Perle 10/100 Media Converter Module – Installation Guide

  

 

Converter Module will be determined by the Duplex (switch 4) and 
Speed (switch 5) dip switch settings. 

 

Link Mode (Switch 2) 
 

Switch Position  Mode 

Up (default) 

Link Pass-Through Mode 

Down 

Standard Mode 

 
Link Pass-Through: In this mode, the link state on one connection is 
directly reflected through the Media Converter Module to the other 
connection. If the link is lost on one of the connections, then the other 
link will be brought down. 
 
With Media Converters on both ends of the fiber link and both setup 
for Link Pass-Through, a loss of copper link on the far end device will 
propagate through both Converters and will result in a loss of copper 
link at the near end device. This would, in effect, resemble a direct 
copper connection 
 
Standard Mode: In this mode, the links on the fiber and copper sides 
can be brought up and down independently of each other. A loss of 
link on either the fiber or copper port can occur without affecting the 
other connection. 
 
 

Far End Fault (Switch 3) 
 

Switch Position  Mode 

Up (default) 

Enabled 

Down 

Disabled 

 
Enabled: If the Media Converter Module detects a loss of receive 
fiber signal, it will transmit a FEF signal to the remote Media 
Converter. This, in effect, notifies the fiber link partner that an error 
condition exists on the fiber connection. 
 
If the remote Media Converter is set up for Far End Fault (FEF) and 
the local Media Converter is set up with Link Pass-Through, a loss of 

Содержание C-110-M2ST2

Страница 1: ...P N 5500307 15 Perle 10 100 Ethernet Media Converter Module Installation Guide C 110 XXXXX Unmanaged Module CM 110 XXXXX Managed Module...

Страница 2: ...formation on management features of the CM 110 module refer to the MCR MGT Module User s Guide Model Connector Mode Distance Wavelength C 110 M2ST2 CM 110 M2ST2 SC ST LC MM 2 km 1 2 mi 1310 nm C 110 S...

Страница 3: ...a Converter Module into the Chassis 5 Connect the fiber cable 6 Connect the copper cable Auto MDIX Jumper Note The factory settings for Auto MDIX will work for most installations but if there is a nee...

Страница 4: ...When set to Auto the module will at power up check its internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this as its runni...

Страница 5: ...operation the Media Converter Module will negotiate Ethernet parameters on the copper connection This will ensure that the most optimal connection parameters will be used If the copper link partner d...

Страница 6: ...agate through both Converters and will result in a loss of copper link at the near end device This would in effect resemble a direct copper connection Standard Mode In this mode the links on the fiber...

Страница 7: ...or detect the FEF signal then the FEF switch needs to be set Disabled The Media Converter Module will not monitor for or generate Far End Fault The following diagram is an illustration of the operati...

Страница 8: ...connection Up The Media Converter Module will be set to Full Duplex mode Down The Media Converter Module will be set to Half Duplex mode Speed copper Switch 5 Switch Position Mode Up default 100 Down...

Страница 9: ...h 7 Switch Position Mode Up default Disabled Down Enabled Disabled This is the setting for normal operation The switch must be set to this position in order for data to pass through the Media Converte...

Страница 10: ...ia Converter Module from its packaging 2 Using a cross head screwdriver remove the screw holding the face plate to the Chassis to reveal the slot opening 3 Set the jumpers and DIP switches on the Medi...

Страница 11: ...ntly pull the Media Converter Module out 2 If not inserting a replacement cover the opened slot with a face plate and secure the screw Installing the Duplex Fiber Cable Locate a 100Base X compliant du...

Страница 12: ...nstalling the Copper Cable Locate 10 100Base T compliant copper cables with male RJ 45 connectors installed at both ends Connect the RJ 45 cable between the Perle Media Converter Module and the device...

Страница 13: ...dule is in Loopback mode Blinking fast The module has a hardware failure FDF fiber On Full Duplex Mode Off Half Duplex Mode LKF fiber On The fiber link is present Off No fiber link is present Blinking...

Страница 14: ...e Media Converter Module brings down a link to convey status there is potential for a deadlock Recovery is achieved by momentarily restoring the link to see if the original failure has been resolved I...

Страница 15: ...If unable to get full connectivity with all DIP switches in the UP position these methods are recommended for troubleshooting Method 1 1 If the Module is a CM 110 set the Auto Config jumper J6 to SW s...

Страница 16: ...Converters should be lit Data should pass through the local converter over the fiber connection to the remote Media Converter At the remote Media Converter the data will be looped back and passed thro...

Страница 17: ...1 C 110 M2LC2 CM 110 M2LC2 MM TX 1310 RX 1310 Min 20 Max 12 Min 30 Max 14 10 C 110 S2SC20 CM 110 S2SC20 SM TX 1310 RX 1310 Min 18 Max 7 Min 32 Max 3 14 C 110 S2ST20 CM 110 S2ST20 SM TX 1310 RX 1310 Mi...

Страница 18: ...TX 1550 RX 1310 Min 14 Max 8 Min 32 Max 3 18 C 110 S1SC40U CM 110 S1SC40U SM TX 1310 RX 1550 Min 8 Max 3 Min 33 Max 3 25 C 110 S1SC40D CM 110 S1SC40D SM TX 1550 RX 1310 Min 8 Max 3 Min 33 Max 3 25 Fib...

Страница 19: ...hich case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interfe...

Страница 20: ...t http www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support...

Отзывы: