Appendix A - Technical Specifications 24
IDS-509F Hardware Installation Guide
Appendix A - Technical Specifications
Technical Specifications
Power
Power Connector
• 4-Pin Removable Terminal Block
• Grounding screw on metal chassis
• Dual Power Input
Input Voltage
• 12/24/48 VDC Nominal(9.6 to 60 VDC) - 2.0A Max
• 24 VAC Nominal (18-30 VAC) - 1.6A Max
Alarm Relay
• NO (Normally Open), NC (Normally Closed con
-
tacts
• 1.0A @ 24VDC or 0.5A @ 48VDC
• Requires Class 2/LPS or SELV circuit with Fuse pro
-
tection
Digital Input: IN1
• Connects to Dry Contact Circuit
• Provides: 12V, 36mA
• On: > 2.1mA (< 4K Ohms)
• Off: < 1.2mA (>9K Ohms)
Digital Input: IN2
• Connect to Wet Contact Circuit (requires external
power)
• Input Voltage Rating: -36 to +36 VDC
• Input Impedance: 4K Ohms
• On: >10VDC
• Off: <5VDC
Rated Cable Temperatures
IDS-509F
IDS-509F-XT
>74° C
>113° C
Overload Current Protection
Fuse
Reverse polarity protection
Yes
Interfaces
10/100/1000Base-T (RJ45)
• Up to 100 meters (328 ft.)
• Auto-negotiation
• Auto-MDI/MDIX
• Ethernet isolation 1500 V
100Base-X Fiber Ports
• 100Base-X in a variety of wavelengths, distances
and connectors
Console port
• RJ45 DTE - serial port
• MicroUSB Type B female port - serial interface
Switch properties
Содержание IDS-509F
Страница 29: ...Appendix B Sample Labels 27 IDS 509F Hardware Installation Guide Appendix B Sample Labels ...
Страница 30: ...Appendix C Mechanical Drawings 28 IDS 509F Hardware Installation Guide Appendix C Mechanical Drawings ...
Страница 31: ...Appendix C Mechanical Drawings 29 IDS 509F Hardware Installation Guide ...
Страница 32: ...Appendix C Mechanical Drawings 30 IDS 509F Hardware Installation Guide ...