EFT DC power line 2kV Data Line 1kV IEC EN 61000 4 5 Surge DC power line Line Line 1kV Line Earth 2kV Data Line line earth 1kV IEC EN 61000 4 6 CS 150MHz to 80MHz 10Vrms IEC EN 61000 4 8 Magnetic Field 30 A M IEC EN 61000 4 11 IEC EN 61000 ...

Страница 22: ...for the Perle Technical Assistance Center PTAC can be found at the link below www perle com support_services support_request shtml Warranty Registration This product is covered by the Perle Ethernet Switches Warranty Details can be found at https www perle com support_services warranty shtml ...

Страница 23: ...21 IDS 710HP Hardware Installation Guide Appendix B Sample Labels ...

Страница 24: ...22 IDS 710HP Hardware Installation Guide Appendix C Mechanical Drawings ...

Страница 25: ...e DIN rail clip attach onto the top of the DIN rail 3 Rotate the bottom of the IDS switch towards the rail This will snap the bottom hooks of the DIN rail cliponto the bottom of the DIN rail Removing the IDS from the DIN Rail 1 The DIN rail attachment clip has a slot at the bottom of the latch that is visible beneath the switch when it is mounted 2 Insert a flat blade screwdriver into the slot and...

Страница 26: ...spot where the screws will beplaced 4 Drive the screws into the wall leaving about 2 mm of the screw protruding from the wall to allow room for sliding the wall mount panel between the wall and the screws 5 Once the screws are fixed to the wall insert the four screw heads through the large parts of the keyhole shaped screw openings 6 Pull the IDS switch down to lock the IDS switch to the wall moun...

Страница 27: ...2 inches on all sides of the IDS switch to pro vide proper airflowthrough the unit Do not use solvents or cleaning agents on this unit Keep vent holes clear of debris If case gets dirty wipe with a dry cloth Ensure all cables are in good working condition Replace any frayed cables or cables without clips ...

Страница 28: ...tomatically adjust depend ing on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port Requirements Cat 5 UTP or STP Cat 5e cables 24 22 AWG 0 20mm2 0 33mm2 Straight through or Ethernet Crossover cable Note An optional cable adapter is available to provide RJ45 to DB9 conversion Perle s optional RJ45 to DB9 F cross o...

Страница 29: ... watts per port IEEE 802at 2009 Type 2 standards For PoE devices up to 30 watts per port IEEE 802bt Type 3 standards For PoE devices up to 60 watts per port IEEE 802bt Type 4 standards For PoE devices up to 100 watts per port Connect the copper cables from each TP port RJ45 on the IDS 710HP switch to compliant Powered Devices PDs ...

Отзывы: