background image

5

 STEP 1:

PREPARE THE WINDOW

Lower sash must open sufficiently to allow a clear 

vertical opening (H) of the following size. (See Table 

1 on previous page.) Side louvers and the rear of the 

AC must have clear air space to allow enough  

airflow through the condenser for heat removal. 

The rear of the unit must be outdoors, not inside a 

building or garage.

MOUNTING HARDWARE:

3/4" (or 1/2")

Screws (7 pcs)

Lock Frame

(2 pcs)

Sash Lock

(1 pc)

Window 

Sash Seal 

Foam (1 pc)

Weather Stripping

10"x

3

/

4

"x

1

/

12

"

(5 pcs)

 STEP 2: 

PREPARE AIR CONDITIONER

A.

 Remove the air conditioner from the carton and 

place on a flat surface.

NOTE: 

The top rail hardware and Fig. A, Fig. B, and 

Fig. C are not applicable to the units 10,000 BTU/h or 

greater. For models less than 10,000 BTU/h, the top 

rail must be assembled. 

B.

  Remove top rail and insulation panels from the 

rear of the packaging material as shown in Fig. A. 

(Energy Star rated units only.)

TOP RAIL HARDWARE:

3/8" Screws

(4 pcs)

Top Rail

(1 pc)

Insulation 

Panels (2 pcs)

         

C.

  Align the hole in the top rail with those in the top of 

the unit as shown in Fig. B.

D.

 Secure the top rail to the unit with the 3/8″ screws 

as shown in Fig. C.

 STEP 3:

INSTALL THE ACCORDION PANELS

NOTE: 

Top rail and accordion panels on each side 

are offset to provide the proper pitch of 5/16″ to the 

rear. This is necessary for proper condensed water 

utilization and drainage. If you are not using the  

accordion panels for any reason, this pitch to the rear 

must be maintained.

B

. Slide the free end “   ” section of the panel directly 

into the cabinet as shown in Fig. 2. Slide the  

panel down. Be sure to leave enough space to slip 

the top and bottom of the frame into the rails on 

the cabinet.

" "

  

FIG. A

Packaging

Top Rail

Insulation Panels 

(for <10,000 Btu/h 

models only)

Insulation Panels 

(for ≥10,000 Btu/h 

models only)

FIG. B

FIG. C

FIG. 1

FIG. 2

A.

 Place unit on floor, a 

bench or a table. Hold the 

accordion panel in one hand 

and gently pull back the 

center to fill the open end. 

See Fig.1.

Содержание 5PAC10000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 5PAC10000 5PAC12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...or installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play wi...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Страница 7: ...is designed to install in standard double hung windows with opening widths of 23 to 36 inches 584 mm to 914 mm NOTE H vertical opening See table below TABLE 1 Model 5000 8000 Btu h 10000 12000 Btu h...

Страница 8: ...nergy Star rated units only TOP RAIL HARDWARE 3 8 Screws 4 pcs Top Rail 1 pc Insulation Panels 2 pcs C Align the hole in the top rail with those in the top of the unit as shown in Fig B D Secure the t...

Страница 9: ...ly H Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope B Extend the accordion...

Страница 10: ...se instructions STEP 6 1 After the unit is installed in the window measure the inner width of one of the accordion panels as shown in Fig 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 STEP...

Страница 11: ...rain holes or slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out REMOVING AC FROM WINDOW Turn AC off and disconnect power cord Remove sash seal f...

Страница 12: ...ollow the symbol for the functions you desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control TIMER ECO MODE FILTER On Off Auto Cool Dry Fan Follow me A...

Страница 13: ...lluminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO only AUTO COOLING and AUTO FAN modes TO OPERATE AUTO FEATURE W...

Страница 14: ...t throughout the room as needed Pivot horizontal louvers until the desired vertical up down direction is obtained Move the levers from side to side until the desired horizontal left right direction is...

Страница 15: ...lacing As an alternative to washing the filter vacuum the filter clean NOTE Never use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET...

Страница 16: ...he coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the roo...

Страница 17: ......

Страница 18: ......

Страница 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 20: ...Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User5PAC10...

Отзывы: