8.
Connect the cable from the NEGATIVE
“
-
”
terminal
on the starter motor to the NEGATIVE
“
-
”
battery
terminal.
i02747977
Battery
Electrolyte
Level
-
Check
When
the
engine
is
not
run
for
long
periods
of
time
or
when
the
engine
is
run
for
short
periods,
the
batteries
may
not
fully
recharge.
Ensure
a
full
charge
in
order
to
help
prevent
the
battery
from
freezing.
If
batteries
are
correctly
charged,
the
ammeter
reading
should
be
very
near
zero,
when
the
engine
is
in
operation.
All lead-acid batteries contain sulfuric acid which
can burn the skin and clothing. Always wear a
face shield and protective clothing when working
on or near batteries.
1.
Remove the filler caps. Maintain the electrolyte
level to the
“
FULL
”
mark on the battery.
If the addition of water is necessary, use distilled
water. If distilled water is not available use clean
water that is low in minerals. Do not use artificially
softened water.
2.
Check the condition of the electrolyte with a
suitable battery tester.
3.
Install the caps.
4.
Keep the batteries clean.
Clean the battery case with one of the following
cleaning solutions:
• Use a solution of 0.1 kg (0.2 lb) baking soda
and 1 L (1 qt) of clean water.
• Use a solution of ammonium hydroxide.
Thoroughly rinse the battery case with clean
water.
i05424317
Battery
or
Battery
Cable
-
Disconnect
The battery cables or the batteries should not be
removed with the battery cover in place. The bat-
tery cover should be removed before any servic-
ing is attempted.
Removing the battery cables or the batteries with
the cover in place may cause a battery explosion
resulting in personal injury.
1.
Turn the start switch to the OFF position. Turn the
ignition switch (if equipped) to the OFF position
and remove the key and all electrical loads.
Note:
After the engine has stopped, allow 2 minutes
in order for the diesel exhaust fluid lines to be purged
before disconnecting the power.
2.
Disconnect the negative battery terminal. Ensure
that the cable cannot contact the terminal. When
four 12 V batteries are involved, 2 negative
connections must be disconnected.
3.
Remove the positive connection.
4.
Clean all disconnected connection and battery
terminals.
5.
Use a fine grade of sandpaper to clean the
terminals and the cable clamps. Clean the items
until the surfaces are bright or shiny. DO NOT
remove material excessively. Excessive removal
of material can cause the clamps to fit incorrectly.
Coat the clamps and the terminals with a suitable
silicone lubricant or petroleum jelly.
6.
Tape the cable connections in order to help
prevent accidental starting.
7.
Proceed with necessary system repairs.
8.
In order to connect the battery, connect the
positive connection before the negative connector.
SEBU9071-06
91
Содержание 2206F-E13TA
Страница 126: ......
Страница 128: ...SEBU9071 2020 Perkins Engines Company Limited All Rights Reserved 128 December 2020 ...