Installation 15
IDS-509G Hardware Installation Guide
Warning:
Power supply of the equipment must be rated appropriately (see Appendix for specifications)
with limited power. Limited power means complying with one of the following requirements.
Class 2 circuit according to Canadian Electrical Code, Part 1, C22.1
Class 2 circuit according to National Electrical Code, NFPA-70
Limited Power Supply (LPS) according to EN/IEC 60950-1;
Limited-energy circuit according to EN/IEC 61010-1
Warning
: If this equipment is used in a manner not specified by the manufacturer, the protection pro
-
vided by the equipment may be impaired.
Warning:
In case of malfunction or damage, no attempts at repair should be made. Do not dismantle
the product. All repairs need to be made by a qualified Perle representative.
Warning:
Explosion hazard. Do not remove or replace lamps, fuses or plug-in modules (as applicable)
unless power has been disconnected or the area is free of ignitable concentrations.
Warning:
Explosion hazard. Do not disconnect while the circuit is live or unless the area is free of ignit
-
able concentrations.
Terminal Block-Power Connectors
Grounding the IDS switch
If your installation requires additional grounding, follow this procedure.
Grounding the chassis requires the following items:
• One grounding lug (not provided)
• One 12AWG wire (not provided)
Follow the manufacturers instructions for attaching the ground wire to the grounding lug.
Attach the grounding lug to the chassis and secure with the grounding screw provided.
Connecting Power to the IDS Switch
The IDS switch has two power inputs that can be connected simultaneously to provide
redundant power. If one power source fails the other source acts as a backup, and powers
the switch
Wiring with suitable temperature ratings must be used. Refer to specification section for
details.
1. Ensure the power source is off prior to connection
2. Strip both (12-20AWG) wires 7-8 mm(5/16th)
3. Loosen the terminal block screws and connect positive (+) / negative (-) wires into the
+/- terminals
4. Tighten terminal screws (0.5Nm torque). Ensure the wires are securely fastened.
5. Re-insert the Terminal Block connector it removed, Turn on power source. Check
LED indicators in the guide for power status
Содержание IDS-509G
Страница 29: ...Appendix B Sample Labels 27 IDS 509G Hardware Installation Guide Appendix B Sample Labels ...
Страница 30: ...Appendix C Mechanical Drawings 28 IDS 509G Hardware Installation Guide Appendix C Mechanical Drawings ...
Страница 31: ...Appendix C Mechanical Drawings 29 IDS 509G Hardware Installation Guide ...
Страница 32: ...Appendix C Mechanical Drawings 30 IDS 509G Hardware Installation Guide ...