Figure 1. Digital Thermostat

Fan

Mode

Temperature

Selector

System

Mode

AbOUT ThE AIR CONDITIONER

This split system cooling unit has been designed and built 

to provide many years of safe and dependable comfort, 
providing it is properly installed and maintained. With 
regular maintenance, this unit will operate satisfactorily 
year after year. Abuse, improper use, and/or improper 
maintenance can shorten the life of the appliance and 
create unsafe hazards. A regular service and maintenance 
schedule should be established to ensure efficient and 
safe operation of the unit.

operAtInG InStrUCtIonS

Thermostat styles vary. Some models may not include 
the AUTO mode and others will have the AUTO in place 
of  the  HEAT  and  COOL.  Others  may  include  all  three. 

Please refer to the thermostat’s User Manual for detailed 
programming instructions.

The thermostat should be mounted about 5 feet above the 

floor on an inside wall and not on an outside wall or other 
location where its operation may be adversely affected by 
radiant heat from fireplaces, sunlight, or lighting fixtures, 
and convective heat from warm air registers or electrical 
appliances.

Cooling operation

1.  Set the thermostat’s system mode to COOL or AUTO 

and change the fan mode to AUTO. See Figure 1.

2.  Set the temperature selector to the desired 

temperature level. The outdoor fan, compressor, and 

blower motor will all cycle on and off to maintain the 
indoor temperature at the desired cooling level.

note: 

If the temperature level is re-adjusted, or the 

system mode is reset, the fan and compressor in the 
outdoor unit may not start immediately. A protective 
timer circuit holds the compressor and the outdoor fan 

off for approximately 5 minutes following a previous 

operation or the interruption of the main electrical 
power.

Heating operation

1.  Set the thermostat’s system mode to HEAT or AUTO 

and change the fan mode to AUTO. See Figure 1.

2.  Set the temperature selector to the desired 

temperature  level. The  optional  heating  equipment 

(furnace or electric heat) will cycle on & off to maintain 
the indoor temperature at the desired heating level.

operating the AC for Automatic Cooling & 
Heating

1.  Set the thermostat system mode to AUTO and the 

thermostat fan mode to AUTO. See Figure 1.

2.  Set the thermostat temperature selector to the 

desired  temperature  level.  The  thermostat  will 

maintain the desired temperature level by switching 
between either the outdoor cooling unit or the indoor 
heating unit (furnace or electric heat) automatically.

operating the Indoor Blower Continuously

The continuous indoor blower operation is typically used 

to circulate the indoor air to equalize a temperature 
unbalance due to solar loads, increased occupancy loads, 
or mechanical equipment operation. Set the thermostat 

fan  mode  to  ON  (Figure  1).  The  indoor  blower  starts 

immediately, and will run continually until the fan mode 

is reset to AUTO.

note:

 The continuous indoor blower operation can be 

obtained with the thermostat system mode set in any 

position, including OFF.

turning the Air conditioner off

Change the thermostat’s system mode to OFF and the fan 
mode to AUTO (See Figure 1). 

note:

 The system will not 

operate, regardless of the temperature selector setting.

Содержание JS4BD Series

Страница 1: ...ese instructions and on the unit Improper installation adjustment alteration service or maintenance can cause personal injury or property damage Refer to this manual For assistance or additional information consult a qualified installer or service agency Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance DO NOT DESTROY PLEASE READ CARE...

Страница 2: ...usted or the system mode is reset the fan and compressor in the outdoor unit may not start immediately A protective timercircuitholdsthecompressorandtheoutdoorfan off for approximately 5 minutes following a previous operation or the interruption of the main electrical power Heating Operation 1 Set the thermostat s system mode to HEAT or AUTO and change the fan mode to AUTO See Figure 1 2 Set the t...

Страница 3: ...ck for and remove any obstructions such as twigs sticks etc Inspect the condensate drain and outdoor coil at the beginning of each cooling season Remove any debris Air Filters WARNING Never operate the unit without a filter in the return air system Dust and lint in the return air can build up on the internal components resulting in loss of efficiency equipment damage and possible fire risk Inspect...

Страница 4: ...7095410 Replaces 7093020 Specifications illustrationssubjecttochangewithoutnoticeorincurringobligations 05 15 O Fallon MO Nortek Global HVAC LLC 2015 All Rights Reserved ...

Отзывы: