6

C

.  Once the panel has been installed on the side of 

the cabinet, make sure it sits securely inside the 

frame channel by making slight adjustments. Slide 

the top and bottom ends of the frame into the top 

and bottom rails of the cabinet. (Fig. 3) 

D.

 Slide the panel all the way in and repeat on the  

other side. (Fig 4)

NOTE:

 If storm window blocks AC, see Fig. 15, pg. 8.

 STEP 4: 

SECURE THE ACCORDION PANELS

A.

 Keeping a firm grip on the air conditioner, carefully 

place the unit into the window opening so the 

bottom of the air conditioner frame is against the 

window sill (Fig. 5). Carefully close the window 

behind the top rail of the unit. 

           

NOTE:

 Check that air conditioner is tilted back 

approximately 3/4″ to 1″ (Fig. 5 above) (tilted about 

3

°

 to 4

°

 downward to the outside). If, after proper 

installation, condensation does not drain from the 

overflow drain hole during normal use, adjust slope.

B.

  Extend the side panels out against the window 

frame (Fig. 6). 

 STEP 5: 

INSTALL SUPPORT BRACKET

A.

 Place the lock frame between the frame extensions 

and the window sill as shown in Fig. 7. Drive 3/4″  

(19 mm) or 1/2″ (12.7 mm) locking screws through 

the lock frame and into the sill. 

NOTE: 

To prevent window sill from splitting, drill 1/8″  

(3 mm) pilot holes before driving screws.

         

B.

  Drive 3/4″ (19 mm) or 1/2″ (12.7 mm) locking 

screws through frame holes into window sash  

(Fig. 8).

FIG. 3

FIG. 6

FIG. 7

FIG. 8

FIG. 4

FIG. 5

Top Left

Top Rail

Top Rail

Bottom Rail

Bottom Rail

Window 

Frame

Measure from the cabinet edge

Wooden Windows

INSIDE

OUTSIDE

Top Right

Approx. 3/4

 to 1

Содержание 4PAC6000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 4PAC6000 4PAC8000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...ller for installation of this unit The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play with the...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Страница 7: ...the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges...

Страница 8: ...pcs C Align the hole in the top rail with those in the top of the unit as shown in Fig B D Secure the top rail to the unit with the 3 8 screws as shown in Fig C NOTE For safety reasons all four 4 scr...

Страница 9: ...r is tilted back approximately 3 4 to 1 Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use...

Страница 10: ...ter the unit is installed in the window measure the inner width of one of the accordion panels as shown in Fig 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 STEP 6 2 Mark a line on one of t...

Страница 11: ...caulked or painted shut Accumulated rain water or condensation must be allowed to drain out FIG 15 Sash Storm window frame or other obstruction 1 min 38 mm Board thickness as required for proper pitch...

Страница 12: ...ng the unit This unit can be controlled by the unit control or with the remote control FOLLOW ME Indicator Energy Saver Mode Sets Mode Sleep Mode Turns Unit On or Off Set Fan Speed Adjusts Temp or Tim...

Страница 13: ...goes from AUTO COOL DRY and FAN The indicator light will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO...

Страница 14: ...ally when the power resumes AIR DIRECTIONAL LOUVERS Use the 4 way directional louvers to direct the air flow up or down and left or right throughout the room as needed Pivot horizontal louvers until t...

Страница 15: ...hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The c...

Страница 16: ...oil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room Re...

Страница 17: ......

Страница 18: ......

Страница 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Страница 20: ...Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_4PAC6...

Отзывы: