World-Wide Reduce Time Setting
Table 6
World-Wide Reduced Time Setting
Category 1 Fault (Tampering Dosing Interruption and Quality)
-
Normal operation
Level 1
Level 2
Level 3
Override
Inducement Time
First Occurrence
None
2.5 Hours
70 minutes
50 Percent torque
Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then
the repeat inducement time will be triggered.
The override can only be used once.
Inducement Time
Repeat Occurrence
None
5 minutes
5 minutes
50 Percent torque
Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
Inducement
None
None
None
Notification
None
Emission malfunction
lamp will be on solid
Emission malfunction
lamp will flash
Emission malfunction
lamp will flash
The stop lamp will
activate
Emission malfunction
lamp will flash
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
Table 7
World-Wide Reduced Time Setting
Category 2 Fault (Non-Tampering Dosing Interruption)
-
Normal operation
Level 1
Level 2
Level 3
Override
Inducement Time
First Occurrence
None
5 Hours
5 Hours
50 Percent torque
Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then
the repeat inducement time will be triggered.
The override can only be used once.
Inducement Time
Repeat Occurrence
None
None
1 Hour
50 Percent torque
Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
Inducement
None
None
None
Notification
None
Emission malfunction
lamp will be on solid
Emission malfunction
lamp will flash
Emission malfunction
lamp will flash
The stop lamp will
activate
Emission malfunction
lamp will flash
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
Table 8
World-Wide Reduced Time Setting
Category 3 Fault (Non-Tampering NOx Control Monitoring and Impeded EGR)
-
Normal operation
Level 1
Level 2
Level 3
Override
(continued)
SEBU9063-07
47