  If  “NO  SD”  displayed  at  the  lower  left  corner  of 

screen, it indicates SD card is not installed.

  If  “FULL”  is  displayed  at  the  lower  left  corner  of 

screen, it indicates that SD card is full. 

1. Press “menu” key to enter into the mode of “menu”. 

2.  Select  the  image  storage  module  using  the  arrow 

keys. 

3. Press the “SELECT“ button to select the picture you 

want to view. 

4. Press the arrow keys to view other pictures.

 5. Press the SELECT button to view pictures. 

6.  Press  the  above  key  on  the  screen  will  display 

"Delete  photo  yes  no",  then  press  the  MENU  key  to 

delete the picture, Press "SELECT" to cancel. 

7.Press the MENU button to exit Review. 

Every  object  have  radiated  infrared  energy 

and the amount of infrared energy depends on 

t h e   o b j e c t   t e m p e r a t u r e   a n d   r a d i a t i o n 

coefficient  of  their  surface.  IR0002  can  sense 

the  infrared  energy  on  the  surface  of  object 

and  estimate  the  temperature  based  on  the 

sensed value of infrared energy. Many objects 

(e.g.  coated  metal,  wood,  water,  skin  and 

texture) can radiate energy, so it is easy to get 

t h e  a c c u r a t e  m e a s u r e d  v a l u e .  A s  t o  t h e 

surface  which  is  easy  to  radiate  energy  (high 

radiation  coefficient),  the  radiation  coefficient 

is greater than 90% (0.90). 

This  simple  rule  is  not  applicable  to  glossy 

s u r f a c e s  o r  c o a t e d  m e t a l  b e c a u s e  t h e i r 

radiation  coefficient  is  less  than  60%  (0.60). 

These materials are not easy to radiate energy 

s o  t h e y  a r e  c l a s s i fi e d  a s  l o w  r a d i a t i o n 

coefficient materials. 

To accurately measure the temperature of low 

radiation  coefficient  materials,  the  radiation 

coefficient  can  be  adjusted  for  more  accurate 

estimation of actual temperature. 

Emissivity  can  be  adjusted  from  0.10  to  1.00 

with  step  size  of  0.01,  with  default  value  at 

0.95. Correct setting of emissivity is important 

to  the  accurate  measurement  of  temperature. 

The surface emissivity has great impact on the 

measured temperature of our product. 

21. Emissivity of normal materials

Knowing    the  emissivity  of  measured  surface 

h e l p s   t o   g e t   m o r e   a c c u r a t e   r e s u l t   o f 

temperature, the following table can be used as 

a  reference  (This  is  for  reference  only  and  may 

not apply in all cases)

22.Maintenance 

Use wet cloth or liquid soap to clean the shell. 

Do not use abrasive compound or isopropyl 

alcohol or solvent to clean the shell or lens or 

window.

“ C o l o r   p a l e t t e ”   m e n u   c a n   c h a n g e   t h e 

representation  color  of  the  infrared  image 

displayed  on  the  screen  or  captured. A  number 

of  color  palettes  are  available  with  some  color 

palettes more applicable to some special areas. 

Gray-scale  color  palette  provides  balanced 

linear color, so it can help to fully reveal details. 

High-contrast  color  palette  can  emphasize  the 

displayed  color  and  is  applicable  to  hot-cold 

contrast situation. It is used to improve the color 

c o n t r a s t   o f   h i g h - t e m p e r a t u r e   a n d   l o w -

temperature.

Iron  red  and  rainbow  color  palettes  provide  a 

mixed high-contrast gray-scale color palette. 

The background temperature can be set between 0°C 

and  +36°C.  Set  the  temperature  compensation  for 

reflective  background  in  the  option  of  background. 

Over-hot or over-cold object may influence the object 

o r  t h e  s u r f a c e  t e m p e r a t u r e  a n d  m e a s u r e m e n t 

accuracy  of  measured  object.  When  the  radiation 

coefficient  of  the  surface  of  the  measured  object  is 

l o w,  t h i s  p h e n o m e n o n  i s  o b v i o u s .  U n d e r  m a n y 

s i t u a t i o n s ,  a d j u s t  t h e  t e m p e r a t u r e  o f  r e fl e c t i v e 

background to get the optimum measured result. 

  Turn  on  or  off  the  marking  of  spot  temperature.  If 

turning  on,  the  marking  of  spot  temperature  indicates 

that  the  hot  spot  or  cold  spot  in  the  screen  needs 

additional  appraisal.  If  turning  off,  it  indicates  that 

user can focus on the measured pixel per time. 

The product displays the temperature in unit of °C or 

°F.  

Under Time  Setting  menu,  press  “left”  or  “right” 

key  to  select  digit  for  adjust,  press  “up”  or 

“down”  key  to  increase  or  decrease  the  time 

value. After setting, press “menu” key to exit.

  The  measured  temperature  at  the  pixel  center 

i s  d i s p l a y e d  a t  t h e  u p p e r  l e f t  c o r n e r  a n d 

radiation  coefficient  is  displayed  at  the  upper 

right corner respectively. 

Move  the  product  until  hot  spot  or  cold  spot 

coincides  with  the  center  of  pixel.  Direct  the 

product  to  the  object  whose  temperature  is 

h i g h e r   o r   l o w e r   t h a n   t h e   s u r r o u n d i n g 

temperature  to  get  the  optimum  measured 

results. 

11. Time setting 

12. Measurement

13. Color palette 

19. Check internal storage

18. Image Capture and Storage 

17. Image mixing

16. Unit of temperature 

15. Marking of spot temperature

14. Temperature of reflective background

20. Notes on Emissivity

    0002 can store up to 25,000 images on the micro SD 

card. Press image capturing button and the symbol of 

“store photos yes no” will display on the screen. Press 

“MENU”  key  to  store  image.  Press  “SELECT”  key  to 

delete the captured image.

IR

    0002 can capture visible image of infrared image to 

accurately  display  the  temperature  distribution  of 

target  area,  and  allow  their  mixing  to  make  the 

understanding of infrared image become easier.
To use this mixing function, press “left” or “right” key to 

adjust the mixed image from 0% to 100%. 