background image

CONTENTS

P.1

1. Product overview

2. Considerations

3. Product description

4. Function setting operation

5. Measurement

6. New air quality level

7. Battery

8. Product specification

.................................................... 2

.......................................................... 3

............................................. 4 - 7

............................... 8 - 10

.......................................................... 11

............................................... 12

..................................................................... 12

...................................... 13 - 14

Содержание AQ9600

Страница 1: ...Air Quality Detector AQ9600 Instruction Manual ...

Страница 2: ...CONTENTS P 1 1 Product overview 2 Considerations 3 Product description 4 Function setting operation 5 Measurement 6 New air quality level 7 Battery 8 Product specification 2 3 4 7 8 10 11 12 12 13 14 ...

Страница 3: ...table for monitoring indoor environment of your house or office Measurements of air quality of roadways and natural environment can also be with this product 1 High measurement precision Combination of high quality electronic elements and advanced software 2 Stable performance Eliminates the need to stand still and stabilize the device 3 Easy to use Just a press the RUN button to start 4 Convenien...

Страница 4: ...able oil and gas ATEX or sites with strong electromagnetic interference Prevent dropping heavily impacting the device 2 No blocking or blowing hot air strong air to the air inlet during air sampling 3 Cleaning Use a dry cloth to wipe the device do not use a wet clothe or cleaning agent 4 Do not dismantle and remodel the product without authoriza tion This will void the warranty ...

Страница 5: ...rticle Counter RUN ENTER SHIFT BACK 1 2 3 5 6 4 7 8 2 3 4 1 Case Temperature and humidity detection port Open Sampling air inlet 6 7 8 5 LCD display screen Keys Exhaust port Battery 3 1 Product structure and appearance description ...

Страница 6: ... Battery level indication Counting unit Schematic diagram of concentration grade Display area of particle counting 8 9 10 11 7 Humidity Temperature Measuring object Weight unit Display area of particle weight calculation 3 2 LCD display description 1 9 8 3 10 11 4 5 6 7 2 ...

Страница 7: ...ce press RUN to start data sampling 2 Each sampling lasts for 50s During sampling other keys are disabled and cannot operate only power key can function Enter key ENTER 1 At the historical record mode press ENTER to confirm the page number of the selected pages 2 At the functional parameters mode 1 Press ENTER to enter function change 2 Press ENTER to save the changes ...

Страница 8: ... parameters mode change state used to increase by 1 switching unit and select yes or No Page down key 1 At the main interface press to enter the historical record the functional parameter 2 At the historical record mode used to decrease by 1 page down by one page 3 At the functional parameters mode change state used to decrease by1 switching unit and select yes or No Back key BACK 1 At historical ...

Страница 9: ...age number by 1 Pressing SHIFT key to select the page number 2 Pressing key to increase the value by 1 press key to decrease the value by 1 Functional Parameters Page Number piece L or ug m3 Change the particle unit 1 At the main interface press key twice to enter the functional parameter mode 2 Press ENTER key to enter the change state 3 Press SHIFT key to select piece L or ug m3 4 Press key or k...

Страница 10: ...e 6 Press SHIFT key to select the items to be changed 7 Press and key to increase or decrease the value by 1 respectively 8 Confirm and return to the main interface as above Temperature Unit C F 1 Enter the functional parameter mode as above 2 Press ENTER key to enter the change state 3 Press SHIFT key six times to select the items to be changed in temperature unit 4 Press key or key to select C F...

Страница 11: ...nge state 3 Press SHIFT key seven times to select the items to be changed in Restore factory set value 4 Press key or key to select Yes 5 Press ENTER key to confirm The screen will display restoring factory set value 6 Return to the main interface as above Users may also use the method to delete data record Function Type Function Items Function Setting Operation ...

Страница 12: ...itch on 2 Press RUN key at the main interface to enter the sampling state of 50 seconds 3 Do not operate the instrument while sampling 4 After sampling the result will be displayed on the screen 5 Users may enter functional parameter interface to set the particle unit so as to recognize the switching of measurement mode counting mode weighing mode ...

Страница 13: ...us pollution 0 35 35 75 75 115 115 150 150 250 250 New air quality standard Battery If the battery is too low it may cause the power to fail When the battery level shows please charge the battery in time 1 Use the original adapter and USB cable to charge the meter 2 Plug the USB cable into the USB charging port of the meter 3 Charging time is at least 2 hours 4 Unplug the USB cable after the batte...

Страница 14: ...d Sampling time Sampling method Typical precision Concentration unit Temperature range Typical precision Humidity range Typical precision Work temperature Working humidity Stored data Optoelectronic type Pumping type Laser diode 0 3um 2 5um 10 um 1L min 0 1000ug m3 1 ug Manual 50s Pumping type 20 Piece L ug m3 0 50 C 土 1 C 0 99 RH 2 RH 10 50 C 10 90 RH 999 sets ...

Страница 15: ...ower supply Startup current Working current Display method Screen size Screen resolution Weight Dimension 2 minutes no key operation Lithium ion Battery 120mA 200mA LCD value display Color backlight 2 8 inches 320 240 325g battery included 245 85 40mm ...

Страница 16: ...ur products and services please send us an email cs perfectprime com For B2B or project based application please send an email sales perfectprime com FOR MORE INFORMATION ABOUT PERFECTPRIME PLEASE VISIT OUR ABOUT US PAGE AND FEEL FREE TO BROWSE Scan QR Code for the Product Manual page Multi Language available for certain products Scan QR Code for the Youtube channel for video manual Scan QR Code t...

Страница 17: ...HORMES LIMITED cs perfectprime com G F UNIT 3 61 GLENTHORNE ROAD LONDON W6 0LJ UNITED KINGDOM 44 203 7695377 Retailer Email Address Telephone ...

Отзывы: