3
22
User’s Handbook, TPD 1289E, Issue 2
6.3544 Series
How to start a cold engine with KBi or electrically operated Start Pilot
1
If necessary, renew the screw type canister. Ensure that the sealing washer remains in position when the
new canister is fitted. Each container has a safety valve.
2
If the engine is equipped with a manual stop control, ensure that it is in the "run" position.
3
Adjust the engine speed control to the maximum speed position.
4
Turn the start key to the "S" position (A) in order to engage the starter motor.
5
When the engine turns, press the starting aid button for a maximum period of 2 seconds. If the engine does
not start after the first 2 second application, keep the starter motor engaged. After 5 seconds, press the button
again for 2 seconds.
6
Allow the start switch to return to the "R" position, when the engine starts. Then adjust the engine speed
control to get an even idle speed. In certain conditions it is necessary to inject a little more fluid after the engine
has started, in order to ensure that the engine continues to run.
Warning!
KBi equipment must not be used with heater type cold starting aids such as the fuelled starting aid.
This document has been printed from SPI². Not for Resale
Содержание 6.3544 Series
Страница 6: ...vi This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 16: ...1 10 User s Handbook TPD 1289E Issue 2 6 3544 Series This document has been printed from SPI Not for Resale...
Страница 48: ...42 This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 52: ...46 This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 56: ...50 This page is intentionally blank This document has been printed from SPI Not for Resale...