6
3.3
TEMPERATURES AND AMBIENT HUMIDITY
3.4
ELECTRICAL SPECIFICATIONS
3.4.1
CURRENT, VOLTAGE AND POWER RATINGS
3.4.2
COMMUNICATION SPECIFICATIONS
To see communication functions see chapter 5.1 Control and functions
3.4.3
ANALOG INPUTS AND OUTPUTS
Connections can be used either as inputs or outputs, depending on setup. Pump has 3 connectors: SET1, SET2
and SET3.
Operation outside recommended conditions may shorten pump lifetime and will void the
warranty.
Permitted ambient and media temperature:
Ambient temperature
[°C]
Medium temperature [°C]
Relative ambient humidity
min.
max.
Up to 25
-10
110
<95 %
30
-10
100
35
-10
90
40
-10
80
Electrical ratings
Pump
Rated voltage
Rated power
[W]
Rated current
[A]
Rated
current
(I
max
) [A]
Startup
Pro2(Z) xxx–6
230 VAC ± 15 %,
47-63Hz
Pumps operate at
reduced voltage
with limited power
(P=I
max
*U)
90
0,75
0,75
Built-in
startup
circuit
Pro2(Z) xxx-10
180
1,5
1,5
Pro2(D) 40–80
270
1,3
4,3
Pro2(D) 40–120
480
2,3
4,3
Pro2(D) 50–80
345
1,6
4,3
Pro2(D) 50–120
560
2,5
4,3
Pro2(D) 65–80
560
2,6
4,3
Electrical properties
Input voltage
–1 - 32 VDC
When used as input.
Output voltage
0 - 12 VDC
When used as an output. Max. 5 mA load on individual output.
Input impedance
~100 kΩ
0,5 mA additional load for most configurations.
Input sink current
0 - 33 mA
Common sink on COM, if used as output
Galvanic isolation
4 kV up to 1 s, 275 V permanent.