SAFETY & PRECAUTIONS

CONTINUED

CONTINUED

OPERATION INSTRUCTIONS

(Continued)

Emptying the condensate tank:

1. Shut off the air conditioner by pressing the power switch to the “O” position.
2. Locate the condensate tank.
3. Remove the condensate tank and empty the contents.
4. Re-install the condensate tank after emptying, making sure it is properly aligned.
5. Power on the unit. There is a 3-minute delay for the compressor to start. Normal operation will resume   
    after time delay has ended.
6. Empty the condensate tank before moving the air conditioner to avoid any spills.

ADJUSTMENT RANGE AND OPERATION OF THE AIR DIRECTION

• The cold air duct can rotate around 360 degrees
• The cold air duct can be moved up and down by about 150 degrees.

CONDENSATE TANK

ATTENTION:

  

When adjusting the air outlet angle of the cold 

air duct, please hold the elbow for adjustment. Do not directly 
hold the cold air duct for adjustment. 

ATTENTION:

  The compressor has a 3-minute safety delay function. After emptying the tank, there will be 

a 3-minute delay where only the fan will operate. After the 3-minutes have expired, the compressor will 

activate and normal operation will resume.

•  If the unit has not been operated for a long time, check the condensate tank before operating:
•   Remove the condensate tank from the air conditioner and confirm the float device inside the tank is 

intact. If no issues are found with the float device, re-install the condensate tank into the air conditioner, 

making sure everything is aligned.

•   Improper installation of the condensate tank may trigger the condensate alarm, unit malfunction, or 

condensate leakage.

Содержание PROAIRE SPOT6800

Страница 1: ...SPOT COOLER MODEL SPOT6800 OWNER S MANUAL...

Страница 2: ...7 TROUBLESHOOTING 8 IMPORTANT NOTE This spot cooler MUST be installed in accordance to all local governing codes and ordinances This spot cooler MUST be installed as specified by these instructions I...

Страница 3: ...n or around the appliance DO NOT operate or install your unit in a potentially explosive combustible or corrosive gas environment Keep your unit away from flammable materials and open flame DO NOT mov...

Страница 4: ...se Hz 115V 1Ph 60Hz Rated Current 7 1 A Indoor Air Flow 135 ft3 min 230m3 h Refrigerant Type R410a Refrigerant Amount 10 6 oz 300g Ambient Temperature Range 68 F 109 F 20 C 43 C Net Weight 56 lbs 25 5...

Страница 5: ...3 PRODUCT STRUCTURE Continued FRONT BACK POWER SWITCH CONDENSATE FULL INDICATOR COLD AIR OUTLET HOSE ASSEMBLY FILTER SCREEN DRAIN PORT HOT AIR EXHAUST HANDLE HANDLE CASTER FILTER CONDENSATE TANK...

Страница 6: ...2 Insert the locking tabs into the attachment channels Dent and turn until they lock into place Fig 1 A 3 Align the locking tabs on the elbow with the attachment channels Dent on the connection plate...

Страница 7: ...essor will not be operational and the air will not be cold If the thermal overload protection is frequently activated please find and eliminate the cause before using the machine WATER ALARM When the...

Страница 8: ...down by about 150 degrees CONDENSATE TANK ATTENTION When adjusting the air outlet angle of the cold air duct please hold the elbow for adjustment Do not directly hold the cold air duct for adjustment...

Страница 9: ...place obstacles in the front of the air inlet cold air duct and hot air exhaust MAINTENANCE CARE GUIDE Periodically clean the screen filter on this unit Dust and debris buildup will not allow proper...

Страница 10: ...unit into the wall outlet Ensure there is sufficient power at the wall outlet Have a professional or certified technician replace the fuse Clean the heat exchanger surface to allow for proper airflow...

Страница 11: ......

Страница 12: ...844 4PA AIRE 844 472 2473 support perfectaire us CANADA SUPPORT 877 997 2473 supportcanada perfectaire us www perfectaire us 5401 Dansher Road Countryside IL 60525 Printed in China 1220_M383...

Отзывы: