Installation                                                                                                       20

IDS-509F Hardware Installation Guide

Connecting Data Ports

Ethernet Connections

By default all of the 10/100/1000 ports will automatically set themselves up to match the 

speeds of all attached devices. If auto negotiation is not supported by one or more attached 

devices, the ports can be configured to operate at fixed speeds and duplex settings.

Warnin

g: 

In hazardous location installations, failure to remove the power from the source 

prior when completing the wiring connections to the Ethernet ports could cause an electri

-

cal arc resulting in a possible explosion.

To connect to 10Base-T, 100Base-TX or 1000Base-T follow these steps:

1. When connecting to devices, workstations, servers or routers connect a straight 

through Ethernet cable to a 10/100/1000 RJ45 connector on the front of the IDS 

switch. Gigabit Ethernet requires CAT5 or better.

2. Once the device is connected and link is established the link LEDs will turn on. These 

LEDs will indicate whether you have a 10,100 or 1000 Mb/s link to the switch. See. 

(LED Indicators) for more details.

Note: 

It may take a few seconds for the device to become active. By default the IDS 

switch will have Rapid Spanning Tree (RSTP) protocol enabled. This protocol will first 

check the network for any cabling loops prior to bringing the port up, in order to prevent 

network disruptions.

Fiber Connections

To connect to 100Base-X follow these steps:

1. Connect 100Base-X devices to the fiber ports using appropriate fiber cables. Ensure 

that cable implements the proper the TX to RX crossover

2. Once the device is connected and link is established the link LEDs will turn on.The 

LED will begin to flash once data activity is initiated. See. (LED Indicators) for more 

details.

Note: 

It may take a few seconds for the device to become active. By default the IDS 

switch will have Rapid Spanning Tree (RSTP) protocol enabled. This protocol will first 

check the network for any cabling loops prior to bringing the port up, in order to prevent 

network disruptions.

Содержание IDS-509F

Страница 1: ...IDS 509F Hardware Installation Guide Managed Industrial Ethernet Switches Updated October 2019 Version A 2 01 10 2019 Document Part 5500383 10 www perle com ...

Страница 2: ...ence when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this hardware guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the i...

Страница 3: ...Grounding the IDS switch 15 Connecting Power to the IDS Switch 15 Wiring the Relay Alarm 16 Wiring Digital Inputs 17 Connecting the Console Port 18 Connecting Data Ports 20 Resetting the Switch 21 Configuring the IDS Switch 23 Appendix A Technical Specifications 24 Appendix B Sample Labels 27 Appendix C Mechanical Drawings 28 Appendix D DIN Rail and Wall Mounting 31 Appendix E IDS Maintenance 33 A...

Страница 4: ...itch with attached DIN rail mounting bracket Quick Start Guide Document Conventions This document contains the following conventions Most text is presented in the typeface used in this paragraph Other typefaces are used to help you identify certain types of information The other typefaces are Note Means reader take note notes contain helpful suggestions Caution Means reader be careful In this situ...

Страница 5: ...more details and for the most up to date list of models please refer to the product pages at www perle com XXXXXXX represents fiber ports of different wavelengths distances and connectors Standard Models 10 100 1000Base T Ports Fiber Ports Temp IDS 509F XXXXXXX 8 1 Standard IDS 509F2 XXXXXXX 7 2 Standard IDS 509F3 XXXXXXX 6 3 Standard IDS 509F XXXXXXX XT 8 1 Industrial IDS 509F2 XXXXXXX XT 7 2 Ind...

Страница 6: ...xxxxxx XT 1 Terminal Block for Power 1 2 8 Terminal Block Relay I O 2 Status LEDs 9 Fiber Status LED 3 Console Port serial 10 100Base X Fiber port 4 Console Port USB 11 Reset FS Fast Setup 5 DIP switches 12 Wall Mount Bracket Screw Holes 6 10 100 10100 Base T Ports 13 DIN Rail Clip 7 SD Card Slot ...

Страница 7: ... for Power 1 2 8 SD Card Slot 2 Status LEDs 9 Terminal Block Relay I O 3 Console Port serial 10 10 100 1000 Base T Port 4 Console Port USB 11 100Base X Fiber Ports 5 DIP switches 12 Reset FS Fast Setup 6 Fiber Port Status LEDs 13 Wall Mount Bracket Screw Holes 7 10 100 1000 Base T Ports 14 DIN Rail Clip ...

Страница 8: ...ck for Power 1 2 8 SD Card Slot 2 Status LEDs 9 Terminal Block Relay I O 3 Console Port serial 10 Fiber Port Status LED 4 Console Port USB 11 100Base X Fiber Port 5 DIP switches 12 Reset FS Fast Setup 6 Fiber Port Status LEDs 13 Wall Mount Bracket Screw Holes 7 10 100 1000 Base T Ports 14 DIN Rail Clip ...

Страница 9: ...nking after power on System booting Green solid System ready operating normally Green blinking slowly Fast Setup Mode activated port available Green blinking fast Fast Setup Mode activated no port avail able Red Hardware fault or firmware load error State Description Off No alarms configured Green solid Alarms configured but no alarms detected Red solid Alarm condition detected Red blinking Alarm ...

Страница 10: ...ing Master not activated Green solid Ring Master Active redundant port blocked Coupling Link enabled Green flashing Ring Master unable to establish a ring due to missing link on one of the Ring ports Yellow solid Ring Master Active redundant port unblocked indi cates a break in the Ring ...

Страница 11: ...B Console Port The MicroUSB port is an alternative connection to the switch s console This provides access to the switch management function using the industry standard CLI command set When connected the port presents a serial interface that can be used from a PC Terminal emulation program such as PuTTY Power Connector The power input connector has provisions for dual inputs Two independent power ...

Страница 12: ...eed Green andYellow LEDs Fiber Port Status Indicators Port Link State Description Green 1000 Mbps Green Yellow 100 Mbps Yellow 10 Mbps On solid Port Link Random blinking Port Link and Activity Slow blinking Error disabled Rapid blinking Port in Fast Setup Mode State Description Green Link Green Flashing Link Activity ...

Страница 13: ...Hardware Installation Guide Terminal Block Connectors P1 Power Input 1 P2 Power Input 2 IN 1 Digital Input 1 Dry Contact IN 2 Digital Input 2 Wet Contact R Relay with 2 connection points Normally Open NO Normally Closed NC ...

Страница 14: ...ional parameters as well as the more advanced Ring features DIP Switch Ring Feature SW1 SW2 Ring Role Coupling Mode Description On On Software control Ring Master functionality is controlled by software configuration On Off Master Primary Ring Feature enabled Ring Role Master Coupling Active on Port 4 Note 1 Off On Client Standby Ring feature enabled Ring Role Client Coupling Backup on Port 4 Note...

Страница 15: ... Hardware Installation Guide Port Assignment Note DIP switches are read during system boot up If a DIP switch is changed the IDS switch must be rebooted in order for the change to take effect Ring Ports 1 2 Coupling Port 4 ...

Страница 16: ...protection characteristics in accordance with EN 60950 1 Warning The working voltage inputs are designed for operation with Safety extra low Voltage SELV Connect only to SELV circuits with voltage restrictions in line with IEC EN 60950 1 Hazardous Location Warnings Warning This equipment shall be installed in an enclosure that provides a degree of protection not less then IP54 in accordance with E...

Страница 17: ...ect while the circuit is live or unless the area is free of ignit able concentrations Terminal Block Power Connectors Grounding the IDS switch If your installation requires additional grounding follow this procedure Grounding the chassis requires the following items One grounding lug not provided One 12AWG wire not provided Follow the manufacturers instructions for attaching the ground wire to the...

Страница 18: ...ce is off prior to connection 2 Strip 2x12 20AWG 3 31 mm 0 52 mm twisted pair copper wires 7 8 mm 3 Loosen the terminal block screws and connect wires into theterminals 4 Tighten terminal screws Ensure the wires are securely fastened 5 Re insert the Terminal block connector if removed 6 Turn on power source Warning Ensure power has been removed at the source of the alarm circuit prior to pro ceedi...

Страница 19: ...2 mm twisted pair copper wires 7 8 mm 3 Loosen the terminal block screws and connect wires into theterminals For IN2 ensure that the live side of the input circuit is connected to the terminal and the return to the 4 Tighten terminal screws Ensure the wires are securely fastened 5 Re insert the Terminal block connector if removed 6 Turn on power source Warning Ensure power has been removed at the ...

Страница 20: ...ager Expand the Ports COM LPT section This will expand the drop down to show the number of com ports on your sys tem Connect the cable to one of these ports probably com1 or com2 4 Start an terminal emulation program such as Putty or SecureCRT on the COM port where you have connected the cable PC 5 Configure this COM port within the terminal emulation program with the following parameters 9600 bau...

Страница 21: ...rs can be identified 4 Start an terminal emulation program such as Putty or SecureCRT on the com port where you have connect the cable to the PC 5 Configure your COM port within the emulation program on the PC as 9600 baud 8 data bits 1 stop bit No parity None flow control 6 The PC will display the bootloader sequence 7 Press Enter to display the setup prompt when the booting of the IDS is complet...

Страница 22: ...k is established the link LEDs will turn on These LEDs willindicate whether you have a 10 100 or 1000 Mb s link to the switch See LED Indicators for moredetails Note It may take a few seconds for the device to become active By default the IDS switch will have Rapid Spanning Tree RSTP protocol enabled This protocol will first check the network for any cabling loops prior to bringing the port up in ...

