Perfect Sun 28 2F WOLFF Скачать руководство пользователя страница 3

30622-01A - Page 3

Turn bench over. Install hinge brackets 
to ends of bench such that the short 
boss engages the stud above the bolt 
hole, and the long boss engages the 
hole below the bolt hole. Secure using 
5/16” x 1” Allen-head bolts and 5/16” 
metal washers. Tighten bolt snug, then 
an additional half turn.

7

STUD

SHORT BOLT

Lift the canopy and hold it 
between the hinge brackets.

Place the bushings 
into hinge brackets.

8

Insert 5/16” x 1 1/2” bolts with nylon 
washers into both hinge brackets. Tighten 
bolts into the endcap threaded inserts 
until snug, then an additional half turn. 
Do not overtighten to avoid damaging 
threaded inserts.

10

The gas springs have a locking 
mechanism. Follow the directions 
below for the type you received.

11

With a helper holding the canopy 
open, align ends of gas spring ball 
joints with pivot studs and push 
into place. Be sure rod end is down 
as shown. DO NOT lower canopy 
until both gas springs are engaged!

12

Lift and lower canopy a few 
times to lubricate gas springs 
for optimum performance.

13

Plug the three-prong 220V AC 
power cord into a dedicated outlet 
(see 

Electrical Requirements

).

15

Type 1

Pry back the 
locking clip 
with a 

fl

 at 

screwdriver.

Type 2

Remove locking 
clip to install or 
remove gas spring.

PIVOT STUD

CAUTION

Failure to engage locking clips may 
result in the ball joints working loose, 
allowing the canopy to fall, which may 
result in damage to the unit and injury.

THREADED 

LOCKING RING

RECEPTACLE 

ON BENCH

CANOPY TO BENCH 

POWER CORD

REMOTE PORTS

WIRED 

REMOTE 

PORTS (RJ-22)

WIRELESS 

REMOTE 

PORT (RJ-11)

Connect the canopy to 
bench power cord to the 
bench receptacle. Align the 
terminals and 

fi

 rmly  push 

on until seated then tighten 
the threaded locking ring.

14

The unit is shipped with 
a Remote Control Bypass 
Plug installed. Your sunbed 
will not operate without 
either the bypass plug or a 
remote system connected. If 
remote operation is desired, 
see 

Remote Connections

.

16

Содержание 28 2F WOLFF

Страница 1: ... PS MAX Wolff Model PSM71 T12 100W BI PIN below or DARK TAN Wolff Model DT71 T12 100W BI PIN below PS EXTREME Wolff Model PSE71 T12 100W BI PIN below or DARK TAN PLUS Wolff Model DTP71 T12 100W BI PIN below Heraeus E400 HPT Philips Model HPA 400 30s or CosmoTech Model 23045 Facial Lamps THIS EQUIPMENT MUST BE EARTH GROUNDED This product is in conformity with performance standards for sun lamp prod...

Страница 2: ...s and star lock washers Make sure the threaded inserts point toward the stand legs and the wide end is toward what will be the floor 3 Attach the side skirts to the mounting brackets with two 10 32 x 1 2 screws and star lock washers from inside the skirt and into the brackets The rounded part of the side skirts points toward the front of the bed 4 Using 2 tree fasteners in each end attach the fron...

Страница 3: ...d end is down as shown DO NOT lower canopy until both gas springs are engaged 12 Lift and lower canopy a few times to lubricate gas springs for optimum performance 13 Plug the three prong 220V AC power cord into a dedicated outlet see Electrical Requirements 15 Type 1 Pry back the locking clip with a flat screwdriver Type 2 Remove locking clip to install or remove gas spring PIVOT STUD CAUTION Fai...

Страница 4: ...rface circuitry operates on 5 volts attempting to connect it to any higher voltages will damage the sunbed as well as void your warranty Scenario 1 T Max Manager Series with Complete Wireless Connect one G2 with Power Injector to the Manager and one G2 to each of the tanning beds Install as many beds as you like with this configuration Units that do not communicate with T Max will need an G2 with ...

Страница 5: ...Single Bed wired to T Max 3A In single sunbed installations the T Max 1A and 3A can offer the same control as the T Max Manager eliminating the need for a Man ager If you re using a 1A in this manner it must have a chip labelled master installed on its circuit board The remote control bypass plug must not be used in this configuration The 3A may be used as a mas ter with no modification After you ...

Страница 6: ... Start pulling from the middle of the profile CAUTION Be careful The edges of the acrylic shield may be sharp Operation A Timer display Displays remaining time B Timer button Turns bed on Timer display shows remaining time If a lesser time is desired press timer button until desired time is displayed C Stop button Interrupts tanning session D Face tanner button Units equipped with facial units onl...

Страница 7: ...pring contacts which enable the lamp to be removed easily Remove the old lamp and discard Install the new lamp using a clean cloth or paper towel Ensure that the lamp is firmly seated in the lamp holders Note Never take hold of the lamp such that your fingers are in contact with the lamp glass Finger oils will greatly reduce the lamp s opera tional life Step 3 Gently close the face tanner glass ca...

Страница 8: ...ply to residents of some states This Standard 18 Month War ranty gives you specific legal rights and you may have other rights which may vary from state to state Contact Perfect Sun for the authorized Service Center nearest you This war ranty is serial number specific and only applies to tanning units purchased through an authorized Perfect Sun Dealer This warranty is extended to the individual or...