background image

Fast Ethernet Fiber to Fiber Media Module – Installation Guide

    

12 

Technical Specifications 

The following applies to all C-100MM and CM-100MM media 
converter modules: 

Power Input/Consumption 

12V DC /3.5 W 

Operating Temperature: 

0°C to 50°C (32°F to 122°F)

 

Storage Temperature:   

-

25°C to 70°C (-13°F to 158°F) 

Operating Humidity:   

5% to 90% non-condensing

 

Storage Humidity: 

 

5% to 95% non-condensing

 

Operating Altitude: 

 

Up to 3,048 m (10,000 ft) 

Weight: 

 

 

0.15 kg (0.33 lbs) 

MTBF: (C-100MM) 

 

484,202 hours 

            (CM-100MM) 

 

489,076 hours 

Dimensions: 

 

 

203 mm by 38 mm by 152 mm 

 

 

 

 

(8 in. By 1.5 in by 6 in 

Fiber Optic Specifications 

Fiber port 1 – MM1 

Model 

Mode 

Wave 

length 

(nm) 

TX Power 

(dB) 

RX Power 

(dB) 

Budget 
   (dB) 

C-100MM-M2SC2 
CM-100MM-M2SC2 

MM 

TX: 1310 
RX: 1310 

Min:   -20 
Max:  -12 

Min:   -31 
Max:  -14 

11 

Fiber port 2 – MM2/SM2 

Model 

Mode 

Wave 

length 

(nm) 

TX Power 

(dB) 

RX Power 

(dB) 

Budget 
   (dB) 

C-100MM-M2SC2 
CM-100MM-M2SC2 

MM 

TX: 1310 
RX: 1310 

Min:   -20 
Max:  -12 

Min:   -31 
Max:  -14 

11 

C-100MM-M2ST2 
CM-100MM-M2ST2 

MM 

TX: 1310  
RX: 1310 

Min:   -20 
Max:  -12 

Min:   -31 
Max:  -14 

11 

C-100MM-M2LC2 
CM-100MM-M2LC2 

MM 

TX: 1310 
RX: 1310 

Min:   -20 
Max:  -12 

Min:   -30 
Max:  -14 

10 

C-100MM-S2SC20 
CM-100MM-S2SC20 

SM 

TX: 1310 
RX: 1310 

Min:   -18 
Max:  -7 

Min:   -32 
Max:  -3 

14 

C-100MM-S2ST20 
CM-100MM-S2ST20 

SM 

TX: 1310 
RX: 1310 

Min:   -15 
Max:  -8 

Min:   -32 
Max:  -3 

17 

Содержание CM-100MM Series

Страница 1: ...P N 5500313 10 Perle Fast Ethernet Fiber to Fiber Media Converter Module Installation Guide C 100MM XXXXX Unmanaged Module CM 100MM XXXXX Managed Module...

Страница 2: ...d SM These media converter modules operate over different wavelengths and distances depending on the model selected See tables below For information on the management options of the CM 100MM converter...

Страница 3: ...D SC SM 20 km 12 4 mi 1550 1310 nm C 100MM S1SC40U CM 100MM S1SC40U SC SM 40 km 24 9 mi 1550 1310 nm C 100MM S1SC40D CM 100MM S1SC40D SC SM 40 km 24 9 mi 1550 1310 nm Note Please refer to Perle s web...

Страница 4: ...5 Refer to the diagram below for labelling This jumper only applies to the CM 100MM converter module Auto Pin 2 and Pin 3 are strapped When set to Auto At power up the media module will check its inte...

Страница 5: ...Position Mode Up default Link Pass Through Mode Down Standard Mode Link Pass Through In this mode the link state on one fiber connection is directly reflected through the media module to the other fib...

Страница 6: ...iber link to the remote end module This in effect notifies the fiber link partner that an error condition exists on the fiber connection Note This switch needs to be set to either generate or detect t...

Страница 7: ...must be set to this position in order for data to pass through the media module Enabled This is a test mode All data received on the receive RX fiber connection is looped back to the transmit TX fiber...

Страница 8: ...veal the slot opening Set the jumpers and DIP switches on the media module to the desired operating mode optional Locate the top and bottom alignment guides inside the MCR chassis Using the module ali...

Страница 9: ...ew Installing the Duplex Fiber Cable Locate a 100Base X compliant duplex 2 strands fiber cable with the appropriate connectors Connect the fiber cables from the media module to the other media module...

Страница 10: ...Test On Power is on the module is operating normally Blinking slowly the module is in loopback mode Blinking quickly the module has a hardware error LK1 MM1 Fiber Link 1 Activity On Fiber link presen...

Страница 11: ...ng Note If troubleshooting a CM 100 setting the Auto Config jumper J5 to SW will ensure the DIP switches are being read Method 1 1 Set the Link mode to Standard SW1 Down on both media converter module...

Страница 12: ...03 mm by 38 mm by 152 mm 8 in By 1 5 in by 6 in Fiber Optic Specifications Fiber port 1 MM1 Model Mode Wave length nm TX Power dB RX Power dB Budget dB C 100MM M2SC2 CM 100MM M2SC2 MM TX 1310 RX 1310...

Страница 13: ...M S2LC80 SM TX 1550 RX 1550 Min 5 Max 0 Min 34 Max 3 29 C 100MM S2SC120 CM 100MM S2SC120 SM TX 1550 RX 1550 Min 0 Max 5 Min 35 Max 3 35 C 100MM S2ST120 CM 100MM S2ST120 SM TX 1550 RX 1550 Min 0 Max 5...

Страница 14: ...n which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio inte...

Страница 15: ...d at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Suppo...