Страница 23: ...again or by disconnecting power at source and re applying Press and hold the reset button for at least 8 seconds The switch will perform a complete power down and stay in the powered off state Press the reset button again to power the switch on Reset to Factory Default Configuration The switch can be reset to the Factory default configuration When this is done all config uration user IDs passwords...

Страница 24: ...mode the switch assigns itself an IP address and also assigns an IP address to the connected PC This makes it possible to initiate a Web session and the use of the Fast Setup configurator Switches are shipped in Factory default mode Refer to the Quick Start Guide that came with the switch for instructions on how to connect to the switch for the first time Password Recovery When the switch is not i...

Страница 25: ... Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch This interface provides the ability to configure and manage the switch This is accessible through any standard desktop web browser Requires the switch to have a valid IP address Fast Setup This utility provides the ability to do either an initial ...

Страница 26: ...on Digital Input IN1 Connects to Dry Contact Circuit Provides 12V 36mA On 2 1mA 4K Ohms Off 1 2mA 9K Ohms Digital Input IN2 Connect to Wet Contact Circuit requires external power Input Voltage Rating 36 to 36 VDC Input Impedance 4K Ohms On 10VDC Off 5VDC Rated Cable Temperatures IDS 509F IDS 509F XT 74 C 113 C Overload Current Protection Fuse Reverse polarity protection Yes Interfaces 10 100 1000B...

Страница 27: ...0 non condensing Operating Altitude Up to 3 048 meters 10 000 feet Standards and Certifications Safety UL 60950 1 IEC 60950 1 2005 A1 2009 and EN 60950 1 2006 A11 2009 A1 2010 A12 2011 CE Mark Industrial Safety UL 61010 1 and UL 61010 2 201 Formerly UL508 Emissions FCC 47 Part 15 Class A CISPR 22 2008 EN55022 2010 Class A CISPR 24 2010 EN 55024 2010 EMC and Immunity CISPR 24 2010 EN 55024 2010 IEC...

Страница 28: ...tact information for the Perle Technical Assistance Center PTAC can be found at the link below www perle com support_services support_request shtml Warranty Registration This product is covered by the Perle Ethernet Switches Warranty Details can be found at https www perle com support_services warranty shtml ...

Страница 29: ...Appendix B Sample Labels 27 IDS 509F Hardware Installation Guide Appendix B Sample Labels ...

Страница 30: ...Appendix C Mechanical Drawings 28 IDS 509F Hardware Installation Guide Appendix C Mechanical Drawings ...

Страница 31: ...Appendix C Mechanical Drawings 29 IDS 509F Hardware Installation Guide ...

Страница 32: ...Appendix C Mechanical Drawings 30 IDS 509F Hardware Installation Guide ...

Страница 33: ...oks of the DIN rail clip attach onto the top of the DIN rail 3 Rotate the bottom of the IDS switch towards the rail This will snap the bottom hooks of the DIN rail cliponto the bottom of the DIN rail See diagram below Removing the IDS from the DIN Rail 1 The DIN rail attachment clip has a slot at the bottom of the latch that is visible beneath the switch when it is mounted 2 Insert a flat blade sc...

Страница 34: ... guide to mark the spot where the screws will beplaced 4 Drive the screws into the wall leaving about 2 mm of the screw protruding from the wall to allow room for sliding the wall mount panel between the wall and the screws 5 Once the screws are fixed to the wall insert the four screw heads through the large parts of the keyhole shaped screw openings 6 Pull the IDS switch down to lock the IDS swit...

Страница 35: ...ce of 50 8mm 2 inches on all sides of the IDS switch to pro vide proper airflowthrough the unit Do not use solvents or cleaning agents on this unit Keep vent holes clear of debris If case gets dirty wipe with a dry cloth Ensure all cables are in good working condition Replace any frayed cables or cables without clips ...

Страница 36: ...E pinouts Ethernet Cables The 10 100 1000BaseT X ports located on the IDS switch s front panel are used to con nect to Ethernet enabled devices These Ethernet ports will automatically adjust depend ing on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port Requirements Cat 5 UTP or STP Cat 5e cables 24 22 AWG 0 20m...

Страница 37: ...DB0020C enables a straight through Ethernet cable to connect the RJ45 console port to a PC serial port Fiber Cables Duplex SC or ST connector Multimode 50 125 or 62 5 125 micron fiber cable Single mode 9 125 micron fiber cable Simplex BIDI single strand SC or ST connector Multimode 50 125 or 62 5 125 micron fiber cable Single mode 9 125 micron fiber cable Ethnernet Connector 8 pin RJ 45 Fiber Conn...

Отзывы: