Perfectaire PES5000 Скачать руководство пользователя страница 1

(5,000 BTU)

Before using your window air 
conditioner, please read this manual 
carefully and keep it for future 
reference, along with your receipt.

Your Source for Home Comfort

FOR MODELS:

PES5000

WINDOW

AIR CONDITIONER

USER MANUAL

Содержание PES5000

Страница 1: ...efore using your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODELS PES5000 WINDOW AIR CONDITIONER USER MANUAL ...

Страница 2: ...act an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may require assistance with set up If the power cord is to be replaced replacement work should be performed by authorized personnel only Installatio...

Страница 3: ...cause explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may cause fire and electric shock Doing so may cause fire and electric shock Doing so may cause electric shock or fire If the power cord is damaged it must be replaced by the manufacturer or an authorized ...

Страница 4: ...r from unit contains contaminants and could cause illness Always insert the filters securely Clean filter AT LEAST once every two weeks NEVER drink water drained from air conditioner Unit and Circuit breaker fuse must be switched OFF when cleaning Do not place heavy objects on the power cord and always ensure that the cord is not compressed Use caution when unpacking and installing Sharp edges cou...

Страница 5: ...nt Device below for details In the event that the power supply cord is damaged it MUST be replaced by an authorized repairman Operation of Current Device 1 Plug in the air conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button The RESET button will click as it pops out 3 Press the RESET button again you will notice a click as the button engages 4 The power...

Страница 6: ...or switching sounds Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation TURNS UNIT ON OR OFF SETS MODE ADJUSTS TEMPERATURE OR TIME SLEEP MODE ACTIVATES TIMER ADJUSTS TEMPERATURE OR TIME Low Auto Med High TEMP TIMER Auto Cool Dry Fan Fan Mode On Off Sleep Timer Check Filter Energy Saver SETS FAN SPEED CHECK FILTER RESET BUTTON ENERGY SAVER...

Страница 7: ...EMP TIMER Auto Cool Dry Fan Fan Mode On Off Sleep Timer Check Filter Energy Saver Follow Me TO SELECT THE OPERATING MODE Press the Mode button DO THIS To choose operating mode press the Mode button Each time you press the button a mode is selected in a sequence that goes from Auto Cool Dry and Fan The indicator light will be illuminated and remain on once the mode is selected The unit will automat...

Страница 8: ...minutes This new temperature will be maintained for 6 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again NOTE SLEEP button To operate on Fan only not available on all models Use this function only...

Страница 9: ... Off Sleep Timer Check Filter High Fan Fan Mode Energy Saver Follow Me DISPLAYS The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down Temp Timer buttons at the same time for 3 seconds Error Codes AS Room temperature sensor error Unplug the unit and plug it back in If error repeats call customer serv...

Страница 10: ...onditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils TOOLS YOU WILL NEED ...

Страница 11: ...ization and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained A Place unit on floor a bench or a table Hold the accordion panel in one hand and gently pull back the center to fill the open end See Fig 1 Fig 1 Lower sash must open sufficiently to allow a clear vertical opening of 13 inches 330 mm Side louvers and the rear of the AC must have clea...

Страница 12: ...against the window sill Fig 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back about 5 8 to 3 4 tilted about 3O to 4O downward to the outside After proper installation condensation should not drain from the overflow drain hole during normal use correct the slope otherwise B Extend the side panels out against the window frame Fig 6 wind...

Страница 13: ...r slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety sash lock Remove screws installed through frame and frame lock Close slide side panels into frame Keeping a firm grip on air conditioner raise sash and carefully remove Be c...

Страница 14: ...oth before wiping the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner after unit has dried completely If air conditioner will be stored during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Always store unit in upright position Winter ...

Страница 15: ... and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NOT TURN ON Reset circuit breaker Make sure there are not too many items ie lamps TV s etc working off the same breaker Check plug connection If plug is operating on an on off switch be sure that the swit...

Страница 16: ...e for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in PRC 877 365 6274 www perfectaire us ...