AN
05/05/04
If nOE is connected to “L” and SEL is connected to “L”, Y+/Y- will connect to M+/M-. Figure 3 shows the signal path of
this connection.
SEL
nOE
Y+
Y-
X
H
Hi-Z
Hi-Z
L
L
M+
M-
H
L
D+
D-
Figure 3. Signal path of connection to M+/M-