PS-1120 POWER SUPPLY OPERATION MANUAL 

t=8.0ms

FIRES

±30us

HOLD-OFF

200us

0

0

OUTPUT

VOLTAGE (V)

t=0

TUBE

TIME

CHARGE

TIME(t)

FIRES

TUBE

1/f

4.0 OPERATING 

CONDITIONS 

4.1 ENERGY 

RELATIONSHIPS 

At 24V input, 600V output, the unit delivers a minimum of 20 joules per second to 
the discharge capacitor.  Figure 3.1 shows typical charge rate values vs output 
voltage for four different DC inputs.   

 

Figure 3.  PS-1120 Typical Charge Rate Curves. 

 
The energy per discharge is given by the expression: 
 
 

J = Discharge energy 

 

C = Discharge capacitance 

 

V = Output voltage

 

 

 
Power is determined by P= J x Flashrate 
  
Long-term (1 minute or more) average 
power must be limited to 20 watts.  
Therefore, the sum total of the 
accumulated energy discharges 
(Joules) divided by the operating 
period (seconds) must be 

 20 watts. 

 
The flashtube may be fired any time 
after the charge time (see Fig. 4). 
 

Figure 4.  Output Voltage vs. Time 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание PS-1120

Страница 1: ...underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos I...

Страница 2: ...ptoelectronics 35 Congress St Salem MA 01970 USA Phone 978 745 3200 FAX 978 745 0894 Toll Free 800 950 3441 in USA only Website http www perkinelmer com opto E mail opto perkinelmer com Artisan Techno...

Страница 3: ...des Netzteils PS 1120 muss der Leistung aller damit verbundenen Komponenten angepasst werden Systemelemente Spannungen oder anderen Betriebsbedingungen auszusetzen die die Leistungswerte jener Kompone...

Страница 4: ...GE 8 FIGURES FIGURE 1 OPTIONAL PERKINELMER LITE PACS AND ACCESSORIES 2 FIGURE 2 OUTLINE AND MOUNTING DIMENSIONS 4 FIGURE 3 PS 1120 TYPICAL CHARGE RATE CURVES 5 FIGURE 4 OUTPUT VOLTAGE VS TIME 5 FIGURE...

Страница 5: ...ulated low ripple characteristics ensure excellent discharge repeatability 1 2 UNPACKING If the condition of the outer packaging suggests mishandling has occurred examine the unit for any signs of bre...

Страница 6: ...charge P Pmax Internal Discharge Cap PS 1120 1 0 1 F 10 PS 1120 2 0 25 F 10 PS 1120 3 0 5 F 10 Table 3 Electrical Output Trigger Trigger Voltage 175 15V Trigger Capacitor 0 1 F Max Pulse Rate 60 J wh...

Страница 7: ...utline and Mounting Dimensions PS 1120 POWER SUPPLY 3 25 82 6 6 32 UNC THREADED MOUNTING HOLE 0 23 5 8 MAXIMUM PENETRATION 5 85 43 4 57 2 2 25 17 5 0 69 92 2 3 63 BOTTOM VIEW 30 5 1 20 V OUT 1 71 J1 E...

Страница 8: ...ent DC inputs Figure 3 PS 1120 Typical Charge Rate Curves The energy per discharge is given by the expression J Discharge energy C Discharge capacitance V Output voltage Power is determined by P J x F...

Страница 9: ...should now flash at a low rate 5 2 INTERNAL ADJUSTMENT OF HV OUTPUT REFERENCE VOLTAGE The output voltage is programmed from 400V to 1KV by varying the VREF input from 4 0 to 10 0 volts The adjustment...

Страница 10: ...te Pac discharge circuit 4 Turn on the power supply 5 Set the high voltage by adjusting the reference voltage 6 Trigger as Required Figure 7 J1 Input Connector Figure 8 J2 Output Connector Cross Secti...

Страница 11: ...20 is to be stored for a prolonged period shipped to another location or returned to the factory for repair it should be repacked in the original packaging material If the packaging material has been...

Страница 12: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: