Fast Ethernet Media Converter – Installation Guide

    

 

 
Auto-Config Jumper (CM-100 only) 

The Auto-Config jumper (J6) is located just below the Auto-MDIX 
jumper (see above). Refer to the diagram below for labelling. 
This jumper only applies to CM-100 modules.  

Strapping pins 1 and 2 of the jumper will set the module in SW 
mode and strapping pins 2 and 3 will set it in Auto Config mode. 

Auto: When set to Auto the module will, at power-up, check its 
internal flash memory to see if configuration information has 
been downloaded to it from a management module. If so it will 
use this as its running configuration. If there is no configuration 
in flash it will read the settings of the DIP switches and use those 
as its running configuration. 

SW: When set to SW (Switch), the module will, at power-up, 
read the settings of the DIP Switches and use those as it running 
configuration. It will ignore any configuration information in its 
flash memory. 

NOTE: The default jumper setting is Auto 

 

Содержание C-100-M2LC2

Страница 1: ...P N 5500306 15 Perle Fast Ethernet Media Converter Module Installation Guide C 100 XXXXX Unmanaged Module CM 100 XXXXX Managed Module...

Страница 2: ...nformation on the management options of the CM 100 module refer to the MCR MGT Module User s Guide Model Connector Mode Distance Wavelength C 100 M2xx2 CM 100 M2xx2 SC ST LC MM 2 km 1 2 mi 1310 nm C 1...

Страница 3: ...onverter Module into the chassis 5 Connect the fiber cable 6 Connect the copper cable Auto MDIX Jumper Note The factory settings for Auto MDIX will work for most installations but if there is a need t...

Страница 4: ...en set to Auto the module will at power up check its internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this as its running...

Страница 5: ...pper connection This will ensure the most optimal connection parameters will be in effect If the copper link partner does not support Auto negotiation the C 100 and CM 100 will default to 100 Mbps and...

Страница 6: ...a direct copper connection Standard Mode In this mode the links on the fiber and copper sides can be brought up and down independently of each other A loss of link on either the fiber or copper port...

Страница 7: ...h needs to be set Disabled The Media Converter Module will not monitor for or generate Far End Fault The following diagram is an illustration of the operation of this feature A Remote Media Converter...

Страница 8: ...ch setting is provided so that the attached device near end can negotiate its Ethernet parameters as if it was negotiating directly with the far end device The Pause switch setting on the Media Conver...

Страница 9: ...screwdriver remove the screw holding the face plate to the Chassis to reveal the slot opening 3 Set the jumpers and DIP switches on the Media Converter Module to the desired operating mode 4 Locate t...

Страница 10: ...dule and gently pull the module out 2 If not inserting a replacement Media Converter Module cover the opened slot with a face plate and secure the screw Installing the Duplex Fiber Cable Locate a 100B...

Страница 11: ...one Media Converter Module to another Media Converter switch fiber device Installing the Copper Cable Locate 100Base TX compliant copper cables with male RJ 45 connectors installed at both ends Conne...

Страница 12: ...r Test On Power is on module operating normally Blinking slowly the module is in loopback mode Blinking quickly the module has a hardware error LKF Fiber Link Activity On Fiber link present Blinking q...

Страница 13: ...nd automatically configures the connection Error Recovery In certain configurations and under specific conditions where the Media Converter Module brings down a link to convey status there is potentia...

Страница 14: ...unable to get full connectivity with all DIP switches in the UP position these methods are recommended for troubleshooting Method 1 1 If the Module is a CM 100 set the Auto Config jumper J6 to SW so...

Страница 15: ...verters should be lit Data should pass through the local converter over the fiber connection to the remote Media Converter At the remote Media Converter the data will be looped back and passed through...

Страница 16: ...1310 Min 20 Max 12 Min 31 Max 14 11 C 100 M2LC2 CM 100 M2LC2 MM TX 1310 RX 1310 Min 20 Max 12 Min 30 Max 14 10 C 100 S2SC20 CM 100 S2SC20 SM TX 1310 RX 1310 Min 18 Max 7 Min 32 Max 3 14 C 100 S2ST20...

Страница 17: ...32 Max 3 18 C 100 S1SC20D CM 100 S1SC20D SM TX 1550 RX 1310 Min 14 Max 8 Min 32 Max 3 18 C 100 S1SC40U CM 100 S1SC40U SM TX 1310 RX 1550 Min 8 Max 3 Min 33 Max 3 25 C 100 S1SC40D CM 100 S1SC40D SM TX...

Страница 18: ...h case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic environment this product may cause radio interferen...

Страница 19: ...ttp www perle com support_services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Que...

Отзывы: