background image

P/N 5500308-13 

 

 

        Perle 10/100/1000 Ethernet  

    Media Converter 

Module 

 

 

Installation Guide 

 

Unmanaged

 

 

Managed 

 

C-1110-M2SC05 

CM-1110-M2SC05  

C-1110-M2LC05 

CM-1110-M2LC05 

C-1110-S2LC10 

CM-1110-S2LC10 

C-1110-S2SC10 

CM-1110-S2SC10 

C-1110-S2LC40 

CM-1110-S2LC40 

C-1110-S2SC70 

CM-1110-S2SC70 

C-1110-S2LC70 

CM-1110-S2LC70 

C-1110-S1SC10U 

CM-1110-S1SC10U 

C-1110-S1SC10D 

CM-1110-S1SC10D 

C-1110-SFP 

 

CM-1110-SFP 

 

 

 

 

 

 

 

 

Содержание C-1110-M2LC05

Страница 1: ...anaged C 1110 M2SC05 CM 1110 M2SC05 C 1110 M2LC05 CM 1110 M2LC05 C 1110 S2LC10 CM 1110 S2LC10 C 1110 S2SC10 CM 1110 S2SC10 C 1110 S2LC40 CM 1110 S2LC40 C 1110 S2SC70 CM 1110 S2SC70 C 1110 S2LC70 CM 11...

Страница 2: ...nagement options of the CM 1110 module refer to the MCR MGT Module User s Guide Model Connector Mode Distance Wavelength C 1110 M2SC05 CM 1110 M2SC05 SC MM 550 m 1804 ft 850 nm C 1110 M2LC05 CM 1110 M...

Страница 3: ...ional 5 Insert the Media Converter Module into the chassis 6 Connect the copper cable 7 Connect the fiber cable Auto MDIX Jumper Note The factory settings for Auto MDIX will work for most installation...

Страница 4: ...uto When set to Auto the module will at power up check its internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this as its ru...

Страница 5: ...erter Module will negotiate with its link partner to determine the most optimal parameters for this connection The C 1110 and CM 1110 will advertise capabilities of 10 100 and 1000 Mbps full and half...

Страница 6: ...on both ends of the fiber link and both setup for Link Pass Through a loss of copper link on the far end device will propagate through both Converters and will result in a loss of copper link at the n...

Страница 7: ...ink to be brought down Note This feature only takes effect if Fiber Negotiation has been turned off Disabled The Media Converter Module will not monitor for or generate Fiber Fault Alert The following...

Страница 8: ...connection Up The Media Converter Module will be set to Full Duplex mode Down The Media Converter Module will be set to Half Duplex mode Speed copper Switch 5 Switch Position Mode Up default 100 Down...

Страница 9: ...e 1000Mbps Full and Half Duplex no Pause Down The Media Converter Module s fiber will be fixed to 1000Mbps Full Duplex Loopback Switch 7 Switch Position Mode Up default Disabled Down Enabled Disabled...

Страница 10: ...ng a cross head screwdriver remove the screw holding the face plate to the Chassis to reveal the slot opening 3 Set the jumpers and DIP switches on the Media Converter Module to the desired operating...

Страница 11: ...e and gently pull the Media Converter Module out 2 If not inserting a replacement cover the opening slot with a face plate and secure the screw Installing the SFP Fiber Module C 1110 SFP and CM 1110 S...

Страница 12: ...Fiber Cable Locate a 1000Base X compliant simplex 1 strand fiber cable with appropriate connectors Connect the fiber cable from the Media Converter Module to the other Media Converter switch fiber dev...

Страница 13: ...DF fiber On Full Duplex Mode Off Half Duplex Mode LKF fiber On Fiber link is present Off No fiber link present Blinking slow Copper link down but fiber link appears functional Blinking fast Fiber link...

Страница 14: ...re the Media Converter Module brings down a link to convey status there is potential for a deadlock Recovery is achieved by momentarily restoring the link to see if the original failure has been resol...

Страница 15: ...full connectivity with all DIP switches in the UP position these methods are recommended for troubleshooting Method 1 1 If the Module is a CM 1110 set the Auto Config jumper J6 to SW so that DIP swit...

Страница 16: ...onverter for loopback mode The LKF LEDs on both Media Converters Modules should be lit Data should pass through the local converter over the fiber connection to the remote Media Converter At the remot...

Страница 17: ...er dB RX Power dB Budget dB C 1110 M2SC05 CM 1110 M2SC05 MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 C 1110 M2LC05 CM 1110 M2LC05 MM TX 850 RX 850 Min 9 5 Max 4 Min 17 Max 3 7 5 C 1110 M2LC10 CM 1...

Страница 18: ...50 125 microns or 62 5 125 microns SM 9 125 microns Ethernet Copper Cabling Requirements Category 5 UTP or STP 24 22 AWG Straight through or Ethernet crossover Note Please refer the product page on th...

Страница 19: ...n which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio inte...

Страница 20: ...at http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Suppor...

Отзывы: