Perfectaire PES5000 Скачать руководство пользователя страница 9

Fan 

Mode

Energy

  Saver

Follow 

   Me

CHECK FILTER FEATURE:

Press “Check

Filter” button

DO THIS:

FOLLOW ME FEATURE:

(on some models)

Light flashing

Displays

This feature is a reminder to clean the Air Filter for

more efficient operation. The LED (light) will illuminate after 

250 hours of operation. To reset after cleaning the filter, press

 

the “Check Filter” button and the light will go off.

NOTE: CHECK FILTER button

NOTE: FOLLOW ME indicator light

To activate the Follow Me feature, point the remote control 

towards the unit and press the “Follow Me” button. The remote 

displays the actual temperature at its location. The remote control 

will send this signal to the air conditioner every 3 minutes  

until the “Follow Me” button is pressed again.  If the unit does

not receive the “Follow Me” signal during any 7 minute interval,  

the unit will beep to indicate the Follow Me mode has ended. 

The actual temperature can be displayed at the unit by 

pressing the “Fan” only mode.  When in the “Cool” mode, the 

unit display indicates the set temperature.

This feature can ONLY be activated from the remote control. 
The remote control serves as a remote thermostat allowing for 
precise temperature control at its location.

AIR CONDITIONER FEATURES (CONTINUED)

Low

Auto

Med

High

TEMP/TIMER

Auto

Cool

Dry

Fan 

Fan 

Mode

On

Off

Sleep

Timer

Check

Filter

Energy

  Saver

Follow 

   Me

Low

Auto

Med

High

TEMP/TIMER

Auto

Cool

Dry

Fan 

Fan 

Mode

On

Off

Sleep

Timer

Check

Filter

High

Fan 

Fan 

Mode

Energy

  Saver

Follow 

   Me

DISPLAYS:

 The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one

  to the other, press and hold the Up and Down Temp/Timer buttons at the same time, for 3 seconds. 

Error Codes:
AS

 -  

Room temperature sensor error -

 Unplug the unit and

plug it back in. If error repeats, call customer service.

NOTE: 

In “Fan” only mode, unit will display “Lo” or “Hi”.

NOTE: 

If the unit breaks off unexpectedly 

due to power being cut, it will restart with

the previous function setting automatically   

when the power resumes.

   -     

Evaporator temperature sensor error -

 Unplug the unit 

and plug it back in. If error repeats, call customer service.

(“   ” is displayed as shown in left picture.)

HS

 -  

Electric heating sensor error

 

-

 Unplug the unit and 

plug it back in. If error repeats, call customer service.

NOTE: DISPLAYS

Shows the set temperature in “°C” or “°F” and the Auto-

timer settings. While on “Fan” only mode, it shows the 

room temperature.

ADDITIONAL THINGS YOU SHOULD KNOW

The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. After unit

is turned off, leave unit off for a minimum of 3 minutes before attempting to turn back on. This prevents 

overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time. 

 

 

 

Air Directional Louvers

HOW TO USE: 

The louvers will allow you to direct the air flow 

left or right throughout the room as needed. 

Move the levers from side to side until the desired

left/right direction is obtained. 

Lever

8

Содержание PES5000

Страница 1: ...efore using your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODELS PES5000 WINDOW AIR CONDITIONER USER MANUAL ...

Страница 2: ...act an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may require assistance with set up If the power cord is to be replaced replacement work should be performed by authorized personnel only Installatio...

Страница 3: ...cause explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause fire and electric shock Doing so may cause fire and electric shock Doing so may cause electric shock or fire If the power cord is damaged it must be replaced by the manufacturer or an authorized ...

Страница 4: ...r from unit contains contaminants and could cause illness Always insert the filters securely Clean filter AT LEAST once every two weeks NEVER drink water drained from air conditioner Unit and Circuit breaker fuse must be switched OFF when cleaning Do not place heavy objects on the power cord and always ensure that the cord is not compressed Use caution when unpacking and installing Sharp edges cou...

Страница 5: ...nt Device below for details In the event that the power supply cord is damaged it MUST be replaced by an authorized repairman Operation of Current Device 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out 3 Press the RESET button again you will notice a click as the button engages 4 The power...

Страница 6: ...or switching sounds Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation TURNS UNIT ON OR OFF SETS MODE ADJUSTS TEMPERATURE OR TIME SLEEP MODE ACTIVATES TIMER ADJUSTS TEMPERATURE OR TIME Low Auto Med High TEMP TIMER Auto Cool Dry Fan Fan Mode On Off Sleep Timer Check Filter Energy Saver SETS FAN SPEED CHECK FILTER RESET BUTTON ENERGY SAVER...

Страница 7: ...EMP TIMER Auto Cool Dry Fan Fan Mode On Off Sleep Timer Check Filter Energy Saver Follow Me TO SELECT THE OPERATING MODE Press the Mode button DO THIS To choose operating mode press the Mode button Each time you press the button a mode is selected in a sequence that goes from Auto Cool Dry and Fan The indicator light will be illuminated and remain on once the mode is selected The unit will automat...

Страница 8: ...minutes This new temperature will be maintained for 6 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again NOTE SLEEP button To operate on Fan only not available on all models Use this function only...

Страница 9: ... Off Sleep Timer Check Filter High Fan Fan Mode Energy Saver Follow Me DISPLAYS The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down Temp Timer buttons at the same time for 3 seconds Error Codes AS Room temperature sensor error Unplug the unit and plug it back in If error repeats call customer serv...

Страница 10: ...onditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils TOOLS YOU WILL NEED ...

Страница 11: ...ization and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained A Place unit on floor a bench or a table Hold the accordion panel in one hand and gently pull back the center to fill the open end See Fig 1 Fig 1 Lower sash must open sufficiently to allow a clear vertical opening of 13 inches 330 mm Side louvers and the rear of the AC must have clea...

Страница 12: ...against the window sill Fig 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back about 5 8 to 3 4 tilted about 3O to 4O downward to the outside After proper installation condensation should not drain from the overflow drain hole during normal use correct the slope otherwise B Extend the side panels out against the window frame Fig 6 wind...

Страница 13: ...r slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety sash lock Remove screws installed through frame and frame lock Close slide side panels into frame Keeping a firm grip on air conditioner raise sash and carefully remove Be c...

Страница 14: ...oth before wiping the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner after unit has dried completely If air conditioner will be stored during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Always store unit in upright position Winter ...

Страница 15: ... and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NOT TURN ON Reset circuit breaker Make sure there are not too many items ie lamps TV s etc working off the same breaker Check plug connection If plug is operating on an on off switch be sure that the swit...

Страница 16: ...e for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www perfectaire us ...

Отзывы: