background image

SPECIFICATIONS CONT.

5. Diode and Continuity

  Range 

Introduction  

Remark

The approximate forward voltage 

Open circuit voltage: about 1.5V

drop will be displayed

The built-in buzzer will sound if the   Open circuit voltage: about 0.5V

resistance is less than about 30Ω. 

Overload Protection: 250V DC/AC rms

For continuity test: When the resistance is between 30Ω and 100Ω, the buzzer may sound 

or may not sound. When the resistance is more than 100Ω, the buzzer won’t sound.

6. RESISTANCE (Auto Ranging)

  Range 

Resolution 

           Accuracy

  200Ω 

0.1Ω

  2KΩ 

1Ω 

  20KΩ 

10Ω 

±(1.5% of rdg + 3dgts)

  200KΩ  100Ω 
  2MΩ 

1KΩ 

  20MΩ 

10KΩ

 

Open Circuit Voltage: about 0.25V
Overload Protection: 250V DC/AC rms

7.BATTERY TEST

  Range 

Resolution 

     Internal Resistance

  12V 

10mV 

                1.2KΩ

  9V  

10mV 

900Ω

  1.5V 

1mV 

3KΩ

Measuring Voltage

1) Connect the BLACK test lead to the “COM” jack and the RED to the “INPUT” jack.
2) Set the function switch to V  or V  range.

Select auto range or manual range with the “RANGE” button.

3) In manual range, if the voltage magnitude to be measured is unknown 

beforehand, select the highest range.

4) Connect the test leads across the source or load to be measured.
5) Read LCD display. The polarity of the RED lead connection will be indicated 

when making a DC measurement.

NOTE:
a. In small range, the meter may display an unstable reading when the test leads 

 have not been connected to the load to be measured. It is normal and will not 
affect the measurements.

b. In manual range mode, when the meter shows the over range symbol “OL”, a 

higher range must to be selected.

c. To avoid damage to the meter, don’t measure a voltage which exceeds 600Vdc 

(for DC voltage measurement) or 600Vac (for AC voltage measurement).

Measuring Current
1) Connect the BLACK test lead to the “COM” jack. 
2) Set the range switch to desired µA  or mA  range. If the current magnitude to be 

measured is not known beforehand, set the ranges switch to the highest range 
position and then reduce it range by range until satisfactory resolution is obtained.

3) Select DC current measurement or AC current measurement with the “SELECT” Button.
4) Select auto range or manual range with the “RANGE” button. In manual range, if the 

current magnitude to be measured is not known beforehand, select the highest range.

5) Connect test leads in series with the circuit to be measured.
6) Read the reading on the display. For DC current measurement, the polarity of the red 

test lead connection will be indicated as well.

NOTE: When the display shows the over range symbol “OL”, a higher range must be selected.

OPERATION

OPERATION CONT.

Measure Resistance
1) Connect the BLACK test lead to the “COM” jack and the RED to the “INPUT” jack 

(Note: The polarity of the red test lead is positive “+”).

2) Set the range switch to Ω range

3) Select auto range or manual range with the “RANGE” button. In manual range, if 

the current magnitude to be measured is not known beforehand, select the 
highest range.

4) Connect the test leads across the load to be measured.
5) Read the reading on the display.

NOTE:

a. For resistance measurements >1MΩ, the meter may take a few seconds to 

stabilize reading. This is normal for high-resistance measurement.

b. When the input is not connected, i.e. at open circuit, the symbol “OL” will be 

displayed as an over range indicator.

c.

Before measuring in-circuit resistance, be sure that the circuit under test has all 
power removed and all capacitors are fully discharged.

Continuity Test
 1) Connect the BLACK test lead to the “COM” jack and the RED to the “INPUT” jack 

(Note: The polarity of the red test lead is positive “+”).

2) Set the range switch to   range
3) Press the “SELECT” Button to select continuity measurement mode, and the 

symbol “ ” will appear as an indicator.

4) Connect the test leads across the load to be measured.

5) If the circuit resistance is lower than about 30Ω, the built-in buzzer will sound.

Diode Test
1) Connect the BLACK test lead to the “COM” jack and the RED to the “INPUT” jack 

(Note: The polarity of the red test lead is positive “+”).

2) Set the range switch to   range

3) Press the “SELECT” Button to select continuity measurement mode, and the 

symbol “ ” will appear as an indicator.

4) Connect the red test lead to the anode of the diode to be tested and the black 

test lead to the cathode.

5) The meter will show the approximate forward voltage of the diode. If the 

connections are reversed, “OL” will be shown on the display.

Battery Test

1) Red lead to ”VΩmA”, Black lead to ”COM”

2) RANGE switch to desired ”BATT” position.

3) Connect red test lead to the battery’s negative.

4) The display will read the battery’s voltage.

Auto Power Off

If you don’t operate the meter for about 15 minutes, it will turn off automatically. To turn 

on it again, just rotate the range switch or press a button.
If you press the “SELECT” button and turns on meter, the automatic power-off function 
will be disabled.

Battery Replacement
If the sign “ ” appear on the display, it indicates battery should be replaced. Remove 
screws and open the back case, replace the exhausted battery with new batteries (Size 
AAA, 1.5V x2 or equivalent).

Fuse Replacement

Fuse rarely needs replacement and is blown almost always as a result of operator’s 

error. To replace the fuses, open the battery cover; replace the damaged fuse with a 
new fuse of the specified ratings.
Reinstall the battery cover and lock this cover.

Disposal
If you intend to dispose of this article, then please keep in mind that many of its 
components consist of valuable materials, which can be recycled. Please do not dispose 
it in the garbage, but check with your local council for recycling facilities in your area.

LIMITED LIFETIME WARRANTY

PERFORMANCE TOOL extends only the following warranties, and 
only to original retail purchasers. These warranties give specific legal 
rights. Except where prohibited by local law, the law of the State of 
Washington governs all warranties and all exclusions and limitations 
of warranties and remedies. There may be other rights which vary 
from state to state. 

PERFORMANCE TOOL warrants the product to be free from defects 
in materials and workmanship under normal use and service. A 
defective product may be returned for a free replacement within 90 
days from the date of purchase, provided that product is returned to 
place of purchase immediately after discovery of defect. These 
warranties shall be valid only when a sales receipt showing the date 
of purchase accompanies the defective product being returned. These 
warranties exclude blades, bits, punches, dies, bulbs, fuses, hoses, 
and other consumables which must be replaced under normal use 
and service. These warranties shall not apply to any product or part 
which is used for a purpose for which it is not designed, or which has 
been repaired or altered in any way so as to affect adversely its 
performance or reliability, nor shall these warranties apply to any 
product or part which has been subject to misuse, neglect, accident or 
wear and tear incident to normal use and service. 

PERFORMANCE TOOL does not authorize any other person to make 
any warranty or to assume any liability in connection with its products.  
Except for warranties of title and the limited express warranties set 
forth above, PERFORMANCE TOOL makes no express or implied 
warranties of any kind with respect to its products. In particular, 
PERFORMANCE TOOL makes no implied warranty of merchantability 
and no implied warranty of fitness for any particular purpose, except 
that for goods purchased primarily for personal, family or household 
use and not for commercial or business use, 

PERFORMANCE TOOL makes an implied warranty of merchantability 
(and, if otherwise applicable, an implied warranty of fitness for a 
particular purpose), but only for the particular qualities or 
characteristics, and for the duration, expressly warranted above. The 
laws on limitation of implied warranties may differ from state to state, 
so the above limitations may not apply in all cases. 

PERFORMANCE TOOL shall not be liable for consequential, 
incidental or special damages resulting from or in any manner related 
to any product, or to the design, use, or any inability to use the 
product. The sole and exclusive remedy for a defective product or part 
shall be the repair, or replacement thereof as provided above. The 
laws on limitation of remedies or on consequential, incidental or 
special damages may vary from state to state, so the above 
limitations may not apply in all cases. 

Отзывы: