background image

 

 
 

                    

 

 

 
 

AIR PURIFICATION 

IONIZATION 

SANIFICATION

 

 

 

 

 

USER MANUAL AND 

MAINTENANCE 

 

 

 

 

Содержание SOLS Propacare JoyBion 400

Страница 1: ...AIR PURIFICATION IONIZATION SANIFICATION USER MANUAL AND MAINTENANCE ...

Страница 2: ...nologies for medical and industrial applications able to improve everyone s quality of life For over three decades Periso SA has specialized in the sectors of biomedicine energy industrial assembly and air treatment providing ground breaking and unique technological developments driven by a strong commitment to research and Swiss quality www periso ch ...

Страница 3: ...DEX 1 Benefits of the Technology page 4 2 Reference Directives and Regulations page 6 3 Warnings page 8 4 Instructions for Use page 9 5 Maintenance page 11 6 Technical Data page 16 7 Warranty page 17 8 Annotations page 18 ...

Страница 4: ...ological effects it entails and for the wide range of applications The technology of controlled bipolar ionization has a positive result for the health of people as it has a beneficial influence on human health stress and cognition Bipolar ionization is a well researched and utilized technology often found in schools hospitals airports restaurants and many commercial and industrial air systems The...

Страница 5: ...ter of 0 1 μm The activated carbon filter assists to remove VOC s as well as unpleasant odors from the environment Simultaneously the addition of positive ions and negative ions to the air in the room allows to neutralize and remove unwanted particles from the air revitalizing the air in a natural way The bipolar ionization metering system is the subject of an international patent by Periso SA and...

Страница 6: ...l aria EN 61000 6 3 Compatibilità elettromagnetica EMC Prescrizioni per gli elettrodomestici gli utensili elettrici e gli apparecchi similari Emissione EN 61000 6 1 Compatibilità elettromagnetica Requisiti di immunità per gli elettrodomestici gli utensili elettrici e gli apparecchi similari Immunità EN 61000 3 2 Compatibilità elettromagnetica EMC Limiti per le emissioni di corrente armonica EN 610...

Страница 7: ...me alla Direttiva 2014 35 UE relativa alla bassa tensione LVD directive alla Direttiva 2014 30 UE relativa alla compatibilità elettromagnetica EMC directive Direttiva RAEE 2012 19 UE sui Rifiuti di Apparecchiature Elettriche ed Elettroniche Directive on Waste Electrical and Electronic Equipment WEEE Direttiva ROHS 2011 65 CE sul divieto di utilizzo di determinate sostanze nelle apparecchiature Ele...

Страница 8: ...ating in high voltage Do not open or tamper with the ionizer while it is electrically powered and in operating mode Don t touch the electrodes see point 5 with device switched on Temperature Do not bring the ionizer devices near open flames or other high temperature sources Humidity Do not use the ionizing devices in excessively humid environments that may compromise correct operation of the devic...

Страница 9: ...n 400 should be placed at least 2 m away from televisions computers humidifiers and heat sources The JoyBion 400 can be put into operation immediately Its use is very simple a Insert the plug into a power outlet with voltage 220 240VAC 50 60 Hz b Position the ignition switch on the back of the device on I The device is now in stand by mode On the front of the device there is a LCD screen Red butto...

Страница 10: ... Speed Using the green button Ionize it is possible to turn off the ionization and the icon that appears on the screen is the following To activate ozone production use the red button Sanitize When ozone production is active the red LED lights up and the fan speed is automatically set to medium level The following icon appears on the screen The time also appears on the screen set using the red but...

Страница 11: ...g on Press to Open Electrostatic filter white should be changed 2 4 times per year and activated carbon filter black should be changed twice a year Failure to replace the filters entails the deposit of dust and dirt inside the device with possible risk of damage to the fan with increased noise emitted The environmental conditions in which the device is placed may be such that as to suggest the use...

Страница 12: ...move the upper cover by pressing on Press to Open Remove the grill containing the filters by lifting it sideways from the rear Remove the filters and replace the new ones by inserting them correctly and in the same order Grid containing filters ...

Страница 13: ...red circles in the previous image in the fins on the internal grid indicated by the red circles in the right image then lower the grid onto the base to ensure the spring lock Close the device by placing the top cover b Carbon fiber electrodes It is recommended not to obstruct the front of the appliance for a correct bipolar ionization emission ...

Страница 14: ...rder to avoid damages or electrode fibers bending In order to guarantee the efficiency of bipolar ionization it is necessary to remove the dust that can accumulate on the ionizing fibers 1 2 times per month Environments with higher levels of dust should clean the electrodes every 15 days c Glass Electrodes It is recommended once a year to clean the glass electrodes to remove the dust that has sett...

Страница 15: ...xing screws with an M3 wrench moving it forward a few millimeters and finally lifting it Clean the glass electrodes indicated by the red circle in the previous image and the motor without force on the blades with the supplied antistatic brush ESD taking care not to damage any component Repeat the operations in reverse to reassemble the appliance ...

Страница 16: ... 90 m2 Ionization strength 280 000 ions cm3 ventilation at min 390 000 ions cm3 ventilation at max For rooms up to 100 m2 Nominal Air flow 220m3 h at max Fan Tangential fan suitable for continuous operation ball bearings Filters 1 Electrostatic filter and 1 Activated carbon filter replaceable Dimensions 482 x 332 x 140 mm LxWxH Weight 8 kg Command Manual Installation Portable Measurements were mad...

Страница 17: ...se limited warranty conditions that is found to be defective within the scope of normal and appropriate use and are within the two 2 Year Warranty period Warranty claims must include receipt of purchase to validate warranty and optimally the original box of the unit for shipping Please have this information available when contacting customer service For warranty service in the European Union visit...

Страница 18: ...__________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ __________________________________...

Страница 19: ...______________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______...

Страница 20: ...www propa care 20 JoyBion 400_V01D_EN ...